Ion-selective electrode and anion gap range: What should the anion gap be?

Seyed-Ali Sadjadi, Rendell Manalo, Navin Jaipaul, James McMillan, Seyed-Ali Sadjadi, Rendell Manalo, Navin Jaipaul, James McMillan

Abstract

Background: Using flame photometry technique in the 1970s, the normal value of anion gap (AG) was determined to be 12 ± 4 meq/L. However, with introduction of the autoanalyzers using an ion-selective electrode (ISE), the anion gap value has fallen to lower levels.

Methods: A retrospective study of US veterans from a single medical center was performed to determine the value of the anion gap in subjects with normal renal function and normal serum albumin and in patients with lactic acidosis and end-stage renal disease on dialysis.

Results: In 409 patients with an estimated glomerular filtration rate ≥60 mL/min/1.73 m(2) body surface area and serum albumin ≥4 g/dL, the mean AG was 7.2 ± 2 (range 3-11) meq/L. In 299 patients with lactic acidosis (lactate level ≥4 meq/L) and 68 patients with endstage renal disease on dialysis, the mean AG was 12.5 meq/L and 12.4 meq/L, respectively. A value <2 meq/L should be considered a low anion gap and a possible clue to drug intoxication and paraproteinemic disorders.

Conclusion: With the advent of ISE for measurement of analytes, the value of the anion gap has fallen. Physicians need to be aware of the normal AG value in their respective institutions, and laboratories need to have an established value for AG based on the type of instrument they are using.

Keywords: ESRD; acidosis; electrolytes.

References

    1. Kraut J, Medias N. Serum anion gap: its uses and limitations in clinical medicine. Clin J Am Soc Nephrol. 2007;2:162–174.
    1. Van Hoeven KH, Joseph RE, Gaughan WJ, et al. The anion gap and routine serum protein measurements in monoclonal gammopathies. Clin J Am Soc Nephrol. 2011;6:2814–2821.
    1. Vasuyattakul S, Lertpattanasuwan N, Vareesangthi K, et al. A negative anion gap as clue to diagnosis of bromide intoxication. Nephron. 1995;69:311–313.
    1. Gabow PA. Disorders associated with an altered anion gap. Kidney Int. 1983;27:472–485.
    1. Fenves AZ, Kirkpatrick HM, Patel VV, Sweetman L, Emmett M. Increased anion gap metabolic acidosis as a result of 5-oxoproline (pyroglutamic acid): a role for acetaminophen. Clin J Am Soc Nephrol. 2006;1:441–447.
    1. Wittle DL, Rodgers JL, Barrett DA. The anion gap: its use in quality control. Clin Chem. 1976;22:643–648.
    1. Winter SD, Pearson JR, Gabow PA, Schultz AL, Lepoff RB. The fall of serum anion gap. Arch Intern Med. 1990;150:311–313.
    1. Sadjadi SA. A new range for anion gap. Ann Intern Med. 1995;123:807.
    1. Lolekha PH, Vanavanan S, Lolekha S. Update on value of anion gap in clinical diagnosis and laboratory evaluation. Clin Chim Acta. 2001;307:133–136.
    1. Hassan H, Joh JH, Bacon BR, Bastani B. Evaluation of serum anion gap in patients with liver cirrhosis of diverse etiologies. Mt Sinai J Med. 2004;71:281–284.
    1. Jurado RL, del Rio C, Nassar G, Navarettes J, Pimental IL. Low anion gap. South Med J. 1998;91:624–629.
    1. Kelleher SP, Raciti A, Arbeit LA. Reduced or absent serum AG as a marker of severe lithium carbonate intoxication. Arch Intern Med. 1986;146:1939–1940.
    1. Lee S, Kang KP, Kang SK. Clinical usefulness of the serum anion gap. Electrolyte Blood Press. 2006;4:44–46.
    1. Roberts WL, Johnson RD. Serum anion gap. Has the reference value really fallen. Arch Pathol Lab Med. 1997;121:568–572.
    1. Fortgens P, Pillay TS. Pseudohyponatremia revisited, a modern day pitfall. Arch Pathol Lab Med. 2011;135:516–519.
    1. Rastegar A. Clinical utility of Stewart’s method in diagnosis and management of acid base disorders. Clin J Am Soc Nephrol. 2009;4:1267–1274.
    1. Lloyd P. Strong ion calculator – a practical bedside application of modern quantitative acid-base physiology. Crit Care Resusc. 2004;6:285–294.
    1. Kaplan LJ, Frangos S. Clinical review: acid-base abnormalities in the intensive care unit. Crit Care. 2005;9:198–203.
    1. Di Iorio C, Rufolo L, Melillo EM, Granata A, Melillo G. The slide rule: a new method for the assessment of acid base equilibrium disorders. Minerva Anestesiol. 2007;73:339–342.
    1. Singh RN, Singh NC, Hutchison J, Moses GC. Lower anion gap increases sensitivity in predicting elevated lactate levels. Clin Intensive Care. 1994;5:221–224.
    1. Adams BD, Bonzani TA, Hunter CJ. The anion gap does not accurately screen for lactic acidosis in emergency department patients. Emerg Med. 2006;23:179–182.
    1. Abramowitz M, Hostetter T, Melamed ML. The serum anion gap is altered in early kidney disease and associates with mortality. Kidney Int. 2012;82:701–709.
    1. Siggard-Anderson O, Roth M, Strickland DAP. Workshop On pH and Blood Gases. Washington, DC; National Bureau of Standards; 1977. The buffer value of plasma, erythrocyte fluid and whole blood.
    1. Figge J, Jabor A, Kazda A, Fencl V. Anion gap and hypoalbuminemia. Crit Care Med. 1998;26:1807–1809.
    1. Nicholson JP, Wolmarans MR, Park GF. The role of albumin in critical illness. Br J Anaesth. 2000;85:599–610.
    1. Salem MM, Mujais SK. Gaps in the anion gap. Arch Intern Med. 1992;152:1625–1629.
    1. Carvounis C, Feinfeld DA. A simple estimate of the effect of serum albumin level on the anion gap. Am J Nephrol. 2000;20:369–372.
    1. Hatherill M, Waggie Z, Purves L, Reynolds L, Argent A. Correction of anion gap for albumin in order to detect occult tissue anions in shock. Arch Dis Child. 2002;87:526–529.
    1. Feldman M, Soni N, Dickson B. Influence of hypoalbuminemia or hyperalbuminemia on the serum anion gap. J Lab Clin Med. 2005;146:317–320.
    1. Dinh CH, Ng R, Grandinetti A, Joffe A, Chow DC. Correcting the anion gap for hypoalbuminemia does not improve detection of hyperlactatemia. Emerg Med J. 2006;23:627–629.
    1. Paulson WD. Effect of acute pH change on serum anion gap. J Am Soc Nephrol. 1996;7:357–363.
    1. Lolekha PH, Vanavanan S, Teerakanjana N, Chaichanajaremkul U. Reference ranges of electrolytes and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra. Clin Chem Acta. 2001;307:87–93.

Source: PubMed

3
Abonner