Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials
Quantitative Clinical Evaluation of the Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials:a Self-control Study
研究概览
详细说明
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Fujian
-
Fuzhou、Fujian、中国、350004
- Fujian Medical University
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- with one mandibular first molar requiring crown restoration that have undergone root canal treatment;
- with complete permanent dentition;
Exclusion Criteria:
- with carious lesions, abrasions, attrition, erosions or any kind of tooth defects;
- with any kind of restorations in occlusal surfaces;
- with any sign of temporomandibular dysfunction.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:非随机化
- 介入模型:交叉作业
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Zirconia
10 crowns made of zirconia from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
实验性的:Celtra Duo
10 crowns made of Celtra Duo from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
实验性的:e.max CAD
10 crowns made of e.max CAD from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
实验性的:Lici UPCERA
10 crowns made of Lici from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
实验性的:Enamic
10 crowns made of Enamic from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
|
实验性的:Runci UPCERA
10 crowns made of Runci from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.
|
6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant. The six materials are as follows: ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China) |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
milling trueness(μm)
大体时间:1 week
|
the absolute 3D deviation of occlusal contact points before and after milling
|
1 week
|
|
postprocessing trueness(μm)
大体时间:1 week
|
the absolute 3D deviation of occlusal contact points before and after postprocessing
|
1 week
|
|
clinical trueness(μm)
大体时间:1 week
|
the absolute 3D deviation of occlusal contact points before and after occlusal adjustment
|
1 week
|
合作者和调查者
调查人员
- 首席研究员:Hao Yu、Fujian Medical University
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 2019028
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.