Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

A Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

tiistai 26. heinäkuuta 2016 päivittänyt: Yonsei University

A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

It is well-known that non-optimal stent implantation associated with under-expansion or incomplete strut apposition during percutaneous coronary intervention (PCI) leads to a higher incidence of restenosis and stent thrombosis. OCT-guided PCI with metallic stent has previously been shown to be safe and feasible, resulting in better clinical outcomes compared with angiography-only guided PCI. Everolimus-eluting bioabsorbable vascular scaffold (BVS; Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. BVS has a number of proposed advantages over current metallic stent technology. These include elimination of chronic sources of vessel irritation and inflammation, which can reduce the potential risk of late scaffold thrombosis after complete scaffold bioresorption. Although the current generation of the Absorb BVS have larger strut thickness of 150 μm compared with 80 μm of strut of Xience stent, the acute recoil of the polymeric device was similar to that of metallic stent. However, operators tented to use dilating devices less aggressively because of the concerns about limitation in elongation-at-break of polylactide. Previous studies reported 20-30% of under-expansion or malapposition with BVS, which would increase the risk of adverse events including late stent thrombosis. OCT-guidance may improve more optimized scaffold placement and also better outcomes. Therefore, investigators will compare OCT guidance and angiography-only guidance for PCI with BVS regarding incomplete scaffold apposition and neointimal scaffold coverage. Investigators are also going to compare these two strategies regarding clinical outcomes with verification of the cut-off value by OCT-acquired uncovered scaffold rate.

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Todellinen)

13

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

      • Seoul, Korean tasavalta, 120-752
        • Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

19 vuotta ja vanhemmat (Aikuinen, Vanhempi Aikuinen)

Hyväksyy terveitä vapaaehtoisia

Ei

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

Inclusion Criteria:

  • Patients ≥ 19 years old
  • Patients with ischemic heart disease who are considered for coronary revascularization with PCI
  • Significant coronary de novo lesion (stenosis > 70% by quantitative angiographic analysis) treated by single BVS ≤ 25mm
  • Reference vessel diameter of 2.5 to 3.5 mm by operator assessment

Exclusion Criteria:

  • Myocardial infarction
  • Complex lesion morphologies such as aorta-ostial, unprotected left main, chronic total occlusion, graft, thrombosis, and restenosis
  • Reference vessel diameter <2.5 mm or >3.5 mm
  • Heavy calcified lesions (definite calcified lesions on angiogram)
  • Lesions requiring 2 or more BVS
  • Contraindication or hypersensitivity to anti-platelet agents or contrast media
  • Treated with any metallic stent or BVS within 3 months at other vessel
  • Creatinine level ≥ 2.0 mg/dL or ESRD
  • Severe hepatic dysfunction (3 times normal reference values)
  • Pregnant women or women with potential childbearing
  • Inability to follow the patient over the period of 1 year after enrollment, as assessed by the investigator
  • Inability to understand or read the informed content

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Active Comparator: Angiography-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
Kokeellinen: OCT-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Percentage of uncovered scaffold struts
Aikaikkuna: six months
Percentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT
six months

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Major cardiac and cerebrovascular adverse events (MACCEs)
Aikaikkuna: until one year

Cardiac death, myocardial infarction, target vessel revascularization, stent thrombosis, cerebrovascular accident and major bleeding between OCT guidance vs. angiography-only guidance PCI until 12 months

*Major bleeding ; causing mortality, hypovolemic shock or severe hypotension requiring inotropes or surgery, intrapericardial with tamponade, significant disabling (e.g. intraocular bleeding leading to loss of vision), symptomatic intracranial haemorrhage, intraocular bleeding leading to loss of vision, hemoglobin drop ≥ 3g/dL, or requiring transfusion more than 2 units

until one year
Percentage of incomplete scaffold struts apposition
Aikaikkuna: six months after stent implantation
Scaffold strut malapposition: Malapposition is defined by a clear seperation between the abluminal side of the strut and the vessel wall. As a result, scaffold malapposition is defined as the presence of any malapposed struts. percentage of malapposed struts (% malapposed strut) was the ratio of malapposed struts from total analyzable struts.
six months after stent implantation

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus

Maanantai 1. kesäkuuta 2015

Ensisijainen valmistuminen (Todellinen)

Sunnuntai 1. toukokuuta 2016

Opintojen valmistuminen (Todellinen)

Keskiviikko 1. kesäkuuta 2016

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Keskiviikko 3. kesäkuuta 2015

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Torstai 4. kesäkuuta 2015

Ensimmäinen Lähetetty (Arvio)

Tiistai 9. kesäkuuta 2015

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Arvio)

Keskiviikko 27. heinäkuuta 2016

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Tiistai 26. heinäkuuta 2016

Viimeksi vahvistettu

Perjantai 1. heinäkuuta 2016

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Kliiniset tutkimukset Sepelvaltimotauti

Tilaa