Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials

21. april 2022 opdateret af: Hao Yu, Fujian Medical University

Quantitative Clinical Evaluation of the Occlusal Contact Trueness Affected by Six Chairside CAD/CAM Ceramic Materials:a Self-control Study

The aim of this clinic self-control study was to evaluate the trueness of occlusal contact affected by six ceramic materials during chairside fabricating process and offer recommendations for occlusal offset according to different ceramic materials in CEREC CAD/CAM design process.

Studieoversigt

Status

Afsluttet

Betingelser

Detaljeret beskrivelse

Ten participants were selected for this study. InCoris TZl(ZIR), Celtra Duo(CD), IPS e.max(EMA), UPCERA LICI (LC), Vita enamic(ENA), UPCERA RUNCI (RC) were used to produce crowns for everyone by CEREC chairside CAD/CAM system. The milling trueness, postprocessing trueness and clinical adjustment of occlusal contact were quantitatively analyzed by the ATOS high-precision scanner and Geomagic reverse engineering software.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

10

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Fujian
      • Fuzhou, Fujian, Kina, 350004
        • Fujian Medical University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

20 år til 30 år (Voksen)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  1. with one mandibular first molar requiring crown restoration that have undergone root canal treatment;
  2. with complete permanent dentition;

Exclusion Criteria:

  1. with carious lesions, abrasions, attrition, erosions or any kind of tooth defects;
  2. with any kind of restorations in occlusal surfaces;
  3. with any sign of temporomandibular dysfunction.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Ikke-randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Dobbelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Zirconia
10 crowns made of zirconia from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Eksperimentel: Celtra Duo
10 crowns made of Celtra Duo from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Eksperimentel: e.max CAD
10 crowns made of e.max CAD from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Eksperimentel: Lici UPCERA
10 crowns made of Lici from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Eksperimentel: Enamic
10 crowns made of Enamic from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Eksperimentel: Runci UPCERA
10 crowns made of Runci from 10 individual were milled, post-processed and occlusal adjusted in patients' mouth.

6 crowns made from 6 chairside ceramic materials were milled by CEREC MCXL-EF mode for mandibular first molar of each participant.

The six materials are as follows:

ZIR: InCoris TZI (Dentsply Sirona, York, PA), CD: Celtra Duo (Dentsply Sirona, York, PA), EMA: e.max CAD (ivoclar, Vivadent AG), LC: LiCi (UPCERA, China), ENA: Vita Enamic (Vita Zahnfabrik, Bad Sackingen, Germany) RC: RunCi (UPCERA, China)

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
milling trueness(μm)
Tidsramme: 1 week
the absolute 3D deviation of occlusal contact points before and after milling
1 week
postprocessing trueness(μm)
Tidsramme: 1 week
the absolute 3D deviation of occlusal contact points before and after postprocessing
1 week
clinical trueness(μm)
Tidsramme: 1 week
the absolute 3D deviation of occlusal contact points before and after occlusal adjustment
1 week

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Hao Yu, Fujian Medical University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. november 2019

Primær færdiggørelse (Faktiske)

1. juli 2021

Studieafslutning (Faktiske)

1. august 2021

Datoer for studieregistrering

Først indsendt

15. april 2022

Først indsendt, der opfyldte QC-kriterier

21. april 2022

Først opslået (Faktiske)

26. april 2022

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

26. april 2022

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

21. april 2022

Sidst verificeret

1. april 2022

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 2019028

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Tanddefekt

Kliniske forsøg med Chairside CAD/CAM ceramic materials for dental restoration

Abonner