Inferior Vena Cava Versus Subclavian Vein Collapsibility for Predicting Fluid Responsiveness in Trauma Hemorrhagic Shock

9. September 2026 aktualisiert von: Basant Saody Hashem, Assiut University

Comparison of Inferior Vena Cava Versus Subclavian Vein Collapsibility Indices for Prediction of Fluid Responsiveness in Adult Trauma Patients Presenting With Hemorrhagic Shock: A Prospective Comparative Cohort Study

Hemorrhagic shock from severe bleeding is a leading cause of preventable death in trauma patients. Intravenous (IV) fluid resuscitation is essential for stabilizing blood pressure and organ perfusion, but administering too much or too little fluid can cause severe complications. Only about half of hemodynamically unstable patients show an increase in cardiac output after receiving fluids. Emergency physicians often use bedside ultrasound to measure respiratory changes in the inferior vena cava (IVC), known as the IVC collapsibility index (IVC-CI), to predict whether a patient will benefit from fluids. However, obtaining clear IVC views can be difficult or impossible in trauma patients due to abdominal pain, obesity, or abdominal injuries. Evaluating the subclavian vein (SCV) under the collarbone provides a potential alternative window.

The main purpose of this study is to compare the diagnostic accuracy of the subclavian vein collapsibility index (SCV-CI) against the inferior vena cava collapsibility index (IVC-CI) for predicting fluid responsiveness in adult trauma patients presenting with hemorrhagic shock.

Eligible adult trauma patients with hemorrhagic shock will undergo rapid bedside point-of-care ultrasound upon presentation to the emergency department. Physicians will measure respiratory diameter variations in both the subclavian vein and inferior vena cava. Patients will then receive a standardized fluid challenge of 10 mL/kg intravenous balanced crystalloid solution over 10 to 15 minutes as part of resuscitation. Fluid responsiveness will be assessed by measuring changes in blood flow through the neck using carotid artery Doppler ultrasound before and 5 to 10 minutes after the fluid challenge. The study will determine whether subclavian vein ultrasound offers comparable diagnostic performance and greater feasibility compared to inferior vena cava ultrasound in emergency trauma resuscitation.

Studienübersicht

Status

Noch keine Rekrutierung

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

120

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

N/A

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Adult trauma patients aged 18 years or older presenting with blunt or penetrating trauma and clinical evidence of hemorrhagic shock (systolic blood pressure < 90 mmHg, mean arterial pressure < 65 mmHg, or clinical signs of tissue hypoperfusion) to the Emergency Department of Assiut University Trauma and Emergency Hospital within 6 hours of injury.

Beschreibung

Inclusion Criteria:

  • Adult patients aged 18 years or older.
  • Presentation with blunt or penetrating trauma.
  • Clinical evidence of hemorrhagic shock, defined by hypotension (systolic blood pressure < 90 mmHg or mean arterial pressure < 65 mmHg), tachycardia, or other clinical signs of tissue hypoperfusion requiring fluid resuscitation.
  • Spontaneously breathing patients.
  • Presentation to the Emergency Department within 6 hours of injury.
  • Feasibility of bedside point-of-care ultrasound examination prior to the initiation of definitive resuscitation.

Exclusion Criteria:

  • Age younger than 18 years.
  • Pregnancy.
  • Requirement for immediate endotracheal intubation and mechanical ventilation prior to ultrasound assessment.
  • Obstructive shock due to cardiac tamponade, tension pneumothorax, or other known causes.
  • Known severe heart failure with left ventricular ejection fraction (LVEF) < 40%.
  • Significant tricuspid regurgitation or known pulmonary hypertension that may affect systemic venous measurements.
  • Major neck or clavicular trauma preventing adequate subclavian vein ultrasound acquisition.
  • Extensive abdominal trauma, morbid obesity, or other conditions precluding adequate inferior vena cava (IVC) acoustic visualization.
  • Transfer from another facility after receiving large-volume fluid resuscitation (> 1 L of crystalloids or blood products prior to assessment).
  • Inability or refusal to provide informed consent by the patient or their legally authorized representative.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Adult Trauma Patients with Hemorrhagic Shock
Spontaneously breathing adult trauma patients (aged ≥ 18 years) presenting to the Emergency Department within 6 hours of blunt or penetrating injury with clinical evidence of hemorrhagic shock (SBP < 90 mmHg or MAP < 65 mmHg, tachycardia, or tissue hypoperfusion). All enrolled participants undergo baseline point-of-care ultrasound examination to measure both the inferior vena cava collapsibility index (IVC-CI) and subclavian vein collapsibility index (SCV-CI), in addition to carotid artery velocity time integral (Carotid VTI). Following baseline ultrasound, participants receive a standardized fluid challenge of 10 mL/kg intravenous balanced crystalloid over 10-15 minutes. Carotid VTI is remeasured within 5-10 minutes post-infusion to evaluate fluid responsiveness (defined as a Carotid VTI increase ≥ 15%).

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Area Under the Receiver Operating Characteristic Curve (AUC) of Subclavian Vein Collapsibility Index (SCV-CI)
Zeitfenster: 10 minutes post-fluid challenge
The area under the receiver operating characteristic curve (AUC-ROC) will be calculated to determine the diagnostic accuracy of baseline SCV-CI for predicting fluid responsiveness. Fluid responsiveness is defined as an increase of ≥ 15% in carotid artery velocity time integral (Carotid VTI) following a 10 mL/kg crystalloid bolus. AUC values range from 0.5 (no discriminative ability) to 1.0 (perfect diagnostic accuracy).
10 minutes post-fluid challenge

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Oktober 2026

Primärer Abschluss (Geschätzt)

1. Oktober 2027

Studienabschluss (Geschätzt)

1. November 2027

Studienanmeldedaten

Zuerst eingereicht

9. September 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

9. September 2026

Zuerst gepostet (Tatsächlich)

14. September 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

14. September 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

9. September 2026

Zuletzt verifiziert

1. September 2026

Mehr Informationen

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren