Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy

28 de junho de 2026 atualizado por: Rania Fathy Mohammed Mohammed, Cairo University

Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy :(A Randomized Clinical Trial)

Preserving primary teeth is essential for maintaining normal chewing, speech development, and psychological well-being. Successful pulpectomy depends on effective chemomechanical preparation of the root canals while preserving their original anatomy. Although hand files are traditionally used for canal preparation in primary teeth, they are time-consuming and may increase the risk of procedural errors. Nickel-titanium (Ni-Ti) rotary systems have gained popularity because they improve canal shaping and reduce instrumentation time. Among these systems, Pediatric NiTi rotary files manufactured with AF-H Wire technology and Pediatric NiTi rotary files manufactured with blue Wire technology are specifically designed for pediatric use. However, evidence regarding their clinical performance remains limited, highlighting the need to compare their effectiveness, particularly in terms of instrumentation time and obturation quality

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho

Aceita Voluntários Saudáveis

Sim

Descrição

Inclusion Criteria:

  1. Healthy Cooperative children.
  2. Children between the ages of four and eight years.
  3. Restorable teeth with irreversible pulpitis.
  4. Continuous bleeding after amputation of coronal pulp tissue.

Exclusion Criteria:

  1. Molars that exhibit physiologic root resorption in excess of one-third.
  2. Internal and external root resorption.
  3. Presence of dental abscess, sinus tract or excessive mobility.
  4. Acute spreading infection/cellulitis not manageable with local treatment.
  5. Large periapical/furcation lesion with poor prognosis.
  6. Teeth close to natural exfoliation.
  7. Children with known allergies to study materials or medications used.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Pediatric NiTi rotary files manufactured with AF-H Wire technology
Pediatric NiTi rotary files manufactured with AF-H Wire technology are designed to improve flexibility and cyclic fatigue resistance while facilitating efficient canal preparation. Clinical studies have reported significantly reduced instrumentation time using this rotary system compared with conventional hand instrumentation. Furthermore, the system has demonstrated favorable canal shaping ability and a high percentage of optimally obturated canals, indicating its effectiveness in pediatric pulpectomy procedures
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using pediatric NiTi rotary files manufactured with AF-H Wire technology with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex and zinc oxide eugenol, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.
Experimental: Pediatric NiTi rotary files manufactured with blue wire technology
Pediatric NiTi rotary files manufactured with blue wire technology are a newer pediatric rotary system developed using blue heat-treated NiTi technology. Heat treatment enhances flexibility, resistance to cyclic fatigue, and fracture resistance, which are important characteristics when preparing the curved canals of primary teeth. Laboratory studies have shown that blue wire pediatric rotary files exhibit excellent mechanical properties and superior cyclic fatigue resistance compared with several other pediatric rotary systems. However, clinical evidence evaluating its performance in terms of instrumentation efficiency and obturation quality remains limited.
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed. Working length will be determined radiographically, and root canal preparation will be performed using blue technology wire rotary files with 1% sodium hypochlorite irrigation between files. Instrumentation time will be recorded throughout the procedure. The canals will then be dried and obturated with Metapex, followed by restoration with glass ionomer cement and a stainless steel crown. Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
instumentation time
Prazo: same visit while performing the pulpectomy
The total instrumentation time will be recorded from the start of the procedure until the canals are fully prepared. Timing will begin with the insertion of the first file and will end after the final irrigation. It will be measured in minutes using a stopwatch
same visit while performing the pulpectomy

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
obturation quality
Prazo: same visit after pulpectomy completion

The quality of obturation will be evaluated according to the criteria of Coll and Sadrian criteria (1996). The apical seal will measured in millimeters from the apical end of the canal filling material to the radiographic apex and scored as 1, 2, or 3.

  1. Apical seal

    • Score 1 (Underfilling): was defined as filling in all canals extending more than 2 mm short of the apex.
    • Score 2 (Ideal filling) was considered when the material reached up to 2 mm short of the radiographic apex or reached the working length in one or more canals.
    • Score 3 (Overfilling) was recorded when the obturating material extended beyond the radiographic apex.
  2. Voids Obturated canals will be assessed for the presence or absence of voids.
same visit after pulpectomy completion

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Diretor de estudo: Sara A. Mahmoud, Professor, Cairo University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de setembro de 2026

Conclusão Primária (Estimado)

1 de junho de 2027

Conclusão do estudo (Estimado)

1 de setembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

20 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

24 de junho de 2026

Primeira postagem (Real)

29 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

1 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

28 de junho de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever