A Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

26. července 2016 aktualizováno: Yonsei University

A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

It is well-known that non-optimal stent implantation associated with under-expansion or incomplete strut apposition during percutaneous coronary intervention (PCI) leads to a higher incidence of restenosis and stent thrombosis. OCT-guided PCI with metallic stent has previously been shown to be safe and feasible, resulting in better clinical outcomes compared with angiography-only guided PCI. Everolimus-eluting bioabsorbable vascular scaffold (BVS; Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. BVS has a number of proposed advantages over current metallic stent technology. These include elimination of chronic sources of vessel irritation and inflammation, which can reduce the potential risk of late scaffold thrombosis after complete scaffold bioresorption. Although the current generation of the Absorb BVS have larger strut thickness of 150 μm compared with 80 μm of strut of Xience stent, the acute recoil of the polymeric device was similar to that of metallic stent. However, operators tented to use dilating devices less aggressively because of the concerns about limitation in elongation-at-break of polylactide. Previous studies reported 20-30% of under-expansion or malapposition with BVS, which would increase the risk of adverse events including late stent thrombosis. OCT-guidance may improve more optimized scaffold placement and also better outcomes. Therefore, investigators will compare OCT guidance and angiography-only guidance for PCI with BVS regarding incomplete scaffold apposition and neointimal scaffold coverage. Investigators are also going to compare these two strategies regarding clinical outcomes with verification of the cut-off value by OCT-acquired uncovered scaffold rate.

Přehled studie

Typ studie

Intervenční

Zápis (Aktuální)

13

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Seoul, Korejská republika, 120-752
        • Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

19 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  • Patients ≥ 19 years old
  • Patients with ischemic heart disease who are considered for coronary revascularization with PCI
  • Significant coronary de novo lesion (stenosis > 70% by quantitative angiographic analysis) treated by single BVS ≤ 25mm
  • Reference vessel diameter of 2.5 to 3.5 mm by operator assessment

Exclusion Criteria:

  • Myocardial infarction
  • Complex lesion morphologies such as aorta-ostial, unprotected left main, chronic total occlusion, graft, thrombosis, and restenosis
  • Reference vessel diameter <2.5 mm or >3.5 mm
  • Heavy calcified lesions (definite calcified lesions on angiogram)
  • Lesions requiring 2 or more BVS
  • Contraindication or hypersensitivity to anti-platelet agents or contrast media
  • Treated with any metallic stent or BVS within 3 months at other vessel
  • Creatinine level ≥ 2.0 mg/dL or ESRD
  • Severe hepatic dysfunction (3 times normal reference values)
  • Pregnant women or women with potential childbearing
  • Inability to follow the patient over the period of 1 year after enrollment, as assessed by the investigator
  • Inability to understand or read the informed content

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Aktivní komparátor: Angiography-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
Experimentální: OCT-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Percentage of uncovered scaffold struts
Časové okno: six months
Percentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT
six months

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Major cardiac and cerebrovascular adverse events (MACCEs)
Časové okno: until one year

Cardiac death, myocardial infarction, target vessel revascularization, stent thrombosis, cerebrovascular accident and major bleeding between OCT guidance vs. angiography-only guidance PCI until 12 months

*Major bleeding ; causing mortality, hypovolemic shock or severe hypotension requiring inotropes or surgery, intrapericardial with tamponade, significant disabling (e.g. intraocular bleeding leading to loss of vision), symptomatic intracranial haemorrhage, intraocular bleeding leading to loss of vision, hemoglobin drop ≥ 3g/dL, or requiring transfusion more than 2 units

until one year
Percentage of incomplete scaffold struts apposition
Časové okno: six months after stent implantation
Scaffold strut malapposition: Malapposition is defined by a clear seperation between the abluminal side of the strut and the vessel wall. As a result, scaffold malapposition is defined as the presence of any malapposed struts. percentage of malapposed struts (% malapposed strut) was the ratio of malapposed struts from total analyzable struts.
six months after stent implantation

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. června 2015

Primární dokončení (Aktuální)

1. května 2016

Dokončení studie (Aktuální)

1. června 2016

Termíny zápisu do studia

První předloženo

3. června 2015

První předloženo, které splnilo kritéria kontroly kvality

4. června 2015

První zveřejněno (Odhad)

9. června 2015

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Odhad)

27. července 2016

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

26. července 2016

Naposledy ověřeno

1. července 2016

Více informací

Termíny související s touto studií

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit