Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions

maanantai 3. elokuuta 2026 päivittänyt: Ahmed Mostafa Abdelfatah, Ain Shams University

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.

The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.

Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide & eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.

Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness

Tutkimuksen yleiskatsaus

Tila

Ei vielä rekrytointia

Yksityiskohtainen kuvaus

completely edentulous patients will be recruited.

Study procedures:

Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.

The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.

  • Intra oral scanners are:

    1. Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
    2. MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
  • Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.

For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

9

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

Tutki yhteystietojen varmuuskopiointi

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Lapsi
  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Joo

Kuvaus

Inclusion Criteria:

  • edentulous patients
  • last teeth extraction 6 months before the impression procedures

Exclusion Criteria:

  • un cooperative patients
  • Neuromotor disorders
  • Parkinsonism
  • Tremors

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Terveyspalvelututkimus
  • Jako: Ei käytössä
  • Inventiomalli: Yksittäinen ryhmätehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Digital impression of the mandibular edentulous arch
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
trueness assessment of impression techniques for mandibular edentulous arches
Aikaikkuna: 3 months
Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness in relation to desktop scanner. Root mean square of trueness in m.m will be reported.
3 months

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Keskiviikko 15. heinäkuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Torstai 1. lokakuuta 2026

Opintojen valmistuminen (Arvioitu)

Torstai 15. lokakuuta 2026

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Tiistai 14. heinäkuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 27. heinäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Maanantai 3. elokuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Tiistai 4. elokuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 3. elokuuta 2026

Viimeksi vahvistettu

Lauantai 1. elokuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa