Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy

28 czerwca 2026 zaktualizowane przez: Rania Fathy Mohammed Mohammed, Cairo University

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy :(A Randomized Clinical Trial)

Preserving primary teeth is essential for maintaining normal chewing, speech development, and psychological well-being. Successful pulpectomy depends on effective chemomechanical preparation of the root canals while preserving their original anatomy. Although hand files are traditionally used for canal preparation in primary teeth, they are time-consuming and may increase the risk of procedural errors. Nickel-titanium (Ni-Ti) rotary systems have gained popularity because they improve canal shaping and reduce instrumentation time. Among these systems, Pediatric NiTi rotary files manufactured with AF-H Wire technology and Pediatric NiTi rotary files manufactured with blue Wire technology are specifically designed for pediatric use. However, evidence regarding their clinical performance remains limited, highlighting the need to compare their effectiveness, particularly in terms of instrumentation time and obturation quality

Przegląd badań

Typ studiów

Interwencyjne

Zapisy (Szacowany)

30

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dziecko

Akceptuje zdrowych ochotników

Tak

Opis

Inclusion Criteria:

  1. Healthy Cooperative children.
  2. Children between the ages of four and eight years.
  3. Restorable teeth with irreversible pulpitis.
  4. Continuous bleeding after amputation of coronal pulp tissue.

Exclusion Criteria:

  1. Molars that exhibit physiologic root resorption in excess of one-third.
  2. Internal and external root resorption.
  3. Presence of dental abscess, sinus tract or excessive mobility.
  4. Acute spreading infection/cellulitis not manageable with local treatment.
  5. Large periapical/furcation lesion with poor prognosis.
  6. Teeth close to natural exfoliation.
  7. Children with known allergies to study materials or medications used.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Podwójnie

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Pediatric NiTi rotary files manufactured with AF-H Wire technology
Pediatric NiTi rotary files manufactured with AF-H Wire technology are designed to improve flexibility and cyclic fatigue resistance while facilitating efficient canal preparation. Clinical studies have reported significantly reduced instrumentation time using this rotary system compared with conventional hand instrumentation. Furthermore, the system has demonstrated favorable canal shaping ability and a high percentage of optimally obturated canals, indicating its effectiveness in pediatric pulpectomy procedures
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using pediatric NiTi rotary files manufactured with AF-H Wire technology with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex and zinc oxide eugenol, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.
Eksperymentalny: Pediatric NiTi rotary files manufactured with blue wire technology
Pediatric NiTi rotary files manufactured with blue wire technology are a newer pediatric rotary system developed using blue heat-treated NiTi technology. Heat treatment enhances flexibility, resistance to cyclic fatigue, and fracture resistance, which are important characteristics when preparing the curved canals of primary teeth. Laboratory studies have shown that blue wire pediatric rotary files exhibit excellent mechanical properties and superior cyclic fatigue resistance compared with several other pediatric rotary systems. However, clinical evidence evaluating its performance in terms of instrumentation efficiency and obturation quality remains limited.
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using blue technology wire rotary files with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
instumentation time
Ramy czasowe: same visit while performing the pulpectomy
The total instrumentation time will be recorded from the start of the procedure until the canals are fully prepared. Timing will begin with the insertion of the first file and will end after the final irrigation. It will be measured in minutes using a stopwatch
same visit while performing the pulpectomy

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
obturation quality
Ramy czasowe: same visit after pulpectomy completion

The quality of obturation will be evaluated according to the criteria of Coll and Sadrian criteria (1996). The apical seal will measured in millimeters from the apical end of the canal filling material to the radiographic apex and scored as 1, 2, or 3.

  1. Apical seal

    • Score 1 (Underfilling): was defined as filling in all canals extending more than 2 mm short of the apex.
    • Score 2 (Ideal filling) was considered when the material reached up to 2 mm short of the radiographic apex or reached the working length in one or more canals.
    • Score 3 (Overfilling) was recorded when the obturating material extended beyond the radiographic apex.
  2. Voids Obturated canals will be assessed for the presence or absence of voids.
same visit after pulpectomy completion

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Dyrektor Studium: Sara A. Mahmoud, Professor, Cairo University

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 września 2026

Zakończenie podstawowe (Szacowany)

1 czerwca 2027

Ukończenie studiów (Szacowany)

1 września 2027

Daty rejestracji na studia

Pierwszy przesłany

20 czerwca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

24 czerwca 2026

Pierwszy wysłany (Rzeczywisty)

29 czerwca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

1 lipca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

28 czerwca 2026

Ostatnia weryfikacja

1 czerwca 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj