Reduction of blood loss in primary hip arthroplasty with tranexamic acid or fibrin spray

Jamie S McConnell, Sandeep Shewale, Niall A Munro, Kalpesh Shah, Angela H Deakin, Andrew W G Kinninmonth, Jamie S McConnell, Sandeep Shewale, Niall A Munro, Kalpesh Shah, Angela H Deakin, Andrew W G Kinninmonth

Abstract

Background and purpose: Previous studies have shown that either fibrin spray or tranexamic acid can reduce blood loss at total hip replacement, but the 2 treatments have not been directly compared. We therefore conducted a randomized, controlled trial.

Patients and methods: In this randomized controlled trial we compared the effect of tranexamic acid and fibrin spray on blood loss in cemented total hip arthroplasty. 66 patients were randomized to 1 of 3 parallel groups receiving (1) a 10 mg/kg bolus of tranexamic acid prior to surgery, (2) 10 mL of fibrin spray during surgery, or (3) neither. All participants except the surgeon were blinded as to treatment group until data analysis was complete. Blood loss was calculated from preoperative and postoperative hematocrit.

Results: Neither active treatment was found to be superior to the other in terms of overall blood loss. Losses were lower than those in the control group, when using either tranexamic acid (22% lower, p = 0.02) or fibrin spray (32% lower, p = 0.02).

Interpretation: We found that the use of tranexamic acid at induction, or topical fibrin spray intraoperatively, reduced blood loss compared to the control group. Blood loss was similar in the fibrin spray group and in the tranexamic acid group. ClinicalTrials.gov identifier: NCT00378872. EudraCT identifier: 2006-001299-19. Regional Ethics Committee approval: 06/S0703/55, granted June 6, 2006.

Figures

https://www.ncbi.nlm.nih.gov/pmc/articles/instance/3247881/bin/ORT-0300-9734-082-660_g001.jpg
Box plot of blood loss for each of the study groups (in mL), showing median, interquartile range (box), 5 and 95 percentiles (whiskers), and outliers.

References

    1. Benoni G, Lethagen S, Nilsson P, Fredin H. Tranexamic acid, given at the end of the operation, does not reduce postoperative blood loss in hip arthroplasty. Acta Orthop Scand. 2000;71(3):250–4.
    1. Benoni G, Fredin H, Knebel R, Nilsson P. Blood conservation with tranexamic acid in total hip arthroplasty: a randomized, double-blind study in 40 primary operations. Acta Orthop Scand. 2001;72(5):442–44.
    1. Claeys MA, Vermeersch N, Haentjens P. Reduction of blood loss with tranexamic acid in primary total hip replacement surgery. Acta Chir Belg. 2007;107(4):397–401.
    1. Ekbäck G, Axelsson K, Ryttberg L, et al. Tranexamic acid reduces blood loss in total hip replacement surgery. Anesth Analg. 2000;91(5):1124–30.
    1. Garneti N, Field J. Bone bleeding during total hip arthroplasty after administration of tranexamic acid. J Arthroplasty. 2004;19(4):488–92.
    1. Ho KM, Ismail H. Use of intravenous tranexamic acid to reduce allogeneic blood transfusion in total hip and knee arthroplasty: a meta-analysis. Anaesth Intensive Care. 2003;31((5)):529–37.
    1. Husted H, Blønd L, Sonne-Holm S, Holm G, Jacobsen TW, Gebuhr P. Tranexamic acid reduces blood loss and blood transfusions in primary total hip arthroplasty: a prospective randomized double-blind study in 40 patients. Acta Orthop Scand. 2003;74(6):665–9.
    1. Ido K, Neo M, Asada Y, et al. Reduction of blood loss using tranexamic acid in total knee and hip arthroplasties. Arch Orthop Trauma Surg. 2000;120(9):518–20.
    1. Johansson T, Pettersson LG, Lisander B. Tranexamic acid in total hip arthroplasty saves blood and money: a randomized, double-blind study in 100 patients. Acta Orthop. 2005;76(3):314–9.
    1. Mawatari M, Higo T, Tsutsumi Y, Shigematsu M, Hotokebuchi T. Effectiveness of autologous fibrin tissue adhesive in reducing postoperative blood loss during total hip arthroplasty: a prospective randomised study of 100 cases. J Orthop Surg (Hong Kong) 2006;14(2):117–21.
    1. Nadler SB. Prediction of blood volume in normal human adults. Surgery. 1962;52(2):224–32.
    1. Niskanen RO, Korkala OL. Tranexamic acid reduces blood loss in cemented hip arthroplasty: a randomized, double-blind study of 39 patients with osteoarthritis. Acta Orthop. 2005;76(6):829–32.
    1. Rajesparan K, Biant LC, Ahmad M, Field RE. The effect of an intravenous bolus of tranexamic acid on blood loss in total hip replacement. J Bone Joint Surg (Br) 2009;91(6):776–83.
    1. Sehat K, Evans R, Newman J. Hidden blood loss following hip and knee arthroplasty. Correct management of blood loss should take hidden loss into account. J Bone Joint Surg (Br) 2004;86(4):561–5.
    1. Wang GJ, Goldthwaite CA, Burks S, Crawford R, Spotnitz WD, Group OI. Fibrin sealant reduces perioperative blood loss in total hip replacement. J Long Term Eff Med Implant. 2003;13(5):399–411.

Source: PubMed

3
Tilaa