- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT01838343
Efficacy of Ultrasound to Guide Management During a Rapid Response Event
Rapid response team systems have been implemented in numerous hospitals throughout the world with the goal of improving the identification and safety of hospitalized patients who are clinically deteriorating. Despite their theoretical benefit, rapid response systems have not been proven in the medical literature to ultimately change outcomes.
The traditional physical exam is helpful in evaluating and treating unstable medical patients during these types of events but has significant limitations of deceased sensitivity and specificity of findings. Ultrasound is a known tool for more accurately assessing patients in shock and respiratory failure in the ICU by highly trained operators but to the investigators knowledge has not been studied in the setting of rapid response events on hospital wards by critical care fellows after focused training. The investigators aim to assess the impact of ultrasound performed by critical care fellows during rapid response events.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This is an randomized controlled trial to determine if portable critical care ultrasound use is feasible, if its findings change clinical decision making by critical care fellows and whether ultrasound can improve patient outcomes during rapid response events at Beth Israel Medical Center.
Patients for whom a rapid response has been called for cardiac or respiratory failure will be randomized to either have a bedside ultrasound performed by a critical care fellow at the time of rapid response or to undergo a bedside ultrasound only if clinically indicated and specifically requested by the RRT leader.
For all patients on whom a rapid response is called with shock or respiratory failure who are randomized to the intervention group, a designated ultrasound critical care fellow will document their ranked top 2 preliminary cause for either shock or respiratory failure on a data collection instrument (DCI). These clinical (i.e. pre-ultrasound) diagnoses will be based on history, physical exam and all ancillary testing available prior to ultrasound performance. Available ancillary testing will be documented.
An ultrasound exam will then be performed by the designated ultrasound fellow using a portable hand-carried unit (GE Vscan) and the findings documented on the same DCI. The GE Vscan will be used for all ultrasounds performed during this study. The ultrasound study will take approximately 5 -10 minutes and will not interfere with alternative evaluation or treatment modalities deemed to be necessary during the rapid response.
The critical care ultrasound fellow will then provide the RRT leader team with their 2 most likely post ultrasound diagnosis for shock and respiratory failure and then document these on the DCI. Any changes to management made as a result of the ultrasound exam, including all new ancillary tests and therapeutic interventions will be recorded.
At 72 hours following the initial event the ICU or general medical attending physician will be asked to document the "final" diagnosis as to the cause of the initial shock or respiratory failure. This "final" diagnosis will serve as the "gold standard" to allow the assessment of accuracy of the pre-ultrasound and post-ultrasound diagnoses.
Patients randomized to the standard care group will not have an ultrasound performed at the time of rapid response unless it is deemed medically necessary by the responding RRT leader or critical care fellow. This is the current practice approach at the investigators hospital where ultrasound is performed only when clinically indicated.
The study investigators will obtain all DCI's as well as the final diagnosis from the attending physician at 72 hours, and will enter this data into a database that will not contain any unique patient identifiers.
The patient's time in respiratory failure and time in shock will be recorded as primary outcome measures. Secondary outcomes of in-hospital mortality, utilization of CT scan and chest x-ray in the 24 hours following rapid response and hospital length of stay will also be recorded. Also measured will be variability in pre and post-ultrasound diagnosis as well as changes in management following ultrasound performance.
Study Type
Enrollment (Anticipated)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
New York
-
New York, New York, United States, 10003
- Beth Israel Medical Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria: Patients for whom a rapid response is called who have:
Hemodynamic instability as defined by:
- Systolic blood pressure less than 90 mmHg or less than 40 mmHg from previously established baseline
- Heart rate greater than 130 beats per minute
- Known elevated lactate above normal value.
- Hypercapnic or hypoxemic respiratory failure as judged by the responding critical care fellow.
Exclusion Criteria: Patients for whom a rapid response has been called who:
- Are not hemodynamically unstable and not in respiratory failure.
- Are hemodynamically unstable but who have an obvious source of bleeding to explain hemodynamic instability.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
No Intervention: No Ultrasound
Patients randomized to no ultrasound will get standard diagnostic and therapeutic interventions that are clinically indicated during the rapid response event.
|
|
|
Experimental: Ultrasound
Patients randomized to ultrasound will get a goal-directed ultrasound performed by a critical care fellow along with standard diagnostic and therapeutic interventions that are clinically indicated during the rapid response event.
|
Goal-directed ultrasound using a GE Vscan performed by a critical care fellow trained in ultrasonography.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time in shock
Time Frame: Immediately after rapid response
|
Time on vasopressors following the rapid response event and for 8 weeks thereafter.
|
Immediately after rapid response
|
|
Time in respiratory failure
Time Frame: From immediately after rapid response event and for 8 weeks thereafter.
|
Time period that the patient requires invasive or non-invasive mechanical ventilation.
|
From immediately after rapid response event and for 8 weeks thereafter.
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Mortality
Time Frame: During hospitaliztion or for 8 weeks thereafter.
|
Death during the hospitalization that the rapid response occured during.
|
During hospitaliztion or for 8 weeks thereafter.
|
|
Diagnosis variation following ultrasound
Time Frame: Immediately after ultrasound and for 1 day thereafter.
|
Agreement between pre-ultrasound and post-ultrasound diagnosis.
|
Immediately after ultrasound and for 1 day thereafter.
|
|
Utilization of chest x-ray
Time Frame: Following rapid response event and one day thereafter.
|
Frequency of chest x-ray performance will be measured during the 24 hours immediately following the rapid response event.
|
Following rapid response event and one day thereafter.
|
|
Utilization of CT scan
Time Frame: Following rapid response event for one day thereafter.
|
Frequency of CT scan performance will be measured during the 24 hours immediately following the rapid response event.
|
Following rapid response event for one day thereafter.
|
|
Length of stay
Time Frame: Following rapid response event and for 8 weeks thereafter.
|
Hospital length of stay following rapid response event.
|
Following rapid response event and for 8 weeks thereafter.
|
|
Management changes following ultrasound performance
Time Frame: Immediately following ultrasound and for one day thereafter.
|
Pre-ultrasound and post-ultrasound management will be documented.
|
Immediately following ultrasound and for one day thereafter.
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Estimate)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 218-12
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.