Safety and Efficacy of the WaisFix100i for Intracapsular Femoral Fracture Fixation

January 9, 2009 updated by: OrthoMediTec

A Single Arm, Uni-Center, Prospective Clinical Investigation to Evaluate Safety and Efficacy of the WaisFix100i for Intracapsular Femoral Fracture Fixation

The purpose of this study is to determine the safety and efficacy of using WaisFix100i device for Intracapsular Femoral Fracture Fixation.

Study Overview

Detailed Description

Fractures of the neck of the femur represent an estimated cost to society that exceeds ten billion dollars annually in the USA only.

Fractures have been treated with immobilization, traction, amputation, and internal fixation throughout history. Immobilization by casting, bracing, or splinting a joint above and below the fracture was used for most long bone fractures.

Several studies have suggested that reduction and fixation of an Intracapsular fracture of the hip with multiple pins or screws is associated with a lower rate of morbidity and mortality than treatment with prosthetic replacement. With improved methods of fixation and a tendency toward earlier weight-bearing, internal fixation is believed to be a better mode of treatment for younger, more active patients.

On the other hand, the internal fixation procedure may result with number of possibilities for serious complications and biomechanical disadvantages, leading to the device failure. This led to a growing tendency to prefer total or partial hip replacement as the common treatment for intracapsular fracture, although the internal fixation is the favorable procedure in the professional literature.

OrthoMediTec has developed the WaisFix100i device, a new concept for Intracapsular Femoral Fracture Fixation and bone grafting using minimally invasive procedures. The WaisFix100i combines a new and unique Internal Triangular Cage nail fixator and three lag screws.

The Internal Triangular Cage is inserted into the femoral neck as a strong, solid beam structure to guide and hold the screws in place. The cage supplies the structure to hold the bone graft and screws at the fracture site.

The objectives of this single arm, multi-center, prospective study, are to evaluate the safety and efficacy of using the WaisFix100i device in intracapsular femoral fracture fixation surgery.

Study Type

Interventional

Enrollment (Anticipated)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Haifa, Israel
        • Carmel Medical Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

50 years to 75 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Male/Female with Intracapsular femoral fracture type Garden I-II and several III.
  2. Age 50 to 75.
  3. Subject able to comprehend and give informed consent for participation in this study.

Exclusion Criteria:

  1. Known active infectious disease.
  2. Terminal diseases
  3. Patients in high risk and/or acute cardio-vascular disease.
  4. Known cognitive disorder, psychiatric and/or neurological disease
  5. Physician objection.
  6. Age under 50 or above 75.
  7. Concurrent participation in any other clinical study
  8. Patients cannot understand or not willing to sign the informed consent.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: A
The WaisFix100i combines a new and unique Internal Triangular Cage nail fixator and three lag screws.
Other Names:
  • WaisFix100i
The WaisFix100i combines a new and unique Internal Triangular Cage nail fixator and three lag screws.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
The safety endpoint is measure by paucity incidence of treatment related major complications.
Time Frame: Study duration
Study duration

Secondary Outcome Measures

Outcome Measure
Time Frame
Efficacy endpoint is measure by the following: 1. A subject is scored a success if he had no revision surgery, hemi- arthroplasty or total hip replacement surgery by 12 months; 2. Time to functional recovery
Time Frame: Study duration
Study duration

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Marc Waisman, Dr., Carmel medical Center, Haifa Israel

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

September 1, 2007

Primary Completion (Anticipated)

March 1, 2008

Study Completion (Anticipated)

December 1, 2009

Study Registration Dates

First Submitted

August 26, 2007

First Submitted That Met QC Criteria

August 27, 2007

First Posted (Estimate)

August 28, 2007

Study Record Updates

Last Update Posted (Estimate)

January 12, 2009

Last Update Submitted That Met QC Criteria

January 9, 2009

Last Verified

February 1, 2008

More Information

Terms related to this study

Other Study ID Numbers

  • WF-01

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe