- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT02466282
A Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold
A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold
Przegląd badań
Status
Warunki
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Seoul, Republika Korei, 120-752
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Patients ≥ 19 years old
- Patients with ischemic heart disease who are considered for coronary revascularization with PCI
- Significant coronary de novo lesion (stenosis > 70% by quantitative angiographic analysis) treated by single BVS ≤ 25mm
- Reference vessel diameter of 2.5 to 3.5 mm by operator assessment
Exclusion Criteria:
- Myocardial infarction
- Complex lesion morphologies such as aorta-ostial, unprotected left main, chronic total occlusion, graft, thrombosis, and restenosis
- Reference vessel diameter <2.5 mm or >3.5 mm
- Heavy calcified lesions (definite calcified lesions on angiogram)
- Lesions requiring 2 or more BVS
- Contraindication or hypersensitivity to anti-platelet agents or contrast media
- Treated with any metallic stent or BVS within 3 months at other vessel
- Creatinine level ≥ 2.0 mg/dL or ESRD
- Severe hepatic dysfunction (3 times normal reference values)
- Pregnant women or women with potential childbearing
- Inability to follow the patient over the period of 1 year after enrollment, as assessed by the investigator
- Inability to understand or read the informed content
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Angiography-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus.
PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
|
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus.
PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
|
|
Eksperymentalny: OCT-guidance
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus.
For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation.
OCT study should be checked at the final post-procedure and stent implantation is optimized.
|
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus.
For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation.
OCT study should be checked at the final post-procedure and stent implantation is optimized.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Percentage of uncovered scaffold struts
Ramy czasowe: six months
|
Percentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT
|
six months
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Major cardiac and cerebrovascular adverse events (MACCEs)
Ramy czasowe: until one year
|
Cardiac death, myocardial infarction, target vessel revascularization, stent thrombosis, cerebrovascular accident and major bleeding between OCT guidance vs. angiography-only guidance PCI until 12 months *Major bleeding ; causing mortality, hypovolemic shock or severe hypotension requiring inotropes or surgery, intrapericardial with tamponade, significant disabling (e.g. intraocular bleeding leading to loss of vision), symptomatic intracranial haemorrhage, intraocular bleeding leading to loss of vision, hemoglobin drop ≥ 3g/dL, or requiring transfusion more than 2 units |
until one year
|
|
Percentage of incomplete scaffold struts apposition
Ramy czasowe: six months after stent implantation
|
Scaffold strut malapposition: Malapposition is defined by a clear seperation between the abluminal side of the strut and the vessel wall.
As a result, scaffold malapposition is defined as the presence of any malapposed struts.
percentage of malapposed struts (% malapposed strut) was the ratio of malapposed struts from total analyzable struts.
|
six months after stent implantation
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 1-2015-0019
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Choroba wieńcowa
-
Peking University Third HospitalJeszcze nie rekrutacjaCentral Compartment Atopic Disease (CCAD)Chiny
-
Bambino Gesù Hospital and Research InstituteZakończonyCiężka otyłość dziecięca (BMI > 97° szt. -według wykresów BMI Centers for Disease Control and Prevention-) | Zmienione testy czynnościowe wątroby | Nietolerancja glikemicznaWłochy
-
Spero TherapeuticsZakończonyKompleks Mycobacterium Avium | Niegruźlicze Mycobacterium Pulmonary DiseaseStany Zjednoczone
-
Janssen Pharmaceutical K.K.ZakończonyOporna na leczenie Mycobacterium Avium Complex-lung Disease (MAC-LD)Tajwan, Japonia, Korea Południowa
-
Adelphi Values LLCBlueprint Medicines CorporationZakończonyBiałaczka z komórek tucznych (MCL) | Agresywna mastocytoza układowa (ASM) | SM w Assoc Clonal Hema Lineage Non-mast Cell Lineage Disease (SM-AHNMD) | Tląca się mastocytoza układowa (SSM) | Indolentna układowa mastocytoza (ISM) Podgrupa ISM w pełni zatrudnionaStany Zjednoczone