Salute parodontale e soddisfazione del paziente di attaccamenti CAD/CAM Fiber Forced vs. PFM in RPDS di estensione distale: un RCT
Valutazione della salute parodontale e della soddisfazione del paziente del composito composito a fibra CAD/CAM rispetto alla porcellana fusa nell'attaccamento extracoronale metallico nell'estensione distale mandibolare Denta parziali rimovibili: una sperimentazione clinica randomizzata
This randomized clinical trial aims to assess periodontal health and patient satisfaction in mandibular distal extension removable partial dentures using CAD/CAM fiber-reinforced composite versus porcelain-fused-to-metal extracoronal attachments. Twenty-four participants with bilateral mandibular Kennedy Class I, retaining only the canines and first premolars as the last standing abutments bilaterally, will be randomly assigned to two groups. Group I (n=12) will receive OT extracoronal attachments made from CAD/CAM fiber-reinforced composite, while Group II (n=12) will receive OT extracoronal attachments made from porcelain-fused-to-metal. All participants will then receive a metallic removable partial denture. The null hypothesis states that no significant differences will be observed in periodontal health and patient satisfaction between the two attachment types.
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
Twenty four participants with bilateral maxillary Kennedy Class I, with the canines and first premolars as the last standing abutments, will be recruited based on strict inclusion criteria from the oral and maxillofacial prosthodontic outpatient clinic. The canines and first premolars (teeth 34,35,44,45) will be prepared to receive OT extracoronal attachments made from either CAD/CAM fiber-reinforced composite (Group I) or porcelain-fused-to-metal (Group II), according to group allocation. All participants will then receive a metallic removable partial denture. Periodontal health will be assessed through bleeding index, probing depth, and gingival recession at denture insertion and after six months and twelve months. Patient satisfaction will also be evaluated at the twelve-month follow-up.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Cairo, Egitto, 12345
- Faculty of Dentistry Ain Shams University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Mandibular partially edentulous bilateral distal extension Kennedy Class I with canines and first premolars as last abutments.
- The opposing maxillary arch will be dentate.
- Angle class I maxillomandibular skeletal relation.
- The distal extension ridge will be well-formed and covered by healthy and firm mucosa.
- As verified by periapical radiographs, Abutments have healthy periodontal ligaments and an appropriate crown/root ratio (CRR).
- Crown/root ratio of the premolar abutment teeth is not less than 1:1. 5.
- The vertical distance between the ridge tissue and the opposing teeth of the study cases is not less than 7 mm. 6.
- The buccolingual dimension of the abutment teeth is not less than 6 mm.
Exclusion Criteria:
- Patients with any systemic disease that could affect the rate of bone resorption, which was confirmed by obtaining a through medical history.
- Patients with parafunctional habits (bruxism and clenching).
- Patients with any septic foci or impacted teeth as proved by panoramic radiograph, as well as patients with tilted or rotated abutments or soft tissue undercuts in areas that will be involved in the RDP design.
- Patients with any TMJ problems.
- Patients with any neuromuscular diseases.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: OT Extracoronal attachment made from CAD-CAM fiber-reinforced composite resin.
The patient will receive a removable partial denture retained by bilateral OT extracoronal attachments made from CAD/CAM fiber-reinforced composite resin. These attachments will be fabricated on the prepared first premolars and canines on each side (34,35,44,45 teeth). |
Bilateral OT extracoronal attachments will be milled from fiber-reinforced composite resin after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments. |
|
Comparatore attivo: OT Extracoronal attachment made from porcelain-fused-to-metal
The patient will receive a removable partial denture retained by bilateral OT Extracoronal attachment made from porcelain-fused-to-metal . These attachments will be fabricated on the prepared first premolars and canines on each side (34,35,44,45 teeth).. |
Bilateral OT attachments manufactured from porcelain fused to metal by conventional technique after obtaining impressions of the prepared abutments. This will be followed by an overall impression of fabricating a Co-Cr removable partial denture to be retained in the attachments. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Evaluation of Bleeding index
Lasso di tempo: At denture insertion ( baseline 0) , six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
The bleeding Index will be evaluated at denture insertion, after six months, and 12 months after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments it will be evaluated according to Lang et al. at four sites per tooth (buccal, lingual, mesiobuccal, and distobuccal) using a UNC-15 probe (Oroax, Woodbridge, Virginia, USA). Bleeding within 30 seconds of gentle probing will be recorded, and the BOP percentage will be calculated as the number of bleeding sites divided by the total number of sites examined, multiplied by 100. |
At denture insertion ( baseline 0) , six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
|
Evaluation of Probing Pocket Depth (PPD)
Lasso di tempo: At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Evaluation of Probing Pocket Depth (PPD)will be evaluated atdenture insertion, after six months, and 12 months after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments . it will be evaluated measured at six sites per tooth using a graduated periodontal probe will be positioned parallel to the tooth's long axis . The distance from the gingival margin to the base of the sulcus or periodontal pocket will be recorded, and mean values will be calculated for each abutment. |
At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
|
Evaluation Gingival Index (GI)
Lasso di tempo: At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Evaluation of Gingival index: Evaluated using Löe and Silness (1963), scoring gingival inflammation from 0 (healthy) to 3 (severe inflammation with spontaneous bleeding). |
At denture insertion ( baseline 0), six months (T1) , and 12 months (T2) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Evaluation of Patient Satisfaction
Lasso di tempo: After tweleve months (180 days) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Patient satisfaction will be evaluated using the McGill Denture Satisfaction Questionnaire and a visual analog scale (VAS). Satisfaction will be measured across multiple aspects, including ease of cleaning, speech ability, comfort, esthetics, stability, mastication of various foods, masticatory efficiency, oral condition, and overall satisfaction. Patients will rate each item on a 0-100 scale, where 0 represents complete dissatisfaction and 100 indicates total satisfaction. |
After tweleve months (180 days) after delivery of mandibular removable partial denture retained on double OT Extracoronal attachments
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Omnia M. Refai, PHD, Ain Shams Univeristy
- Direttore dello studio: Noha Helmy Hassan Nawar, PHD, Ain Shams Univeristy
- Investigatore principale: Heba A. Salama, PHD, Misr International University
- Investigatore principale: Abdel Rahman Maged, PHD, Misr International University
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- FDASU-RecIR122439
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .