The Effect of Wearing Masks on End-tidal Carbon Dioxide and Pulse Oximetry
End-tidal Carbon Dioxide Measurements in Adults and Children Wearing Surgical Masks
An Interventional Study is planned with the primary purpose of screening for changes in end-tidal carbon dioxide (ETCO2), inspired carbon dioxide (ICO2), and other vital signs that may develop after donning a disposable surgical mask.
Measurements will be taken and recorded during a 5-minute control period without a mask, recording non-invasive ETCO2 and ICO2 levels by way of a nasal cannula (NC), oxygen saturation (SpO2), breaths per minute (RR), and heart rate (HR) via anesthesia equipment. This will be followed by a 15-minute intervention of wearing a disposable surgical mask and repeating measurements of ETCO2, ICO2, SpO2, RR, and HR, recorded each minute.
Data will be collected from adults and children as young as 2 years of age. Age groups will include children aged 2-14 and adults aged 18 to 80, as described in the details of the research protocol. Parents and their children are invited to participate together.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Missouri
-
Springfield, Missouri, Vereinigte Staaten, 65897-0027
- Missouri State University
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Good health
- Aged 2 - 14 years (inclusive) or 18 - 80 years (inclusive)
Exclusion Criteria:
- Significant cardiopulmonary diseases
- Intolerance to wearing nasal canula
- Intolerance to wearing a surgical mask
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Screening
- Zuteilung: N / A
- Interventionsmodell: Sequenzielle Zuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
---|---|
Experimental: Effects of donning a disposable surgical mask
Participants will be observed and monitored without wearing a mask for a 5-minute control period. Measurements will include End Tidal CO2, Inspired CO2, Pulse Oximetry, Respiratory Rate, and Heart Rate each minute without a mask x 5 minutes. After 5 minutes, all study subjects will don the same model of disposable surgical mask. The same measurements will be taken, including End Tidal CO2, Inspired CO2, Pulse Oximetry, Respiratory Rate, and Heart Rate each minute with a mask x 15 minutes. |
Physiologic vital signs will be monitored every minute for 5 minutes without a mask, followed by every minute for 15 minutes with a surgical mask.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
---|---|---|
Potential Change in End Tidal CO2 level
Zeitfenster: End tidal CO2 levels after 5 minutes without a mask will be compared to End Tidal CO2 levels after 15 minutes wearing a disposable surgical mask
|
measurement of End Tidal CO2 by way of nasal cannula
|
End tidal CO2 levels after 5 minutes without a mask will be compared to End Tidal CO2 levels after 15 minutes wearing a disposable surgical mask
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
---|---|---|
Potential change in Inspired CO2 level
Zeitfenster: Inspired CO2 levels after 5 minutes without a mask will be compared to Inspired CO2 levels after 15 minutes wearing a disposable surgical mask
|
measurement of inspired CO2 by way of nasal cannula
|
Inspired CO2 levels after 5 minutes without a mask will be compared to Inspired CO2 levels after 15 minutes wearing a disposable surgical mask
|
Potential change in oxygen saturation
Zeitfenster: Oxygen saturation levels after 5 minutes without a mask will be compared to oxygen saturation levels after 15 minutes wearing a disposable surgical mask
|
measurement of oxygen saturation by way of noninvasive pulse oximetry
|
Oxygen saturation levels after 5 minutes without a mask will be compared to oxygen saturation levels after 15 minutes wearing a disposable surgical mask
|
Potential change in respiratory rate measured in breaths per minute
Zeitfenster: Respiratory rate after 5 minutes without a mask will be compared to respiratory rate after 15 minutes wearing a disposable surgical mask
|
measurement of breaths per minute
|
Respiratory rate after 5 minutes without a mask will be compared to respiratory rate after 15 minutes wearing a disposable surgical mask
|
Potential change in Heart Rate
Zeitfenster: Heart rate after 5 minutes without a mask will be compared to heart rate after 15 minutes wearing a disposable surgical mask
|
measurement of heart rate in beats per minute
|
Heart rate after 5 minutes without a mask will be compared to heart rate after 15 minutes wearing a disposable surgical mask
|
Mitarbeiter und Ermittler
Sponsor
Mitarbeiter
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- CT-2021-01
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Kohlendioxid
-
Hôpital Léon BérardAbgeschlossenN von 1 Studiendesign | Sprintleistung | Carbon Spike-Schuh | Kraft-GeschwindigkeitsprofilFrankreich
Klinische Studien zur wearing a disposable surgical mask
-
Cairo UniversityAbgeschlossen