- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT00492908
Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent
Randomized Clinical Trial Comparing A Titanium-Nitride-Oxide Coated Stent With A Zotarolimus-Eluting Stent in Patients With Coronary Artery Disease
Przegląd badań
Status
Warunki
Szczegółowy opis
Objectives: The purpose of this study is to compare the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) with a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) in a non-inferiority trial.
Design: Prospective, multi-center, randomized, non-inferiority trial to be conducted at 3 Swiss interventional cardiology centers. Patients will be randomized in a single-blind fashion (1:1 randomization) to either the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) or the Zotarolimus-Eluting Stent (EndeavorTm, Medtronic).
Study Population: Patients with symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction, who qualify for percutaneous coronary interventions
Antiplatelet Therapy: Aspirin 100 mg qd indefinitely; Clopidogrel 75 mg qd for 3 months
Enrollment: A total of 300 patients will be enrolled
All patients will undergo repeat angiography at 6-8 months.
All patients will be followed for up to 5 years.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Faza 4
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Bern, Szwajcaria, 3010
- Department of Cardiology, University Hospital Bern
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
The following patients are eligible for inclusion
- Age ≥18 years
- Symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction
- Presence of one or more coronary artery stenoses >50% in a native coronary artery from 2.25 to 4.0 mm in diameter that can be covered with one or multiple stents;
- No limitation on the number of treated lesions, and vessels, and lesion length
Exclusion Criteria:
- Pregnancy
- Known intolerance to aspirin, clopidogrel, heparin, stainless steel, titan, zotarolimus or contrast material
- Inability to provide informed consent
- Currently participating in another trial before reaching first endpoint
- ST segment elevation myocardial infarction (STEMI)
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Pojedynczy
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Titanium Nitride Oxide Coated Stent
Stent
|
Titan2
|
|
Aktywny komparator: Zotarohlimus Eluting Stent
Stent
|
Endeavor
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
In-stent late luminal loss
Ramy czasowe: 6-8 months after stent implantation
|
6-8 months after stent implantation
|
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
TLR, TVR, Death or MI, CV death or MI, CV death, Death, MI, Stent thrombosis, Stenosis, Restenosis
Ramy czasowe: 30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
Współpracownicy i badacze
Sponsor
Współpracownicy
Śledczy
- Główny śledczy: Stephan Windecker, MD, Department of Cardiology, University Hospital Bern, Bern, Switzerland
Publikacje i pomocne linki
Publikacje ogólne
- Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, Pedrazzini G, Moccetti T, Wenaweser P, Togni M, Tuller D, Zbinden R, Seiler C, Mehilli J, Kastrati A, Meier B, Hess OM. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005 May 24;111(20):2617-22. doi: 10.1161/CIRCULATIONAHA.104.486647. Epub 2005 May 9.
- Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, Wu YP, Noll G, Leskosek B, Meier B, Hess OM; Working Group on Novel Surface Coating of Biomedical Devices (SCOL). Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001 Aug 21;104(8):928-33. doi: 10.1161/hc3401.093146.
- Pilgrim T, Raber L, Limacher A, Wenaweser P, Cook S, Stauffer JC, Garachemani A, Moschovitis A, Meier B, Juni P, Windecker S. Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention. 2015 Mar;10(11):1284-7. doi: 10.4244/EIJY15M01_04.
- Pilgrim T, Raber L, Limacher A, Loffel L, Wenaweser P, Cook S, Stauffer JC, Togni M, Vogel R, Garachemani A, Moschovitis A, Khattab AA, Seiler C, Meier B, Juni P, Windecker S. Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial. JACC Cardiovasc Interv. 2011 Jun;4(6):672-82. doi: 10.1016/j.jcin.2011.02.017.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- KEK237_06
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .