Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions

3 augustus 2026 bijgewerkt door: Ahmed Mostafa Abdelfatah, Ain Shams University

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.

The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.

Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide & eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.

Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness

Studie Overzicht

Toestand

Nog niet aan het werven

Conditie

Gedetailleerde beschrijving

completely edentulous patients will be recruited.

Study procedures:

Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.

The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.

  • Intra oral scanners are:

    1. Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
    2. MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
  • Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.

For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.

Studietype

Ingrijpend

Inschrijving (Geschat)

9

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Contact Back-up

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind
  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Ja

Beschrijving

Inclusion Criteria:

  • edentulous patients
  • last teeth extraction 6 months before the impression procedures

Exclusion Criteria:

  • un cooperative patients
  • Neuromotor disorders
  • Parkinsonism
  • Tremors

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Onderzoek naar gezondheidsdiensten
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Digital impression of the mandibular edentulous arch
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
trueness assessment of impression techniques for mandibular edentulous arches
Tijdsspanne: 3 months
Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness in relation to desktop scanner. Root mean square of trueness in m.m will be reported.
3 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

15 juli 2026

Primaire voltooiing (Geschat)

1 oktober 2026

Studie voltooiing (Geschat)

15 oktober 2026

Studieregistratiedata

Eerst ingediend

14 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

27 juli 2026

Eerst geplaatst (Werkelijk)

3 augustus 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

4 augustus 2026

Laatste update ingediend die voldeed aan QC-criteria

3 augustus 2026

Laatst geverifieerd

1 augustus 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • OOC-8-25-6

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren