- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06242119
Clinical Application of the J-PET Scanner Prototype (JPET2Clinic)
Clinical Use of a J-PET Scanner Prototype Made of Plastic Scintilators
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Positron emission tomography (PET) is currently one of the basic techniques enabling molecular imaging. This concept means imaging at the level of biochemical processes. The J-PET scanner is the world's first positron tomograph based on plastic strip scintillators to measure the lifetime of the ortho-positronium (o-Ps) atom. This is a modular scanner, designed and installed at the Department of Experimental Particle Physics and Applications of the Jagiellonian University in Krakow. The J-PET scanner is based on technology patented in 2014 and 2016.
Current PET cameras possess remarkable sensitivity, enabling the detection of changes in chemical concentration as subtle as 1E-11 moles. This unprecedented sensitivity allows for the visualization of metabolic alterations, neurotransmitter imbalances, or receptor system dysfunctions at an early stage, often before the onset of clinical symptoms in various diseases. The PET technique relies on radioisotopes that emit positrons, which are the antimatter counterparts of electrons. PET cameras, tasked with monitoring positron distribution, employ detector systems that capture the radiation generated during positron-electron annihilation. This annihilation process occurs in the emission of gamma ray photons, which are detected by the appropriate detector arrays. The computer system particularly records only those events that simultaneously trigger two detectors, ensuring high spatial resolution and precise anatomical localization of the annihilation events. Notably, positron annihilation may be preceded by the formation of positronium, a transient, quasi-stable bound state comprising an electron and its antiparticle, the positron. Due to the mutual arrangement of spins, two states of the positron are distinguished.
- When the electron and positron spins are parallel (triplet state ↑↑); this arrangement is called ortho-positronium (o-Ps). o-Ps decays (annihilation occurs) after an average vacuum lifetime of 142 nanoseconds [ns]. Annihilation produces three gamma ray photons.
- When the spins of the electron and positron are antiparallel (singlet state ↑↓) - the system is called para-positronium (p-Ps). Annihilation produces two gamma-ray photons with an average vacuum lifetime of 125 picoseconds [ps], or 1,136 times shorter.
Distinct from conventional PET scanners employed in diagnostic imaging, the J-PET scanner boasts three remarkable features:
- Plastic Scintillation: unlike standard PET scanners that use expensive scintillation crystals, the J-PET scanner utilizes plastic scintillators, significantly lowering its cost and making it more affordable.
- Modular Design: J-PET's modular design allows for easy customization to fit different patient sizes and can be expanded to a whole-body PET scanner. This flexibility caters to a wide range of patient populations and diagnostic needs.
- Positronium Biomarker: J-PET expands the scope of PET imaging by introducing the detection and analysis of o-Ps.
Ad. 1. Conventional PET scanners use crystal detectors that detect gamma rays using the photoelectric effect. More expensive PET scanners use LSO, LYSO, or BGO crystals. New PET scanners use plastic detectors that detect gamma rays using Compton scattering. This allows for cheaper scanners with the same or better image quality.
Ad. 2. Thanks to the modular design and the use of strip scintillators, the time-of-flight (ToF) parameter is also used to improve image quality or obtain images of the same quality in a shorter examination because it reduces noise.
Ad.3. This capability opens up the possibility of utilizing a novel diagnostic biomarker that holds promising potential but remains underexplored in PET technology. Positronium imaging is applied only in the J-PET scanner. The PET technique uses radioisotopes that emit positron radiation (beta+). Traditional PET scanners image the distribution of gamma ray photons produced by the annihilation of an electron (e-) and a positron (e+). Annihilation may be preceded by the appearance of a positronium atom, which occurs in approximately 30-40% of all annihilations occurring in the patient body.
Working hypothesis:
The J-PET scanner is based on technology using plastic scintillators. If its clinical usefulness is proven, the development of this imaging method may significantly reduce the costs and increase the availability of PET/CT imaging.
Moreover, the J-PET tomograph allows us to determine a new diagnostic indicator, which is the lifetime of positronium atoms.
Aim of the study:
This study aims to demonstrate the clinical feasibility of PET scanners based on plastic scintillators, specifically investigating the performance of three-photon imaging and the use of positronium as a diagnostic biomarker. If the J-PET method allows to record the distribution of a chemical substance acting as a radiopharmaceutical with greater accuracy and - independently, it is possible to record the o-Ps lifetime depending on the biochemical composition of the environment, which is an additional parameter - not yet used in medical imaging.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Contact
- Name: Pawel Moskal, PhD
- Phone Number: +48-126644558 800-555-5555
- Email: p.moskal@uj.edu.pl
Study Contact Backup
- Name: Ewa Stepien, PhD
- Phone Number: +48-126644762 800-555-5555
- Email: e.stepien@uj.edu.pl
Study Locations
-
-
-
Krakow, Poland, 31-501
- Recruiting
- Department of Endocrinology and Nuclear Medicine, University Hospital in Krakow
-
Contact:
- Marta Opalinska, MD, PhD
- Phone Number: +48124001455
- Email: marta.opalinska@uj.edu.pl
-
Contact:
- Boguslaw Glowa, MD, PhD
- Phone Number: +48124001468
- Email: glowa@su.krakow.pl
-
Principal Investigator:
- Anna Sowa-Staszczak, MD, PhD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- The patient is referred for a PET/CT scan, in accordance with recognized indications for examining the entire body.
- Age over 18 years
- Informed, voluntary consent to participate in the study
Exclusion Criteria:
- Pregnant women, breastfeeding women
- People with a previously diagnosed allergy to radiopharmaceuticals
- Age under 18 years
- Lack of cooperation with the patient
- Lack of informed consent to participate in the study
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
J-PET group
The patient is referred for a PET/CT scan, in accordance with recognized indications for examining the brain or the entire body.
|
Diagnostic Test: Positron-Emission Tomography Imaging Examination of radiation distribution in the patient body after completing a routine examination on a PET diagnostic device.
J-PET prototype tests will be carried out in patients who have undergone a classic PET examination after administration of [18F]FDG), [68Ga]Ga-PSMA, [18F]choline or [68Ga]Ga-DOTATATE).
The duration of the additional exam will be approximately 20 minutes.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intraclass correlation coefficient (ICC)
Time Frame: Initial analyzes will last 12 weeks
|
ICC for Cancer Stage using the union for international cancer control (UICC) TNM (T= tumor, N= nodal stage, M = metastasis) System (8th Edition) for plastic scanner positron emission and computed tomography (J-PET/CT) exams compared to the standard of care (SOC) full-dose PET/CT as assessed by a panel of physicians
|
Initial analyzes will last 12 weeks
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Image quality
Time Frame: after 3 months following scan
|
Composite outcome assessing image quality in terms of tumour to background ratio (TBR) and signal to noise (SNR), defined as the reciprocal coefficient of variation (COV) for J-PET/CT compared to the standard of care PET/CT
|
after 3 months following scan
|
|
Subjective quality
Time Frame: after 3 months following scan
|
Image quality (subjective) as rated by five independent nuclear medicine physicians on a five-point Likert scale (1= unacceptable, 2=poor, 3=moderate, 4=good, 5=high) for J-PET/CT compared to the standard of care PET/CT
|
after 3 months following scan
|
|
Agreement
Time Frame: after 3 months following scan
|
Inter-reader agreement for the primary outcome (UICC cancer stage) shall be compared between J-PET/CT and the standard of care PET/CT
|
after 3 months following scan
|
|
Diagnostic accuracy
Time Frame: after 6 months following scan
|
Assessment of the positive predictive value (PPV) for J-PET/CT compared to the standard of care PET/CT for patients who undergo surgery or biopsy and where histopathological confirmation of true positive (TP) and false positive (FP) findings are available
|
after 6 months following scan
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Marta Opalinska, MD, PhD, Department of Endocrinology and Nuclear Medicine, University Hospital in Krakow
- Study Chair: Pawel Moskal, PhD, Jagiellonian University
- Study Director: Ewa Stepien, PhD, Jagiellonian University
Publications and helpful links
General Publications
- Moskal P, Dulski K, Chug N, Curceanu C, Czerwinski E, Dadgar M, Gajewski J, Gajos A, Grudzien G, Hiesmayr BC, Kacprzak K, Kaplon L, Karimi H, Klimaszewski K, Korcyl G, Kowalski P, Kozik T, Krawczyk N, Krzemien W, Kubicz E, Malczak P, Niedzwiecki S, Pawlik-Niedzwiecka M, Pedziwiatr M, Raczynski L, Raj J, Rucinski A, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien EL, Szczepanek M, Tayefi F, Wislicki W. Positronium imaging with the novel multiphoton PET scanner. Sci Adv. 2021 Oct 15;7(42):eabh4394. doi: 10.1126/sciadv.abh4394. Epub 2021 Oct 13.
- Moskal P, Stepien EL. Prospects and Clinical Perspectives of Total-Body PET Imaging Using Plastic Scintillators. PET Clin. 2020 Oct;15(4):439-452. doi: 10.1016/j.cpet.2020.06.009. Epub 2020 Jul 29.
- Moskal P, Kubicz E, Grudzien G, Czerwinski E, Dulski K, Leszczynski B, Niedzwiecki S, Stepien EL. Developing a novel positronium biomarker for cardiac myxoma imaging. EJNMMI Phys. 2023 Mar 24;10(1):22. doi: 10.1186/s40658-023-00543-w.
- Dadgar M, Parzych S, Baran J, Chug N, Curceanu C, Czerwinski E, Dulski K, Elyan K, Gajos A, Hiesmayr BC, Kaplon L, Klimaszewski K, Konieczka P, Korcyl G, Kozik T, Krzemien W, Kumar D, Niedzwiecki S, Panek D, Perez Del Rio E, Raczynski L, Sharma S, Shivani S, Shopa RY, Skurzok M, Stepien EL, Tayefi Ardebili F, Tayefi Ardebili K, Vandenberghe S, Wislicki W, Moskal P. Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators. EJNMMI Phys. 2023 Oct 11;10(1):62. doi: 10.1186/s40658-023-00572-5.
- Moskal P, Kisielewska D, Curceanu C, Czerwinski E, Dulski K, Gajos A, Gorgol M, Hiesmayr B, Jasinska B, Kacprzak K, Kaplon L, Korcyl G, Kowalski P, Krzemien W, Kozik T, Kubicz E, Mohammed M, Niedzwiecki S, Palka M, Pawlik-Niedzwiecka M, Raczynski L, Raj J, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien E, Wislicki W, Zgardzinska B. Feasibility study of the positronium imaging with the J-PET tomograph. Phys Med Biol. 2019 Mar 7;64(5):055017. doi: 10.1088/1361-6560/aafe20.
- Huang B, Li T, Arino-Estrada G, Dulski K, Shopa RY, Moskal P, Stepien E, Qi J. SPLIT: Statistical Positronium Lifetime Image Reconstruction via Time-Thresholding. IEEE Trans Med Imaging. 2024 Jun;43(6):2148-2158. doi: 10.1109/TMI.2024.3357659. Epub 2024 Jun 3.
Helpful Links
- Description Patent US8859973B2: Strip device and method for determining the location and time of reaction of the gamma quanta and the use of the device to determine the location and time of reaction of the gamma quanta in positron emission tomography
- P. Moskal, "Positronium Imaging," 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Manchester, UK, 2019, pp. 1-3
- Description Patent US9804274B2:Hybrid TOF-PET/CT tomograph comprising polymer strips made of scintillator material
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Urogenital Diseases
- Genital Diseases
- Pathologic Processes
- Genital Neoplasms, Male
- Urogenital Neoplasms
- Neoplasms by Site
- Neoplasms
- Genital Diseases, Male
- Prostatic Diseases
- Male Urogenital Diseases
- Neoplasms by Histologic Type
- Neoplasms, Glandular and Epithelial
- Adenocarcinoma
- Carcinoma
- Neuroectodermal Tumors
- Neoplasms, Germ Cell and Embryonal
- Neoplasms, Nerve Tissue
- Prostatic Neoplasms
- Prostatic Hyperplasia
- Hyperplasia
- Neuroendocrine Tumors
- Carcinoma, Neuroendocrine
Other Study ID Numbers
- MO 01.08.2023 J-PET
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.