Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Treatment Based on High Precision Cardiac Mapping (APOLO-VT)

24 de agosto de 2026 actualizado por: Ivo Roca, Hospital Clinic of Barcelona

Treatment Based on High Precision Cardiac Mapping: Advancing Personalized Outcomes Through Optimized Localization

APOLO-VT aims to evaluate the feasibility, safety, and clinical impact of an integrated multimodal mapping workflow combining non-invasive structural and functional substrate characterization using Volumetric Electrocardiographic Imaging (ECGi) with invasive Electroanatomical Mapping (EAM) to support Ventricular tachycardia (VT) ablation targeting and verification.

Descripción general del estudio

Tipo de estudio

Intervencionista

Inscripción (Estimado)

60

Fase

  • Fase 4

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Barcelona, España, 08036
        • Reclutamiento
        • Hospital Clinic, University of Barcelona
        • Contacto:
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion criteria

  • Age ≥18 years.
  • Diagnosis of structural heart disease (ischemic or non-ischemic cardiomyopathy).
  • Documented sustained monomorphic VT (clinical or inducible), or recurrent ICD therapies for VT.
  • Scheduled for catheter ablation of VT according to current international guidelines.
  • Ability to provide written informed consent.
  • Ability to remain upright or seated to allow a video for 3D torso reconstruction for ECGi acquisition.

Exclusion criteria

  • Age <18 years.
  • Pregnant or breastfeeding women.
  • Inability to provide informed consent due to physical or mental condition.
  • Contraindication to computed tomography or cardiac magnetic resonance (magnetic resonance imaging-incompatible devices, claustrophobia).
  • Contraindication to contrast agents (gadolinium allergy or severe renal dysfunction with estimated glomerular filtration rate <30 mL/min/1.73 m²).
  • Inability to remain upright for torso 3D reconstruction required for ECGi.
  • Life expectancy <1 year due to non-cardiac comorbidity.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Ablation strategy
Ablation is guided by an integrated non-invasive mapping strategy, combining structural targets from late gadolinium enhancement cardiac magnetic resonance and/or functional targets (deceleration zones) from non-invasive Volumetric ECGi in sinus rhythm (SR) and pacing protocol; both are merged with invasive electroanatomic mapping. Before ablation, programmed stimulation assesses VT inducibility; if VT is induced, its Volumetric ECGi-derived critical isthmus is added as a further target. Lesions are delivered to these non-invasively defined target regions, with adequacy defined as loss of local capture on pacing at the ablation site. Afterwards, SR and paced Volumetric ECGi remapping reassesses residual deceleration zones, with further ablation and remapping if substrate persists. Programmed stimulation is repeated, with invasive remapping and ablation for validation. Acute procedural success requires VT non-inducibility and elimination of relevant functional substrate.
ADAS 3D (ADAS 3D Medical, Barcelona; CE 714517) and the ACORYS Mapping System (Corify Care SL, Madrid; CE 775709) are two independently operating, CE-marked devices used within their approved intended use. ADAS 3D processes cardiac magnetic resonance images to characterize myocardial scar, border zone, and conduction corridors. ACORYS performs non-invasive electrocardiographic mapping, importing the ADAS 3D-derived anatomy to contextualize its electrophysiological maps. The structural and functional information from both devices is reviewed by the treating electrophysiologist as decision-support information, alongside invasive electroanatomic mapping; the ablation strategy and all treatment decisions remain at the physician's clinical discretion.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
VT recurrence
Periodo de tiempo: 12 months
Recurrence of sustained ventricular tachycardia after the index ablation.
12 months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Acute procedural outcomes
Periodo de tiempo: Baseline
Rate of acute procedural success, defined as non-inducibility of sustained monomorphic ventricular tachycardia and absence of relevant residual deceleration zones on post-ablation remapping. Procedural efficiency (procedure duration, fluoroscopy time, radiofrequency application time).
Baseline
Procedure complications
Periodo de tiempo: Baseline
Acute and late complications related to ablation (vascular complications, tamponade, stroke, and mortality) as well as late complications (pericarditis, phrenic nerve injury, device-related events)
Baseline
Electrophysiological endpoints
Periodo de tiempo: Baseline
Correlation between non-invasive structural and functional targets (defined by the APOLO-VT ablation strategy) and invasive electrogram characteristics (low-voltage zones, fractionated or late potentials). Assessment of whether these non-invasive targets predict VT inducibility after ablation.
Baseline
Clinical outcomes during follow-up
Periodo de tiempo: 12 months
Effect of the APOLO-VT ablation strategy on ICD therapies, heart failure hospitalization, and all-cause mortality during follow-up.
12 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

15 de julio de 2026

Finalización primaria (Estimado)

31 de diciembre de 2027

Finalización del estudio (Estimado)

31 de diciembre de 2028

Fechas de registro del estudio

Enviado por primera vez

20 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

31 de julio de 2026

Publicado por primera vez (Actual)

5 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

25 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

24 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • APOLO-VT

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir