- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT00492908
Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent
Randomized Clinical Trial Comparing A Titanium-Nitride-Oxide Coated Stent With A Zotarolimus-Eluting Stent in Patients With Coronary Artery Disease
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
Objectives: The purpose of this study is to compare the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) with a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) in a non-inferiority trial.
Design: Prospective, multi-center, randomized, non-inferiority trial to be conducted at 3 Swiss interventional cardiology centers. Patients will be randomized in a single-blind fashion (1:1 randomization) to either the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) or the Zotarolimus-Eluting Stent (EndeavorTm, Medtronic).
Study Population: Patients with symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction, who qualify for percutaneous coronary interventions
Antiplatelet Therapy: Aspirin 100 mg qd indefinitely; Clopidogrel 75 mg qd for 3 months
Enrollment: A total of 300 patients will be enrolled
All patients will undergo repeat angiography at 6-8 months.
All patients will be followed for up to 5 years.
Undersøgelsestype
Tilmelding (Faktiske)
Fase
- Fase 4
Kontakter og lokationer
Studiesteder
-
-
-
Bern, Schweiz, 3010
- Department of Cardiology, University Hospital Bern
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
The following patients are eligible for inclusion
- Age ≥18 years
- Symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction
- Presence of one or more coronary artery stenoses >50% in a native coronary artery from 2.25 to 4.0 mm in diameter that can be covered with one or multiple stents;
- No limitation on the number of treated lesions, and vessels, and lesion length
Exclusion Criteria:
- Pregnancy
- Known intolerance to aspirin, clopidogrel, heparin, stainless steel, titan, zotarolimus or contrast material
- Inability to provide informed consent
- Currently participating in another trial before reaching first endpoint
- ST segment elevation myocardial infarction (STEMI)
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: Titanium Nitride Oxide Coated Stent
Stent
|
Titan2
|
|
Aktiv komparator: Zotarohlimus Eluting Stent
Stent
|
Endeavor
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
In-stent late luminal loss
Tidsramme: 6-8 months after stent implantation
|
6-8 months after stent implantation
|
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
TLR, TVR, Death or MI, CV death or MI, CV death, Death, MI, Stent thrombosis, Stenosis, Restenosis
Tidsramme: 30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
Samarbejdspartnere og efterforskere
Sponsor
Samarbejdspartnere
Efterforskere
- Ledende efterforsker: Stephan Windecker, MD, Department of Cardiology, University Hospital Bern, Bern, Switzerland
Publikationer og nyttige links
Generelle publikationer
- Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, Pedrazzini G, Moccetti T, Wenaweser P, Togni M, Tuller D, Zbinden R, Seiler C, Mehilli J, Kastrati A, Meier B, Hess OM. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005 May 24;111(20):2617-22. doi: 10.1161/CIRCULATIONAHA.104.486647. Epub 2005 May 9.
- Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, Wu YP, Noll G, Leskosek B, Meier B, Hess OM; Working Group on Novel Surface Coating of Biomedical Devices (SCOL). Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001 Aug 21;104(8):928-33. doi: 10.1161/hc3401.093146.
- Pilgrim T, Raber L, Limacher A, Wenaweser P, Cook S, Stauffer JC, Garachemani A, Moschovitis A, Meier B, Juni P, Windecker S. Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention. 2015 Mar;10(11):1284-7. doi: 10.4244/EIJY15M01_04.
- Pilgrim T, Raber L, Limacher A, Loffel L, Wenaweser P, Cook S, Stauffer JC, Togni M, Vogel R, Garachemani A, Moschovitis A, Khattab AA, Seiler C, Meier B, Juni P, Windecker S. Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial. JACC Cardiovasc Interv. 2011 Jun;4(6):672-82. doi: 10.1016/j.jcin.2011.02.017.
Datoer for undersøgelser
Studer store datoer
Studiestart
Primær færdiggørelse (Faktiske)
Studieafslutning (Faktiske)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- KEK237_06
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .