Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials

21 de abril de 2022 atualizado por: Hao Yu, Fujian Medical University

Quantitative Clinical Evaluation of the Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials:a Self-control Study

The aim of this clinic self-control study was to evaluate the trueness of occlusal contact affected by six ceramic materials during chairside fabricating process and offer recommendations for occlusal offset according to different ceramic materials in CEREC CAD/CAM design process.

Visão geral do estudo

Status

Concluído

Condições

Descrição detalhada

Ten participants were selected for this study. InCoris TZl(ZIR), Celtra Duo(CD), IPS e.max(EMA), UPCERA LICI (LC), Vita enamic(ENA), UPCERA RUNCI (RC) were used to produce crowns for everyone by CEREC chairside CAD/CAM system. The milling trueness, postprocessing trueness and clinical adjustment of occlusal contact were quantitatively analyzed by the ATOS high-precision scanner and Geomagic reverse engineering software.

Tipo de estudo

Intervencional

Inscrição (Real)

10

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Fujian
      • Fuzhou, Fujian, China, 350004
        • Fujian Medical University

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

20 anos a 30 anos (Adulto)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  1. with one mandibular first molar requiring crown restoration that have undergone root canal treatment;
  2. with complete permanent dentition;

Exclusion Criteria:

  1. with carious lesions, abrasions, attrition, erosions or any kind of tooth defects;
  2. with any kind of restorations in occlusal surfaces;
  3. with any sign of temporomandibular dysfunction.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Não randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Zirconia
10 crowns made of zirconia from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Celtra Duo
10 crowns made of Celtra Duo from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: e.max CAD
10 crowns made of e.max CAD from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Lici UPCERA
10 crowns made of Lici from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Enamic
10 crowns made of Enamic from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Runci UPCERA
10 crowns made of Runci from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
milling trueness(μm)
Prazo: 1 week
the absolute 3D deviation of occlusal contact points before and after milling
1 week
postprocessing trueness(μm)
Prazo: 1 week
the absolute 3D deviation of occlusal contact points before and after postprocessing
1 week
clinical trueness(μm)
Prazo: 1 week
the absolute 3D deviation of occlusal contact points before and after occlusal adjustment
1 week

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Hao Yu, Fujian Medical University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de novembro de 2019

Conclusão Primária (Real)

1 de julho de 2021

Conclusão do estudo (Real)

1 de agosto de 2021

Datas de inscrição no estudo

Enviado pela primeira vez

15 de abril de 2022

Enviado pela primeira vez que atendeu aos critérios de CQ

21 de abril de 2022

Primeira postagem (Real)

26 de abril de 2022

Atualizações de registro de estudo

Última Atualização Postada (Real)

26 de abril de 2022

Última atualização enviada que atendeu aos critérios de controle de qualidade

21 de abril de 2022

Última verificação

1 de abril de 2022

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 2019028

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever