Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent
Randomized Clinical Trial Comparing A Titanium-Nitride-Oxide Coated Stent With A Zotarolimus-Eluting Stent in Patients With Coronary Artery Disease
Přehled studie
Postavení
Podmínky
Detailní popis
Objectives: The purpose of this study is to compare the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) with a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) in a non-inferiority trial.
Design: Prospective, multi-center, randomized, non-inferiority trial to be conducted at 3 Swiss interventional cardiology centers. Patients will be randomized in a single-blind fashion (1:1 randomization) to either the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) or the Zotarolimus-Eluting Stent (EndeavorTm, Medtronic).
Study Population: Patients with symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction, who qualify for percutaneous coronary interventions
Antiplatelet Therapy: Aspirin 100 mg qd indefinitely; Clopidogrel 75 mg qd for 3 months
Enrollment: A total of 300 patients will be enrolled
All patients will undergo repeat angiography at 6-8 months.
All patients will be followed for up to 5 years.
Typ studie
Zápis (Aktuální)
Fáze
- Fáze 4
Kontakty a umístění
Studijní místa
-
-
-
Bern, Švýcarsko, 3010
- Department of Cardiology, University Hospital Bern
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
The following patients are eligible for inclusion
- Age ≥18 years
- Symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction
- Presence of one or more coronary artery stenoses >50% in a native coronary artery from 2.25 to 4.0 mm in diameter that can be covered with one or multiple stents;
- No limitation on the number of treated lesions, and vessels, and lesion length
Exclusion Criteria:
- Pregnancy
- Known intolerance to aspirin, clopidogrel, heparin, stainless steel, titan, zotarolimus or contrast material
- Inability to provide informed consent
- Currently participating in another trial before reaching first endpoint
- ST segment elevation myocardial infarction (STEMI)
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Singl
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Aktivní komparátor: Titanium Nitride Oxide Coated Stent
Stent
|
Titan2
|
|
Aktivní komparátor: Zotarohlimus Eluting Stent
Stent
|
Endeavor
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
In-stent late luminal loss
Časové okno: 6-8 months after stent implantation
|
6-8 months after stent implantation
|
Sekundární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
TLR, TVR, Death or MI, CV death or MI, CV death, Death, MI, Stent thrombosis, Stenosis, Restenosis
Časové okno: 30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
Spolupracovníci a vyšetřovatelé
Sponzor
Spolupracovníci
Vyšetřovatelé
- Vrchní vyšetřovatel: Stephan Windecker, MD, Department of Cardiology, University Hospital Bern, Bern, Switzerland
Publikace a užitečné odkazy
Obecné publikace
- Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, Pedrazzini G, Moccetti T, Wenaweser P, Togni M, Tuller D, Zbinden R, Seiler C, Mehilli J, Kastrati A, Meier B, Hess OM. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005 May 24;111(20):2617-22. doi: 10.1161/CIRCULATIONAHA.104.486647. Epub 2005 May 9.
- Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, Wu YP, Noll G, Leskosek B, Meier B, Hess OM; Working Group on Novel Surface Coating of Biomedical Devices (SCOL). Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001 Aug 21;104(8):928-33. doi: 10.1161/hc3401.093146.
- Pilgrim T, Raber L, Limacher A, Wenaweser P, Cook S, Stauffer JC, Garachemani A, Moschovitis A, Meier B, Juni P, Windecker S. Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention. 2015 Mar;10(11):1284-7. doi: 10.4244/EIJY15M01_04.
- Pilgrim T, Raber L, Limacher A, Loffel L, Wenaweser P, Cook S, Stauffer JC, Togni M, Vogel R, Garachemani A, Moschovitis A, Khattab AA, Seiler C, Meier B, Juni P, Windecker S. Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial. JACC Cardiovasc Interv. 2011 Jun;4(6):672-82. doi: 10.1016/j.jcin.2011.02.017.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- KEK237_06
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .