Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy

sunnuntai 28. kesäkuuta 2026 päivittänyt: Rania Fathy Mohammed Mohammed, Cairo University

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy :(A Randomized Clinical Trial)

Preserving primary teeth is essential for maintaining normal chewing, speech development, and psychological well-being. Successful pulpectomy depends on effective chemomechanical preparation of the root canals while preserving their original anatomy. Although hand files are traditionally used for canal preparation in primary teeth, they are time-consuming and may increase the risk of procedural errors. Nickel-titanium (Ni-Ti) rotary systems have gained popularity because they improve canal shaping and reduce instrumentation time. Among these systems, Pediatric NiTi rotary files manufactured with AF-H Wire technology and Pediatric NiTi rotary files manufactured with blue Wire technology are specifically designed for pediatric use. However, evidence regarding their clinical performance remains limited, highlighting the need to compare their effectiveness, particularly in terms of instrumentation time and obturation quality

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

30

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Lapsi

Hyväksyy terveitä vapaaehtoisia

Joo

Kuvaus

Inclusion Criteria:

  1. Healthy Cooperative children.
  2. Children between the ages of four and eight years.
  3. Restorable teeth with irreversible pulpitis.
  4. Continuous bleeding after amputation of coronal pulp tissue.

Exclusion Criteria:

  1. Molars that exhibit physiologic root resorption in excess of one-third.
  2. Internal and external root resorption.
  3. Presence of dental abscess, sinus tract or excessive mobility.
  4. Acute spreading infection/cellulitis not manageable with local treatment.
  5. Large periapical/furcation lesion with poor prognosis.
  6. Teeth close to natural exfoliation.
  7. Children with known allergies to study materials or medications used.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Kaksinkertainen

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Active Comparator: Pediatric NiTi rotary files manufactured with AF-H Wire technology
Pediatric NiTi rotary files manufactured with AF-H Wire technology are designed to improve flexibility and cyclic fatigue resistance while facilitating efficient canal preparation. Clinical studies have reported significantly reduced instrumentation time using this rotary system compared with conventional hand instrumentation. Furthermore, the system has demonstrated favorable canal shaping ability and a high percentage of optimally obturated canals, indicating its effectiveness in pediatric pulpectomy procedures
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using pediatric NiTi rotary files manufactured with AF-H Wire technology with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex and zinc oxide eugenol, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.
Kokeellinen: Pediatric NiTi rotary files manufactured with blue wire technology
Pediatric NiTi rotary files manufactured with blue wire technology are a newer pediatric rotary system developed using blue heat-treated NiTi technology. Heat treatment enhances flexibility, resistance to cyclic fatigue, and fracture resistance, which are important characteristics when preparing the curved canals of primary teeth. Laboratory studies have shown that blue wire pediatric rotary files exhibit excellent mechanical properties and superior cyclic fatigue resistance compared with several other pediatric rotary systems. However, clinical evidence evaluating its performance in terms of instrumentation efficiency and obturation quality remains limited.
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using blue technology wire rotary files with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
instumentation time
Aikaikkuna: same visit while performing the pulpectomy
The total instrumentation time will be recorded from the start of the procedure until the canals are fully prepared. Timing will begin with the insertion of the first file and will end after the final irrigation. It will be measured in minutes using a stopwatch
same visit while performing the pulpectomy

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
obturation quality
Aikaikkuna: same visit after pulpectomy completion

The quality of obturation will be evaluated according to the criteria of Coll and Sadrian criteria (1996). The apical seal will measured in millimeters from the apical end of the canal filling material to the radiographic apex and scored as 1, 2, or 3.

  1. Apical seal

    • Score 1 (Underfilling): was defined as filling in all canals extending more than 2 mm short of the apex.
    • Score 2 (Ideal filling) was considered when the material reached up to 2 mm short of the radiographic apex or reached the working length in one or more canals.
    • Score 3 (Overfilling) was recorded when the obturating material extended beyond the radiographic apex.
  2. Voids Obturated canals will be assessed for the presence or absence of voids.
same visit after pulpectomy completion

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Sponsori

Tutkijat

  • Opintojohtaja: Sara A. Mahmoud, Professor, Cairo University

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Tiistai 1. syyskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Tiistai 1. kesäkuuta 2027

Opintojen valmistuminen (Arvioitu)

Keskiviikko 1. syyskuuta 2027

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Lauantai 20. kesäkuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Keskiviikko 24. kesäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Maanantai 29. kesäkuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Keskiviikko 1. heinäkuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Sunnuntai 28. kesäkuuta 2026

Viimeksi vahvistettu

Maanantai 1. kesäkuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa