Pressure-limited Ventilation Versus Volume-targeted Ventilation in Term Newborns
Randomised Controlled Trial Comparing Volume-targeted to Pressure-limited Ventilation in Infants Born at or Near Term
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Aims: There is increasing evidence that volume-targeted ventilation (VTV) holds benefits for preterm infants in comparison to pressure-limited ventilation. It is not known whether the same is true in the case of infants born at term. This study aims to compare pressure-limited to VTV in term-born infants.
Hypothesis: Volume-targeted will be associated with significantly earlier extubation compared to pressure-limited ventilation Primary outcome: Time to extubation. Methods: Ventilated infants 34 weeks or more gestational age at birth were recruited and randomly allocated to receive either pressure-limited or VTV. Adjustments to ventilator settings were made according to the trial protocol. Infants were deemed to have met failure criteria if they required HFOV or peak pressures of more than 30 cm of water. Analysis will be by intention-to-treat.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
London, Reino Unido, SE5 9RS
- King's College Hospital NHS Foundation Trust
-
London, Reino Unido, SE5 9RS
- Neonatal intensive care unit
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Mechanically ventilated
- Born at gestation 34 weeks and above
Exclusion Criteria:
- Congenital diaphragmatic hernia
- Congenital heart disease
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Comparador activo: Ventilación limitada por presión
|
In pressure-limited ventilation arm, ventilator settings as required to maintain appropriate oxygenation and carbon-dioxide elimination. In volume-targeted ventilation arm, set target volume at 5ml/kg and wean rate. In both arms, aim to keep blood gases within normal limits. |
Comparador activo: Ventilación dirigida por volumen
|
In pressure-limited ventilation arm, ventilator settings as required to maintain appropriate oxygenation and carbon-dioxide elimination. In volume-targeted ventilation arm, set target volume at 5ml/kg and wean rate. In both arms, aim to keep blood gases within normal limits. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Duration of mechanical ventilation
Periodo de tiempo: For each patient, the exact number of hours from the date and time of randomisation to the date and time of successful removal of the endotracheal tube, assessed up to 4 weeks.
|
Data will be collected from the intensive care observation chart to determine the time at which the infant was successfully taken off of mechanical ventilation, assessed up to 4 weeks.
|
For each patient, the exact number of hours from the date and time of randomisation to the date and time of successful removal of the endotracheal tube, assessed up to 4 weeks.
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Anne Greenough, MD, King's College Hospital NHS Trust
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 07/H0808/147-3
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .