Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Outcomes of High Power Application in Catheter Ablation of Paroxysmal Atrial Fibrillation Guided by Unipolar Signal Modification.

12 janvier 2021 mis à jour par: Ahmad Abdelrady Abdelsalam Farghaly, Assiut University

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].

Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].

Aperçu de l'étude

Description détaillée

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].

Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].

The high-power short duration (HPSD) RF application applies to all RF energies delivered at more than 40 W [5]. Higher the power more is the resistive heating causing wider tissue injury [5]. The lesion size with HPSD is larger in width but lesser in depth compared to lower powers with longer duration [5]. In contrast, RF applications of lower power and longer duration result in larger dissipation of RF energies deep into the tissues due to conductive heating causing tissue destruction at greater depths [6]. Hence, there is a risk of collateral tissue damage [5].

HPSD ablation has been advocated as a means to minimize the risk of collateral organ damage as the lesions are smaller in depth. However, Maintaining a high power for a constant duration in the absence of a guide may not be the right strategy [5].

Unipolar waveform modification by complete elimination of the negative component may serve as a guide for HPSD ablation [5].

Type d'étude

Interventionnel

Inscription (Anticipé)

50

Phase

  • N'est pas applicable

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 80 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Paroxysmal atrial fibrillation

Exclusion Criteria:

  • Age< 18 or > 80 years old,
  • Atrium (LA) diameter > 50 mm,
  • The presence of a mechanical mitral valve prosthesis,
  • Left ventricular ejection fraction < 40%,
  • Abnormal thyroid function,
  • Contraindication to anticoagulant therapy,
  • Current malignancy,
  • Prior catheter or surgical AF ablation.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: Standard power application
Standard power application
Comparateur actif: High power application
Radiofrequency delivery was performed in a point-by point fashion and continuously (an inter-lesion distance of 6 mm) with 50 W and 70 W and the ablation time for each point is limited to 7s and repeated if needed till the Unipolar signal modification turn to complete positive R wave.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Ablation success at 6-month after the index procedure
Délai: 6 months
Ablation success is defined as no recurrence with no anti-arrhythmic drugs by taking history of symptoms from the patient and by Holter 48 Hours.
6 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Anticipé)

20 septembre 2021

Achèvement primaire (Anticipé)

1 octobre 2022

Achèvement de l'étude (Anticipé)

20 mars 2023

Dates d'inscription aux études

Première soumission

23 juin 2020

Première soumission répondant aux critères de contrôle qualité

24 juin 2020

Première publication (Réel)

25 juin 2020

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

13 janvier 2021

Dernière mise à jour soumise répondant aux critères de contrôle qualité

12 janvier 2021

Dernière vérification

1 janvier 2021

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • atrial fibrillation ablation

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner