- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT06871020
Parodontale Gesundheit und Patientenzufriedenheit von CAD/CAM-Faserverstärkten im Vergleich zu PFM-Anhängen in distalen Verlängerungs-RPDs: A RCT
Bewertung der parodontalen Gesundheit und Patientenzufriedenheit von CAD/CAM-Faserverstärkungsverbund gegen Porzellan, die an die extrakoronale Metallbefugnis in der mandibulären distalen Erweiterung abnehmbarer partieller Zahnprothoren fusioniert sind: Eine randomisierte klinische Studie
This randomized clinical trial aims to assess periodontal health and patient satisfaction in mandibular distal extension removable partial dentures using CAD/CAM fiber-reinforced composite versus porcelain-fused-to-metal extracoronal attachments. Twenty-four participants with bilateral mandibular Kennedy Class I, retaining only the canines and first premolars as the last standing abutments bilaterally, will be randomly assigned to two groups. Group I (n=12) will receive OT extracoronal attachments made from CAD/CAM fiber-reinforced composite, while Group II (n=12) will receive OT extracoronal attachments made from porcelain-fused-to-metal. All participants will then receive a metallic removable partial denture. The null hypothesis states that no significant differences will be observed in periodontal health and patient satisfaction between the two attachment types.
Studienübersicht
Status
Bedingungen
Detaillierte Beschreibung
Twenty four participants with bilateral maxillary Kennedy Class I, with the canines and first premolars as the last standing abutments, will be recruited based on strict inclusion criteria from the oral and maxillofacial prosthodontic outpatient clinic. The canines and first premolars (teeth 34,35,44,45) will be prepared to receive OT extracoronal attachments made from either CAD/CAM fiber-reinforced composite (Group I) or porcelain-fused-to-metal (Group II), according to group allocation. All participants will then receive a metallic removable partial denture. Periodontal health will be assessed through bleeding index, probing depth, and gingival recession at denture insertion and after six months and twelve months. Patient satisfaction will also be evaluated at the twelve-month follow-up.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Cairo, Ägypten, 12345
- Faculty of Dentistry Ain Shams University
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Mandibular partially edentulous bilateral distal extension Kennedy Class I with canines and first premolars as last abutments.
- The opposing maxillary arch will be dentate.
- Angle class I maxillomandibular skeletal relation.
- The distal extension ridge will be well-formed and covered by healthy and firm mucosa.
- As verified by periapical radiographs, Abutments have healthy periodontal ligaments and an appropriate crown/root ratio (CRR).
- Crown/root ratio of the premolar abutment teeth is not less than 1:1. 5.
- The vertical distance between the ridge tissue and the opposing teeth of the study cases is not less than 7 mm. 6.
- The buccolingual dimension of the abutment teeth is not less than 6 mm.
Exclusion Criteria:
- Patients with any systemic disease that could affect the rate of bone resorption, which was confirmed by obtaining a through medical history.
- Patients with parafunctional habits (bruxism and clenching).
- Patients with any septic foci or impacted teeth as proved by panoramic radiograph, as well as patients with tilted or rotated abutments or soft tissue undercuts in areas that will be involved in the RDP design.
- Patients with any TMJ problems.
- Patients with any neuromuscular diseases.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Doppelt
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: OT Extracoronal attachment made from CAD-CAM fiber-reinforced composite resin.
The patient will receive a removable partial denture retained by bilateral OT extracoronal attachments made from CAD/CAM fiber-reinforced composite resin. These attachments will be fabricated on the prepared first premolars and canines on each side (34,35,44,45 teeth). |
Bilateral OT extracoronal attachments will be milled from fiber-reinforced composite resin after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments. |
|
Aktiver Komparator: OT Extracoronal attachment made from porcelain-fused-to-metal
The patient will receive a removable partial denture retained by bilateral OT Extracoronal attachment made from porcelain-fused-to-metal . These attachments will be fabricated on the prepared first premolars and canines on each side (34,35,44,45 teeth).. |
Bilateral OT attachments manufactured from porcelain fused to metal by conventional technique after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Evaluation of Bleeding index
Zeitfenster: At denture insertion ( baseline 0) , six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
The bleeding Index will be evaluated at denture insertion, after six months, and 12 months after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments it will be evaluated according to Lang et al. at four sites per tooth (buccal, lingual, mesiobuccal, and distobuccal) using a UNC-15 probe (Oroax, Woodbridge, Virginia, USA). Bleeding within 30 seconds of gentle probing will be recorded, and the BOP percentage will be calculated as the number of bleeding sites divided by the total number of sites examined, multiplied by 100. |
At denture insertion ( baseline 0) , six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
|
Evaluation of Probing Pocket Depth (PPD)
Zeitfenster: At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Evaluation of Probing Pocket Depth (PPD)will be evaluated atdenture insertion, after six months, and 12 months after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments . it will be evaluated measured at six sites per tooth using a graduated periodontal probe will be positioned parallel to the tooth's long axis . The distance from the gingival margin to the base of the sulcus or periodontal pocket will be recorded, and mean values will be calculated for each abutment. |
At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
|
Evaluation Gingival Index (GI)
Zeitfenster: At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Evaluation of Gingival index: Evaluated using Löe and Silness (1963), scoring gingival inflammation from 0 (healthy) to 3 (severe inflammation with spontaneous bleeding). |
At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Evaluation of Patient Satisfaction
Zeitfenster: After tweleve months (180 days) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Patient satisfaction will be evaluated using the McGill Denture Satisfaction Questionnaire and a visual analog scale (VAS). Satisfaction will be measured across multiple aspects, including ease of cleaning, speech ability, comfort, esthetics, stability, mastication of various foods, masticatory efficiency, oral condition, and overall satisfaction. Patients will rate each item on a 0-100 scale, where 0 represents complete dissatisfaction and 100 indicates total satisfaction. |
After tweleve months (180 days) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Omnia M. Refai, PHD, Ain Shams Univeristy
- Studienleiter: Noha Helmy Hassan Nawar, PHD, Ain Shams Univeristy
- Hauptermittler: Heba A. Salama, PHD, Misr International University
- Hauptermittler: Abdel Rahman Maged, PHD, Misr International University
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- FDASU-RecIR122439
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .