- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT00492908
Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent
Randomized Clinical Trial Comparing A Titanium-Nitride-Oxide Coated Stent With A Zotarolimus-Eluting Stent in Patients With Coronary Artery Disease
Обзор исследования
Статус
Условия
Подробное описание
Objectives: The purpose of this study is to compare the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) with a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) in a non-inferiority trial.
Design: Prospective, multi-center, randomized, non-inferiority trial to be conducted at 3 Swiss interventional cardiology centers. Patients will be randomized in a single-blind fashion (1:1 randomization) to either the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) or the Zotarolimus-Eluting Stent (EndeavorTm, Medtronic).
Study Population: Patients with symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction, who qualify for percutaneous coronary interventions
Antiplatelet Therapy: Aspirin 100 mg qd indefinitely; Clopidogrel 75 mg qd for 3 months
Enrollment: A total of 300 patients will be enrolled
All patients will undergo repeat angiography at 6-8 months.
All patients will be followed for up to 5 years.
Тип исследования
Регистрация (Действительный)
Фаза
- Фаза 4
Контакты и местонахождение
Места учебы
-
-
-
Bern, Швейцария, 3010
- Department of Cardiology, University Hospital Bern
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
The following patients are eligible for inclusion
- Age ≥18 years
- Symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction
- Presence of one or more coronary artery stenoses >50% in a native coronary artery from 2.25 to 4.0 mm in diameter that can be covered with one or multiple stents;
- No limitation on the number of treated lesions, and vessels, and lesion length
Exclusion Criteria:
- Pregnancy
- Known intolerance to aspirin, clopidogrel, heparin, stainless steel, titan, zotarolimus or contrast material
- Inability to provide informed consent
- Currently participating in another trial before reaching first endpoint
- ST segment elevation myocardial infarction (STEMI)
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Одинокий
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: Titanium Nitride Oxide Coated Stent
Stent
|
Titan2
|
|
Активный компаратор: Zotarohlimus Eluting Stent
Stent
|
Endeavor
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
In-stent late luminal loss
Временное ограничение: 6-8 months after stent implantation
|
6-8 months after stent implantation
|
Вторичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
TLR, TVR, Death or MI, CV death or MI, CV death, Death, MI, Stent thrombosis, Stenosis, Restenosis
Временное ограничение: 30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
30 days, 6-8 months, 1, 2, 3, 4 and 5 years
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Stephan Windecker, MD, Department of Cardiology, University Hospital Bern, Bern, Switzerland
Публикации и полезные ссылки
Общие публикации
- Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, Pedrazzini G, Moccetti T, Wenaweser P, Togni M, Tuller D, Zbinden R, Seiler C, Mehilli J, Kastrati A, Meier B, Hess OM. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005 May 24;111(20):2617-22. doi: 10.1161/CIRCULATIONAHA.104.486647. Epub 2005 May 9.
- Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, Wu YP, Noll G, Leskosek B, Meier B, Hess OM; Working Group on Novel Surface Coating of Biomedical Devices (SCOL). Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001 Aug 21;104(8):928-33. doi: 10.1161/hc3401.093146.
- Pilgrim T, Raber L, Limacher A, Wenaweser P, Cook S, Stauffer JC, Garachemani A, Moschovitis A, Meier B, Juni P, Windecker S. Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention. 2015 Mar;10(11):1284-7. doi: 10.4244/EIJY15M01_04.
- Pilgrim T, Raber L, Limacher A, Loffel L, Wenaweser P, Cook S, Stauffer JC, Togni M, Vogel R, Garachemani A, Moschovitis A, Khattab AA, Seiler C, Meier B, Juni P, Windecker S. Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial. JACC Cardiovasc Interv. 2011 Jun;4(6):672-82. doi: 10.1016/j.jcin.2011.02.017.
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- KEK237_06
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .