- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT02461862
Vital Signs and Pain During Insertion of IUD
Assessment of Vital Signs and Pain During Insertion of Intra Uterine Device
Descripción general del estudio
Estado
Condiciones
Descripción detallada
The intrauterine device (IUD), which is one of the most effective and safe contraceptives is still little used by women. It is considered a long action reversible contraception (LARC). Among the many reasons for this resistance stands the fear of pain, the complications that can occur during the insertion.
Objective: To evaluate the intensity of pain on outpatient insertion of IUD. In addition to evaluating changes in vital signs and detect which are the factors associated with pain on outpatient insertion of IUD. Methods: Cross Sectional Retrospective study of 285 procedures of outpatient insertion of IUD.
Inclusion criteria were age older than 18 years, cervical cytology without abnormalities, classification for Category 1 or 2 of the WHO eligibility criteria for IUD. The criteria for non inclusion were patients with cardiac arrhythmias and gynecological disorders. The insertions of IUD were conducted on an outpatient basis without the use of painkillers.
Evaluation of vital signs ( blood pressure and radial pulse) was performed pre and five minutes after the procedure. The pain assessment was performed using the scale visual analog (VAS), five minutes after the procedure.Correlations of the pain's score with clinical factors as age, parity, BMI, hysterometry, previous vaginal delivery were also performed.
Tipo de estudio
Inscripción (Actual)
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- age older than 18 years
- cytology without abnormalities
- classification for Category 1 or 2 of the WHO eligibility criteria for IUD / IUS.
Exclusion Criteria:
- patients with cardiac arrhythmias
- gynecological disorders
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Intra Uternine Device
Women who came to the medical service, to insert an intra uterine Device (IUD) of Cu or a Levonorgestrel Intra Uterine System( Lng- IUS) after have been attended in the Family Planning Service of Federal University of São Paulo .
All patient have had the pain evaluated by Application of the Visual Analog Scale of Pain (VAS), and also their vital signs ( Evaluation of blood pressure,Evaluation of radial pulse) evaluated pre and five minutes after the IUD/ IUS insertion.
|
Evaluation of pain previous and 5 minutes after outpatient insertion of IUD / IUS using the Visual Analog Scale of Pain
Otros nombres:
Evaluation of Blood pressure ( mmHg), previous and 5 minutes after outpatient insertion of IUD / IUS by sphygmomanometer.
Otros nombres:
Evaluation of radial pulse (beats per minute) previous and 5 minutes after outpatient insertion of IUD / IUS by pulse oximetry
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Evaluation of pain after insertion of IUD/IUS
Periodo de tiempo: Single evaluation after 5 minutes of the insertion of the IUD/IUS ( the evaluation takes 1 minute- choose a number on visual analog scale of pain that represents the pain of that moment
|
Assessment of pain five minutes immediately after IUD/IUS insertion using the visual analog scale - choose a number on visual analog scale of pain that represents the pain of that moment
|
Single evaluation after 5 minutes of the insertion of the IUD/IUS ( the evaluation takes 1 minute- choose a number on visual analog scale of pain that represents the pain of that moment
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Evaluation of blood pressure modification after insertion of IUD/IUS
Periodo de tiempo: Duration 15 minutes - two evaluations: before the procedure and five minutes immediately after IUD/IUS insertion
|
Evaluation of blood pressure (mmHg) using a Sphygmomanometer, before and five minutes after the insertion of the IUD/IUS
|
Duration 15 minutes - two evaluations: before the procedure and five minutes immediately after IUD/IUS insertion
|
|
Evaluation of clinical factors that may interfere with the intensity of pain
Periodo de tiempo: 1 day
|
Correlate the pain score of VAS with clinical factors as age, parity, BMI, hysterometry, previous vaginal delivery
|
1 day
|
|
Evaluation of radial pulse modification after insertion of IUD/IUS
Periodo de tiempo: Duration 15 minutes - two evaluations: before the procedure and five minutes immediately after IUD/IUS insertion
|
Evaluation of radial pulse ( beats per minute) using a pulse oximeter before and five minutes after the insertion of the IUD/IUS
|
Duration 15 minutes - two evaluations: before the procedure and five minutes immediately after IUD/IUS insertion
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Silla de estudio: Zsuzsanna IK Jarmy di Bella, Federal University of São Paulo
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- Nº CEP: 0272/2015
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .