- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07620379
Evaluation of Materials for the Distribution of Pressure in the Treatment of Neuroischemic Ulcers
The hypothesis of this study is based on the premise that pressure-distributing materials with superior biomechanical and tissue response properties will be capable of improving the healing rate of neuropathic ulcers.
The overarching objective of the present project is to assess the influence of the nature and method of application of the materials under study on tissue response, the reduction of pressure on the sole of the foot, and the healing of neuropathic ulcers in patients with diabetes mellitus.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
The study is divided into two distinct phases:
The following analysis is concerned with the characteristics of materials that are employed for the purpose of the distribution of pressure. This will entail the meticulous analysis of the response exhibited by the materials, with the objective of ascertaining their true biomechanical behaviour in volunteers devoid of active ulcers.
The materials selected in the first part will be applied for the treatment of revascularised neuroischaemic ulcers. This will determine which of the materials is the most suitable for treating the lesion.
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienkontakt
- Name: IVAN JULIAN ROCHINA, PhD
- Telefonnummer: +34 639687251
- E-Mail: ivan.julian@uv.es
Studienorte
-
-
Valencia
-
Valencia, Valencia, Spanien
- Rekrutierung
- Hospital Universitario y Politécnico La Fe
-
Kontakt:
- IVAN JULIAN ROCHINA
- Telefonnummer: +34639687251
- E-Mail: ivan.julian@uv.es
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Aged between 55 and 75.
- Diagnosis of diabetes mellitus.
- Patients with an ankle-brachial index of >0.8 and <1.2.
- Signature of the informed consent form
Exclusion Criteria:
- Leg or foot injuries or ulcers that cause pain and prevent normal movement in both lower limbs.
- Foot trauma within the last month.
- Inability to adhere to the full schedule of measurements required by the study.
- Participants who do not sign the informed consent form.
- Known contact dermatitis to any of the study materials
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Verhütung
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: felt padding
The 5 mm and 10 mm felt pads are applied for 4 days.
|
The 5 mm felt pad is applied for 4 days and then removed.
After allowing the skin at least 48 hours to recover, the 10 mm felt pad is applied, also for 4 days.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Near-infrared perfusion index (NIR perfusion)
Zeitfenster: Baseline and 4 days
|
Hyperspectral imaging was performed using the TIVITA® 2.0 camera (Diaspective Vision GmbH, Germany).
This non-contact, non-invasive device captures images across multiple wavelengths within the visible and near-infrared spectrum (500-1000 nm), enabling assessment of microcirculatory parameters up to a tissue depth of approximately 8 mm.
The device provides an image resolution of 640 × 480 pixels, with an acquisition time of 6.4 seconds.
Images were analyzed using TIVITA® Suite software by selecting a circular region of interest adjusted to the metatarsal head and offloading area under study.
|
Baseline and 4 days
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Thermography
Zeitfenster: Baseline and 4 days
|
The images will be captured using the FLIR C8 thermal imaging camera.
The camera in question features a true thermal resolution of 320 × 240 pixels (76,800 measurement points) and MSX® technology, which combines visual and thermal details into a single image, thereby facilitating the detection of anatomical abnormalities.
Thermographic variables of interest included differences in absolute temperature values (maximum and mean temperature) within the region of interest corresponding to the offloading area.
|
Baseline and 4 days
|
|
Peak pressure (Pmax)
Zeitfenster: Baseline and 4 days
|
Peak pressure (Pmax) measured at the metatarsal head corresponding to the highest dynamic pressure. Plantar pressures were assessed using the EPS+R platform (Loran Engineering®, Bologna, Italy). The platform measures 50 × 70 × 4 mm, weighs 7 kg, and incorporates 2304 resistive sensors measuring 9 × 9 mm each. The pressure range is 50-350 kPa, with a maximum acquisition frequency of 100 Hz. Biomech® Studio 2019 software (LetSense Srl, Loran Engineering®) was used for data analysis. |
Baseline and 4 days
|
|
Tissue oxygen saturation (StO₂)
Zeitfenster: Baseline and 4 days
|
Hyperspectral imaging was performed using the TIVITA® 2.0 camera (Diaspective Vision GmbH, Germany).
This non-contact, non-invasive device captures images across multiple wavelengths within the visible and near-infrared spectrum (500-1000 nm), enabling assessment of microcirculatory parameters up to a tissue depth of approximately 8 mm.
The device provides an image resolution of 640 × 480 pixels, with an acquisition time of 6.4 seconds.
Images were analyzed using TIVITA® Suite software by selecting a circular region of interest adjusted to the metatarsal head and offloading area under study.
|
Baseline and 4 days
|
|
Tissue hemoglobin index (THI)
Zeitfenster: Baseline and 4 days
|
Hyperspectral imaging was performed using the TIVITA® 2.0 camera (Diaspective Vision GmbH, Germany).
This non-contact, non-invasive device captures images across multiple wavelengths within the visible and near-infrared spectrum (500-1000 nm), enabling assessment of microcirculatory parameters up to a tissue depth of approximately 8 mm.
The device provides an image resolution of 640 × 480 pixels, with an acquisition time of 6.4 seconds.
Images were analyzed using TIVITA® Suite software by selecting a circular region of interest adjusted to the metatarsal head and offloading area under study.
|
Baseline and 4 days
|
|
Tissue wáter index (TWI)
Zeitfenster: Baseline and 4 days
|
Hyperspectral imaging was performed using the TIVITA® 2.0 camera (Diaspective Vision GmbH, Germany).
This non-contact, non-invasive device captures images across multiple wavelengths within the visible and near-infrared spectrum (500-1000 nm), enabling assessment of microcirculatory parameters up to a tissue depth of approximately 8 mm.
The device provides an image resolution of 640 × 480 pixels, with an acquisition time of 6.4 seconds.
Images were analyzed using TIVITA® Suite software by selecting a circular region of interest adjusted to the metatarsal head and offloading area under study.
|
Baseline and 4 days
|
|
Tissue lipid index (TLI)
Zeitfenster: Baseline and 4 days
|
Hyperspectral imaging was performed using the TIVITA® 2.0 camera (Diaspective Vision GmbH, Germany).
This non-contact, non-invasive device captures images across multiple wavelengths within the visible and near-infrared spectrum (500-1000 nm), enabling assessment of microcirculatory parameters up to a tissue depth of approximately 8 mm.
The device provides an image resolution of 640 × 480 pixels, with an acquisition time of 6.4 seconds.
Images were analyzed using TIVITA® Suite software by selecting a circular region of interest adjusted to the metatarsal head and offloading area under study.
|
Baseline and 4 days
|
|
Mean pressure (Pmean)
Zeitfenster: Baseline and 4 days
|
Mean pressure (Pmean) measured at the metatarsal head corresponding to the highest dynamic pressure. Plantar pressures were assessed using the EPS+R platform (Loran Engineering®, Bologna, Italy). The platform measures 50 × 70 × 4 mm, weighs 7 kg, and incorporates 2304 resistive sensors measuring 9 × 9 mm each. The pressure range is 50-350 kPa, with a maximum acquisition frequency of 100 Hz. Biomech® Studio 2019 software (LetSense Srl, Loran Engineering®) was used for data analysis. |
Baseline and 4 days
|
Mitarbeiter und Ermittler
Sponsor
Mitarbeiter
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 2020-672-1
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Diabetische Komplikationen
-
Steno Diabetes Center CopenhagenMosaiques Diagnostics GmbHAnmeldung auf EinladungAlbuminurie | Geben Sie 2 DM ein | Typ 2 DM /Diabetic NephropathyDänemark