Comparison of in-hospital outcomes and readmissions for valve-in-valve transcatheter aortic valve replacement vs. reoperative surgical aortic valve replacement: a contemporary assessment of real-world outcomes

Sameer A Hirji, Edward D Percy, Cheryl K Zogg, Alexandra Malarczyk, Morgan T Harloff, Farhang Yazdchi, Tsuyoshi Kaneko, Sameer A Hirji, Edward D Percy, Cheryl K Zogg, Alexandra Malarczyk, Morgan T Harloff, Farhang Yazdchi, Tsuyoshi Kaneko

Abstract

Aims: We sought to perform a head-to-head comparison of contemporary 30-day outcomes and readmissions between valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) patients and a matched cohort of high-risk reoperative surgical aortic valve replacement (re-SAVR) patients using a large, multicentre, national database.

Methods and results: We utilized the nationally weighted 2012-16 National Readmission Database claims to identify all US adult patients with degenerated bioprosthetic aortic valves who underwent either VIV-TAVR (n = 3443) or isolated re-SAVR (n = 3372). Thirty-day outcomes were compared using multivariate analysis and propensity score matching (1:1). Unadjusted, VIV-TAVR patients had significantly lower 30-day mortality (2.7% vs. 5.0%), 30-day morbidity (66.4% vs. 79%), and rates of major bleeding (35.8% vs. 50%). On multivariable analysis, re-SAVR was a significant risk factor for both 30-day mortality [adjusted odds ratio (aOR) of VIV-SAVR (vs. re-SAVR) 0.48, 95% confidence interval (CI) 0.28-0.81] and 30-day morbidity [aOR for VIV-TAVR (vs. re-SAVR) 0.54, 95% CI 0.43-0.68]. After matching (n = 2181 matched pairs), VIV-TAVR was associated with lower odds of 30-day mortality (OR 0.41, 95% CI 0.23-0.74), 30-day morbidity (OR 0.53, 95% CI 0.43-0.72), and major bleeding (OR 0.66, 95% CI 0.51-0.85). Valve-in-valve TAVR was also associated with shorter length of stay (median savings of 2 days, 95% CI 1.3-2.7) and higher odds of routine home discharges (OR 2.11, 95% CI 1.61-2.78) compared to re-SAVR.

Conclusion: In this large, nationwide study of matched high-risk patients with degenerated bioprosthetic aortic valves, VIV-TAVR appears to confer an advantage over re-SAVR in terms of 30-day mortality, morbidity, and bleeding complications. Further studies are warranted to benchmark in low- and intermediate-risk patients and to adequately assess longer-term efficacy.

Keywords: Failed bioprostheses; Reoperative surgical aortic valve replacement; Valve-in-valve TAVR.

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.

Figures

Figure 1
Figure 1
Study flow diagram.
Figure 2
Figure 2
Forest plot demonstrating the independent predictors of 30-day morbidity following re-surgical aortic valve replacement and valve-in-valve transcatheter aortic valve replacement.
Take home figure
Take home figure
Visual Abstract summarizing key findings of this study.
https://www.ncbi.nlm.nih.gov/pmc/articles/instance/7395321/bin/eurheartj_41_29_2747_f3.jpg

Source: PubMed

3
Abonner