4D-MRI for Precision Medicine

April 30, 2026 updated by: G. Wilson Miller, MD, University of Virginia

Toward Precision Radiotherapy: Physiological Modeling of Respiratory Motion Based on Ultra-quality 4D-MRI

The purpose of this study is to develop new ways to make medical images of the lungs and liver of adults using a technique called four-dimensional magnetic resonance imaging (4D-MRI). This technique produces three-dimensional movies of the inside of the chest and abdomen while the patient is breathing. (The fourth dimension is time!)

This new way of medical imaging is being developed to help cancer patients undergoing radiation therapy. Radiation therapy is used to treat cancerous tumors. For radiation therapy to be effective, the precise size, shape, and location of the tumor within the body must be known. A particular difficulty for radiation treatment of lung and liver cancer is that the tumor moves during treatment because the patient is breathing. Therefore, tumor motion must also be incorporated into the treatment plan. This study aims to improve radiation treatment planning through better targeting and dose estimation based on 4D-MRI. Before this new imaging method can be used for radiation treatment planning, it must be tested in living, breathing volunteers.

Study Overview

Detailed Description

Radiotherapy for cancer has been a forerunner of personalized medicine, developing individualized treatments based on patient-specific anatomical information. Despite many advances in radiotherapy over the past decade, which have effectively enhanced local or loco-regional tumor control for many patients, there remains substantial room for improvement. The challenges for radiotherapy to further widen the therapeutic window in the era of precision medicine are mainly two-fold: (a) further improve radiation dose conformity to the defined target volume, and (b) adapt novel biological strategies for personalized treatment. Four-dimensional (4D) imaging and deformable image registration (DIR) are key tools in modern radiotherapy, playing critical roles in many recent advances, including 4D radiotherapy, adaptive radiotherapy, and treatment assessment. However, current 4D imaging and DIR technologies are facing significant challenges as the requirement for precision increases.

The current standard of 4D imaging in radiotherapy is 4D-CT. However, it has two major limitations preventing it from precision radiotherapy applications: (a) low soft-tissue contrast. 4D-CT is therefore not ideal for abdominal applications; (b) motion artifacts caused by irregular breathing. 4D-CT motion artifacts have been shown to cause errors in various radiotherapy applications, including motion measurement, target volume delineation, dose calculation, DIR, and lung ventilation calculation. 4D-MRI is an emerging 4D imaging technology for radiotherapy. It has superior soft-tissue contrast to 4D-CT and is therefore superb for abdominal imaging. Despite many recent advances in 4D-MRI, current 4D-MRI implementations have inadequate image quality for precision radiotherapy application due to at least one of the following deficiencies: low temporal and/or spatial resolutions, long image acquisition time, and suboptimal contrast in the lungs. Resulting 4D-MRI images lack sufficient anatomical details for clinical applications, which can adversely affect the performance of DIR. Current DIR techniques focus on morphological similarity but not on the physiological plausibility of the deformation. Studies have shown that an increased morphological similarity of the aligned data does not always imply increased registration accuracy. Therefore, more sophisticated approaches are desirable.

The investigators will take a systematic approach to address the aforementioned limitations of 4D imaging and deformable image registration (DIR) based on the development and cross-fertilization of two major techniques: ultra-quality 4D-MRI and physiological-based hybrid DIR. There are two parts of this research, comprising three main objectives:

Part 1. Technical development in healthy subjects: The investigators will extend their existing pulse sequence strategy for ultra-quality 3D MRI to enable ultra-quality 4D-MRI. Compared to 4D-CT and current 4D-MRI techniques, the proposed ultra-quality 4D-MRI technique offers the following advantages: (a) high spatial resolution (1.5 mm isotropic) with rich image features (e.g. vessel trees) in the whole torso; (b) high temporal pseudo-resolution (>20 phases/cycle); and (c) (nearly) free of motion artifacts.

• Objective 1: Develop an MRI pulse sequence and image reconstruction pipeline that generates images meeting these three design goals.

Part 2. Evaluation of 4D-MRI in a patient study: 4D-MRI will be compared with existing DIR and 4D-CT methods. There will be two classes of comparisons, each formulated as a separate objective:

  • Objective 2: Compare motion modelling based on 4D-MRI with deformable image registration (DIR) in healthy volunteers and cancer patients. An improved motion modeling method will be developed that is tailored for the ultra-quality 4D-MRI applications. The investigators hypothesize that a new motion modeling method based on 4D-MRI will outperform current DIR algorithms for respiratory motion estimation. This hypothesis will be tested by comparing the new method to five DIR algorithms which include a mix of commercial software and publicly available algorithms.
  • Objective 3: Compare 4D-MRI with 4D-CT in lung and liver cancer patients. The overall hypothesis of this objective is that the ultra-quality 4D-MRI provides better image quality than 4D-CT for motion management of radiotherapy in the lungs and the liver, especially in patients with irregular breathing.

Study Type

Observational

Enrollment (Estimated)

100

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Virginia
      • Charlottesville, Virginia, United States, 22908
        • Recruiting
        • University of Virginia
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 82 years (Adult, Older Adult)

Accepts Healthy Volunteers

Yes

Sampling Method

Probability Sample

Study Population

Up to 30 lung cancer patients, 30 liver cancer patients, and 40 healthy human volunteers will receive MRI examinations at the University of Virginia to directly measure respiratory motion in the thorax and abdomen. All subject populations will include roughly equal male and female representations. The subject populations will have minority and ethnic representation typical of the local population area that includes the University of Virginia. No specific racial or ethnic group will be excluded. All subjects must have the ability to understand the requirements of the study and must provide informed consent with a personal signature. No persons from vulnerable populations will be included in this study.

Description

Inclusion Criteria:The inclusion criteria for lung and liver cancer patients are:

  • Patient is 21 or older
  • Patient has primary or metastatic tumor(s) in the lungs or the liver
  • Diameter of the tumor(s) is less than 7 cm
  • Patient will receive radiation therapy (ordered by the treating Radiation Oncologist) as part of their treatment regimen
  • Patient will undergo a planning CT scan with tumor motion assessment (planning 4D-CT ordered by the treating Radiation Oncologist) as part of their treatment regimen
  • Patient has signed informed consent and is willing to comply with the 4D-MRI imaging protocol

The inclusion criteria for healthy volunteers are:

  • Subject is 18 or older
  • Subject has signed informed consent and is willing to comply with the 4D-MRI imaging protocol

Exclusion Criteria:

  • Any condition for which a MRI procedure is contraindicated including presence of metallic material in the body, such as pacemakers, non- MRI compatible surgical clips, shrapnel, etc.
  • Subjects who have difficulty lying flat on their back for extended periods of time
  • Patients with any serious/poorly controlled medical or psychological conditions that would complicate protocol compliance
  • Too large to adequately fit in the magnet bore or RF coils
  • Claustrophobia
  • Females who are pregnant or lactating
  • Presence of active or chronic infection

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Healthy
Healthy volunteers from the local community
Four-dimensional MRI of torso
Liver cancer
Patients undergoing radiotherapy for liver cancer
Four-dimensional MRI of torso
Lung cancer
Patients undergoing radiotherapy for lung cancer
Four-dimensional MRI of torso

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Image quality metrics in healthy volunteers
Time Frame: single imaging session, lasting up to 2 hours
General 4D-MRI image quality will be assessed based on signal-to-noise ratio, number of distinct images per breathing cycle, total necessary imaging time, and image quality index.
single imaging session, lasting up to 2 hours
Image quality metrics in cancer patients
Time Frame: single imaging session, lasting up to 2 hours
We hypothesize that our ultra-quality 4D-MRI methodology will outperform 4D-CT for motion management of radiotherapy in the lungs and the liver. We will test this hypothesis by comparing image quality based on tumor volume consistency, number of trackable landmarks, motion measurement accuracy, and image quality index.
single imaging session, lasting up to 2 hours
DVF errors in healthy volunteers and cancer patients
Time Frame: single imaging session, lasting up to 2 hours
We hypothesize that our motion modeling method based on 4D-MRI will outperform current DIR algorithms for respiratory motion estimation. We will test this hypothesis by comparing our method to five existing DIR algorithms, based on the magnitude error (Em) and the angular error (Ea) of the calculated deformation vector field (DVF).
single imaging session, lasting up to 2 hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: G. Wilson Miller, PhD, Univsersity of Virginia

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

November 5, 2020

Primary Completion (Estimated)

December 31, 2026

Study Completion (Estimated)

December 31, 2030

Study Registration Dates

First Submitted

November 23, 2020

First Submitted That Met QC Criteria

November 30, 2020

First Posted (Actual)

December 8, 2020

Study Record Updates

Last Update Posted (Actual)

May 6, 2026

Last Update Submitted That Met QC Criteria

April 30, 2026

Last Verified

April 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

YES

IPD Plan Description

Data acquired from cancer patients using the optimized 4D-MRI protocol will be used to construct digital phantoms for use by the radiotherapy research community to improve radiotherapy planning methods.

IPD Sharing Time Frame

Starting in approximately 2023, with no anticipated end date

IPD Sharing Access Criteria

undecided

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Lung Cancer

Clinical Trials on Magnetic Resonance Imaging

Subscribe