Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions
the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.
The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.
Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide & eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.
Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
completely edentulous patients will be recruited.
Study procedures:
Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.
The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.
Intra oral scanners are:
- Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
- MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
- Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.
For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiekontakt
- Navn: Ahmed Mohamed, MD
- Telefonnummer: 01111191337
- E-post: ahmedmostafa@dent.asu.edu.eg
Studer Kontakt Backup
- Navn: Ahmed Mohamed, MD
- Telefonnummer: 01111191337
- E-post: ahmedmohameddodo85@gmail.com
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- edentulous patients
- last teeth extraction 6 months before the impression procedures
Exclusion Criteria:
- un cooperative patients
- Neuromotor disorders
- Parkinsonism
- Tremors
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Helsetjenesteforskning
- Tildeling: N/A
- Intervensjonsmodell: Enkeltgruppeoppdrag
- Masking: Ingen (Open Label)
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Digital impression of the mandibular edentulous arch
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech.
Co., Ltd.
Hangzhou, China).
Both impressions will be compared to each other in terms of trueness.
|
Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech.
Co., Ltd.
Hangzhou, China).
Both impressions will be compared to each other in terms of trueness.
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
trueness assessment of impression techniques for mandibular edentulous arches
Tidsramme: 3 months
|
Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech.
Co., Ltd.
Hangzhou, China).
Both impressions will be compared to each other in terms of trueness in relation to desktop scanner.
Root mean square of trueness in m.m will be reported.
|
3 months
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- OOC-8-25-6
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .