Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions

3 de agosto de 2026 actualizado por: Ahmed Mostafa Abdelfatah, Ain Shams University

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.

The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.

Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide & eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.

Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Descripción detallada

completely edentulous patients will be recruited.

Study procedures:

Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.

The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.

  • Intra oral scanners are:

    1. Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
    2. MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
  • Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.

For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

9

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Descripción

Inclusion Criteria:

  • edentulous patients
  • last teeth extraction 6 months before the impression procedures

Exclusion Criteria:

  • un cooperative patients
  • Neuromotor disorders
  • Parkinsonism
  • Tremors

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Investigación de servicios de salud
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Digital impression of the mandibular edentulous arch
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
trueness assessment of impression techniques for mandibular edentulous arches
Periodo de tiempo: 3 months
Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness in relation to desktop scanner. Root mean square of trueness in m.m will be reported.
3 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

15 de julio de 2026

Finalización primaria (Estimado)

1 de octubre de 2026

Finalización del estudio (Estimado)

15 de octubre de 2026

Fechas de registro del estudio

Enviado por primera vez

14 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

27 de julio de 2026

Publicado por primera vez (Actual)

3 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

4 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

3 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir