- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07861659
Clinical Evaluation of 3D-Printed Versus Direct Composite Restorations in Class II Cavities
The aim of this study is to clinically evaluate the performance of 3D-printed composites compared to direct conventional composite restorations in Class II cavities
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Resin-based composites are widely used for posterior restorations because of their esthetics, adhesion, and conservative preparation. However, Class II restorations remain challenging due to polymerization shrinkage, marginal gaps, postoperative sensitivity, and inadequate proximal contacts. Digital additive manufacturing has emerged as a promising approach, offering precise fabrication, reduced material waste, and customizable restorations. Although laboratory studies suggest favorable mechanical properties and marginal adaptation, clinical evidence for 3D-printed intracoronal restorations remains limited. Therefore, this randomized clinical trial will compare the clinical performance of 3D-printed composite inlays with conventional direct composite restorations in Class II cavities over 24 months.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Egypt
-
Tanta, Egypt, Egipto, 31511
- aculty of Dentistry, Tanta University, Tanta, Tanta 31527
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Have at least two Class II carious lesions corresponded to ICDAS scores 4 and 5, representing dentinal caries suitable for operative restorative treatment.
- The absence of ongoing orthodontic treatment or use of prostheses.
- Good general health without relevant disease.
Exclusion Criteria:
- Uncooperative patient.
- Any parafunctional habits such as tooth clenching or grinding.
- Chronic pulmonary diseases and blocked nasal passages.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Otro
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: 3D-Printed Composite Inlays
Participants will receive Class II restorations fabricated from a commercially available 3D-printable permanent composite resin using a standardized digital workflow. The restorations will be adhesively bonded to the prepared cavities according to the manufacturer's instructions. |
Class II cavities will be restored with digitally designed and 3D-printed permanent composite inlays. The restorations will be post-cured and adhesively cemented according to the material manufacturer's recommendations |
|
Comparador activo: Direct Composite Restorations
Participants will receive conventional direct Class II restorations using a commercially available resin-based composite. Restorations will be placed incrementally using a standardized adhesive protocol and light-curing procedure according to the manufacturer's recommendations. Both groups will be clinically evaluated at baseline and during the 18-month follow-up period using standardized clinical criteria. |
Class II cavities will be restored directly using a conventional light-cured resin-based composite placed with a standardized incremental technique and adhesive protocol |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Fracture and retention
Periodo de tiempo: 18 months
|
Description: Clinical evaluation of fracture and retentin was conducted in accordance with the World Dental Federation (FDI) criteria by two calibrated examiners at baseline and after 6, 12, and 18 months. Each restoration was evaluated according to the degree of conformity with the established criteria as follows: score 1, excellent; scores 2 and 3, satisfactory; and scores 4 and 5, inadequate. Scores of 1-3 were considered indicative of clinical success, whereas scores of 4 or 5 were considered indicative of failure. |
18 months
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Balestra D, Lowther M, Goracci C, Mandurino M, Cortili S, Paolone G, Louca C, Vichi A. 3D Printed Materials for Permanent Restorations in Indirect Restorative and Prosthetic Dentistry: A Critical Review of the Literature. Materials (Basel). 2024 Mar 18;17(6):1380. doi: 10.3390/ma17061380.
- Duarte S Jr, Phark JH. Advances in Dental Restorations: A Comprehensive Review of Machinable and 3D-Printed Ceramic-Reinforced Composites. J Esthet Restor Dent. 2025 Jan;37(1):257-276. doi: 10.1111/jerd.13371. Epub 2024 Nov 18.
- Tanaka LEB, da Silva Rodrigues C, Grangeiro MTV, Campos TMB, de Melo RM. Characterization of 3D printed composite for final dental restorations. Clin Oral Investig. 2024 Oct 31;28(11):617. doi: 10.1007/s00784-024-06003-8.
- Peskersoy C, Oguzhan A. Evaluation of the Mechanical and Adhesion Characteristics of Indirect Restorations Manufactured with Three-Dimensional Printing. Polymers (Basel). 2024 Feb 23;16(5):613. doi: 10.3390/polym16050613.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 3D-Printed & Direct Composite
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .