- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT01294839
Right Ventricular Outflow Tract Study (RVOTCARE)
Right Ventricular Outflow Tract Septal Pacing for Cardiac Dysfunction Prevention Evaluation
Обзор исследования
Статус
Условия
Вмешательство/лечение
Подробное описание
Ventricular pacing is unavoidable in many patients because of unreliable or absent AV conduction, or permanent AF. In recognition of this need, interest has focused on alternative site(s) ventricular pacing to maximize pumping function. These sites include the RV septum, His bundle, various LV sites, and combination of LV and RV (biventricular [BiV]). The RV outflow tract septum (RVOTs) seems to be the most promising site within the RV.
However, small enrollment and inconsistent experimental methods hinder the interpretation of these studies. Locations of alternative pacing sites were not clearly specified, were largely topographic, and lacked consistent anatomic designation. And what is more, there was no prospective, double-blind randomized, multi-center clinical trial which is design to test whether RVOTs pacing is superior to right ventricular apical pacing in preserving left ventricular systolic function and avoiding adverse left ventricular remodeling in patients with a normal left ventricular ejection fraction, ventricular synchrony and standard indications for pacing (sinus node dysfunction) in China. There was also no prospective, double-blind randomized, multi-center clinical trial which is design to test whether RVOTs pacing is not inferior to AAIR pacing in preserving left ventricular systolic function and avoiding adverse left ventricular remodeling in patients with a normal left ventricular ejection fraction, ventricular synchrony and sinus node dysfunction in the world.
So SJM China will sponsor a prospective, randomized, double blinded, multi-center, controlled study to evaluate the clinical impact at 18 months after DDD implantation of alternative pacing site (RVOTs and RVA) and the different conduction path (RVOTs and AV node) on cardiac dysfunction prevention.
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Guangdong
-
Guang Zhou, Guangdong, Китай, 510030
- Guang Dong General Hospital
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Patients with only sinus-node dysfunction and meet pacing indication
- Patients with LVEF≥60% and with ventricular synchrony.
- Patients signed the written informed consent for the study
- Patients can endure the required follow up
Exclusion Criteria:
- Patients with atrial fibrillation
- Patients with atrial-ventricular block
- Patients with LBBB
- Patients with significant valvular disease
- Patients with severe hematopathy or severe renal inadequacy
- Patients with life expectancy < 1.5 year
- Patients who are in the period of pregnant or lactation
- Patients who are younger than 18 years old
- Patients who are ongoing other devices or agents study
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Тройной
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: RVOTs
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in RVOTs arm, the RV lead of this group patients will be implanted in right ventricular outflow tract septum,the accumulated ventricular pacing percentage should be over 80% by adjusting AV delays.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
|
Экспериментальный: AAI
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in AAI arm, the RV lead of this group patients will be implanted in right ventricular apex.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
|
Активный компаратор: RVA
555 Patients will be randomized to three groups(RVOTs, RVA, AAI) in 1:1:1, 185 patients in RVA arm, the RV lead of this group patients will be implanted in right ventricular apex, the accumulated ventricular pacing percentage should be over 80% by adjusting AV delays.
|
RV leads in RVOTs group will be located in right ventricular outflow tract septum, RV leads in the other two group will be implanted in right ventricular apex, for the last RVOTs and RVA groups, the accumulated ventricular pacrouping percentage should be over 80% by adjusting AV delays.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Left ventricular ejection fraction (LVEF)
Временное ограничение: 18 months
|
To demonstrate:
|
18 months
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
left ventricular end-systolic volume (LVESV)
Временное ограничение: 18 months
|
To demonstrate:
|
18 months
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- CR-10-016-AP-LV
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .