Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials

21. April 2022 aktualisiert von: Hao Yu, Fujian Medical University

Quantitative Clinical Evaluation of the Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials:a Self-control Study

The aim of this clinic self-control study was to evaluate the trueness of occlusal contact affected by six ceramic materials during chairside fabricating process and offer recommendations for occlusal offset according to different ceramic materials in CEREC CAD/CAM design process.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Detaillierte Beschreibung

Ten participants were selected for this study. InCoris TZl(ZIR), Celtra Duo(CD), IPS e.max(EMA), UPCERA LICI (LC), Vita enamic(ENA), UPCERA RUNCI (RC) were used to produce crowns for everyone by CEREC chairside CAD/CAM system. The milling trueness, postprocessing trueness and clinical adjustment of occlusal contact were quantitatively analyzed by the ATOS high-precision scanner and Geomagic reverse engineering software.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

10

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Fujian
      • Fuzhou, Fujian, China, 350004
        • Fujian Medical University

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

20 Jahre bis 30 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  1. with one mandibular first molar requiring crown restoration that have undergone root canal treatment;
  2. with complete permanent dentition;

Exclusion Criteria:

  1. with carious lesions, abrasions, attrition, erosions or any kind of tooth defects;
  2. with any kind of restorations in occlusal surfaces;
  3. with any sign of temporomandibular dysfunction.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Nicht randomisiert
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Zirconia
10 crowns made of zirconia from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Celtra Duo
10 crowns made of Celtra Duo from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: e.max CAD
10 crowns made of e.max CAD from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Lici UPCERA
10 crowns made of Lici from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Enamic
10 crowns made of Enamic from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Experimental: Runci UPCERA
10 crowns made of Runci from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
milling trueness(μm)
Zeitfenster: 1 week
the absolute 3D deviation of occlusal contact points before and after milling
1 week
postprocessing trueness(μm)
Zeitfenster: 1 week
the absolute 3D deviation of occlusal contact points before and after postprocessing
1 week
clinical trueness(μm)
Zeitfenster: 1 week
the absolute 3D deviation of occlusal contact points before and after occlusal adjustment
1 week

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Hao Yu, Fujian Medical University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. November 2019

Primärer Abschluss (Tatsächlich)

1. Juli 2021

Studienabschluss (Tatsächlich)

1. August 2021

Studienanmeldedaten

Zuerst eingereicht

15. April 2022

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

21. April 2022

Zuerst gepostet (Tatsächlich)

26. April 2022

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

26. April 2022

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

21. April 2022

Zuletzt verifiziert

1. April 2022

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 2019028

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Zahndefekt

Abonnieren