Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions

3. august 2026 opdateret af: Ahmed Mostafa Abdelfatah, Ain Shams University

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.

The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.

Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide & eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.

Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness

Studieoversigt

Status

Ikke rekrutterer endnu

Betingelser

Detaljeret beskrivelse

completely edentulous patients will be recruited.

Study procedures:

Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.

The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.

  • Intra oral scanners are:

    1. Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
    2. MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
  • Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.

For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

9

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Undersøgelse Kontakt Backup

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Barn
  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ja

Beskrivelse

Inclusion Criteria:

  • edentulous patients
  • last teeth extraction 6 months before the impression procedures

Exclusion Criteria:

  • un cooperative patients
  • Neuromotor disorders
  • Parkinsonism
  • Tremors

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Sundhedstjenesteforskning
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Digital impression of the mandibular edentulous arch
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
trueness assessment of impression techniques for mandibular edentulous arches
Tidsramme: 3 months
Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness in relation to desktop scanner. Root mean square of trueness in m.m will be reported.
3 months

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

15. juli 2026

Primær færdiggørelse (Anslået)

1. oktober 2026

Studieafslutning (Anslået)

15. oktober 2026

Datoer for studieregistrering

Først indsendt

14. juli 2026

Først indsendt, der opfyldte QC-kriterier

27. juli 2026

Først opslået (Faktiske)

3. august 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

4. august 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

3. august 2026

Sidst verificeret

1. august 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • OOC-8-25-6

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner