- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01294839
Right Ventricular Outflow Tract Study (RVOTCARE)
Right Ventricular Outflow Tract Septal Pacing for Cardiac Dysfunction Prevention Evaluation
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Ventricular pacing is unavoidable in many patients because of unreliable or absent AV conduction, or permanent AF. In recognition of this need, interest has focused on alternative site(s) ventricular pacing to maximize pumping function. These sites include the RV septum, His bundle, various LV sites, and combination of LV and RV (biventricular [BiV]). The RV outflow tract septum (RVOTs) seems to be the most promising site within the RV.
However, small enrollment and inconsistent experimental methods hinder the interpretation of these studies. Locations of alternative pacing sites were not clearly specified, were largely topographic, and lacked consistent anatomic designation. And what is more, there was no prospective, double-blind randomized, multi-center clinical trial which is design to test whether RVOTs pacing is superior to right ventricular apical pacing in preserving left ventricular systolic function and avoiding adverse left ventricular remodeling in patients with a normal left ventricular ejection fraction, ventricular synchrony and standard indications for pacing (sinus node dysfunction) in China. There was also no prospective, double-blind randomized, multi-center clinical trial which is design to test whether RVOTs pacing is not inferior to AAIR pacing in preserving left ventricular systolic function and avoiding adverse left ventricular remodeling in patients with a normal left ventricular ejection fraction, ventricular synchrony and sinus node dysfunction in the world.
So SJM China will sponsor a prospective, randomized, double blinded, multi-center, controlled study to evaluate the clinical impact at 18 months after DDD implantation of alternative pacing site (RVOTs and RVA) and the different conduction path (RVOTs and AV node) on cardiac dysfunction prevention.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Guangdong
-
Guang Zhou, Guangdong, Porcelana, 510030
- Guang Dong General Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Patients with only sinus-node dysfunction and meet pacing indication
- Patients with LVEF≥60% and with ventricular synchrony.
- Patients signed the written informed consent for the study
- Patients can endure the required follow up
Exclusion Criteria:
- Patients with atrial fibrillation
- Patients with atrial-ventricular block
- Patients with LBBB
- Patients with significant valvular disease
- Patients with severe hematopathy or severe renal inadequacy
- Patients with life expectancy < 1.5 year
- Patients who are in the period of pregnant or lactation
- Patients who are younger than 18 years old
- Patients who are ongoing other devices or agents study
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Triple
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: RVOTs
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in RVOTs arm, the RV lead of this group patients will be implanted in right ventricular outflow tract septum,the accumulated ventricular pacing percentage should be over 80% by adjusting AV delays.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
|
Experimental: AAI
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in AAI arm, the RV lead of this group patients will be implanted in right ventricular apex.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
|
Comparador activo: RVA
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in RVA arm, the RV lead of this group patients will be implanted in right ventricular apex, the accumulated ventricular pacing percentage should be over 80% by adjusting AV delays.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Left ventricular ejection fraction (LVEF)
Periodo de tiempo: 18 months
|
To demonstrate:
|
18 months
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
left ventricular end-systolic volume (LVESV)
Periodo de tiempo: 18 months
|
To demonstrate:
|
18 months
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- CR-10-016-AP-LV
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .