Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

Sébastien Perbet, Bruno Pereira, Florian Grimaldi, Christian Dualé, Jean-Etienne Bazin, Jean-Michel Constantin, Sébastien Perbet, Bruno Pereira, Florian Grimaldi, Christian Dualé, Jean-Etienne Bazin, Jean-Michel Constantin

Abstract

Background: Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization.

Methods/design: The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections.

Discussion: The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications.

Trial registration: ClinicalTrials.gov Identifier: NCT01888094.

Figures

Figure 1
Figure 1
CONSORT diagram of the SUBGEUS trial.
Figure 2
Figure 2
Out-of-plane view (short axis) of the needle entering the subclavian vein with the acoustic shadow in an infraclavicular approach. N, needle; SCA, subclavian artery; SCV, subclavian vein.
Figure 3
Figure 3
In-plane view (long axis) of guidewire placement in the subclavian vein using an infraclavicular approach. AV, axillary vein; GW, guidewire; Rib 1, acoustic shadow on the first rib; SCV, subclavian vein.

References

    1. Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM. Complications and failures of subclavian-vein catheterization. N Engl J Med. 1994;331:1735–1738. doi: 10.1056/NEJM199412293312602.
    1. Randolph AG, Cook DJ, Gonzales CA, Pribble CG. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med. 1996;24:2053–2058. doi: 10.1097/00003246-199612000-00020.
    1. Merrer J, Lefrant JY, Timsit JF. How to improve central venous catheter use in intensive care unit? Ann Fr Anesth Reanim. 2006;25:180–188. doi: 10.1016/j.annfar.2005.07.079.
    1. O’Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, Masur H, McCormick RD, Mermel LA, Pearson ML, Raad II, Randolph A, Weinstein RA. Healthcare Infection Control Practices Advisory Committee. Guidelines for the prevention of intravascular catheter-related infections. Infect Control Hosp Epidemiol. 2002;23:759–769. doi: 10.1086/502007.
    1. Denys BG, Uretsky BF, Reddy PS. Ultrasound-assisted cannulation of the internal jugular vein: a prospective comparison to the external landmark-guided technique. Circulation. 1993;87:1557–1562. doi: 10.1161/01.CIR.87.5.1557.
    1. Karakitsos D, Labropoulos N, De Groot E, Patrianakos AP, Kouraklis G, Poularas J, Samonis G, Tsoutsos DA, Konstadoulakis MM, Karabinis A. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care. 2006;10:R162. doi: 10.1186/cc5101.
    1. Fragou M, Gravvanis A, Dimitriou V, Papalois A, Kouraklis G, Karabinis A, Saranteas T, Poularas J, Papanikolaou J, Davlouros P, Labropoulos N, Karakitsos D. Real-time ultrasound-guided subclavian vein cannulation versus the landmark method in critical care patients: a prospective randomized study. Crit Care Med. 2011;39:1607–1612. doi: 10.1097/CCM.0b013e318218a1ae.
    1. Maury E, Guglielminotti J, Alzieu M, Guidet B, Offenstadt G. Ultrasonic examination: an alternative to chest radiography after central venous catheter insertion? Am J Respir Crit Care Med. 2001;164:403–405. doi: 10.1164/ajrccm.164.3.2009042.
    1. Czepizak CA, O’Callaghan JM, Venus B. Evaluation of formulas for optimal positioning of central venous catheters. Chest. 1995;107:1662–1664. doi: 10.1378/chest.107.6.1662.
    1. Aslamy Z, Dewald CL, Heffner JE. MRI of central venous anatomy: implications for central venous catheter insertion. Chest. 1998;114:820–826. doi: 10.1378/chest.114.3.820.
    1. Bertini P, Frediani M. Ultrasound guided supraclavicular central vein cannulation in adults: a technical report. J Vasc Access. 2013;14:89–93. doi: 10.5301/jva.5000088.
    1. Shiloh AL, Eisen LA, Yee M, Langner JB, LeDonne J, Karakitsos D. Ultrasound-guided subclavian and axillary vein cannulation via an infraclavicular approach: in the tradition of Robert Aubaniac. Crit Care Med. 2012;40:2922–2923. doi: 10.1097/CCM.0b013e31825cea64.
    1. Sommerkamp SK, Romaniuk VM, Witting MD, Ford DR, Allison MG, Euerle BD. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation. Am J Emerg Med. 2013;31:478–481. doi: 10.1016/j.ajem.2012.09.015.
    1. Bodenham AR. Ultrasound-guided subclavian vein catheterization: beyond just the jugular vein. Crit Care Med. 2011;39:1819–1820. doi: 10.1097/CCM.0b013e31821b813b.
    1. Lichtenstein DA, Menu Y. A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung Sliding Chest. 1995;108:1345–1348.
    1. Lichtenstein D, Meziere G, Biderman P, Gepner A. The comet-tail artifact: an ultrasound sign ruling out pneumothorax. Intensive Care Med. 1999;25:383–388. doi: 10.1007/s001340050862.
    1. Lichtenstein DA, Lascols N, Prin S, Meziere G. The “lung pulse”: an early ultrasound sign of complete atelectasis. Intensive Care Med. 2003;29:2187–2192. doi: 10.1007/s00134-003-1930-9.
    1. Lichtenstein D, Meziere G, Biderman P, Gepner A. The “lung point”: an ultrasound sign specific to pneumothorax. Intensive Care Med. 2000;26:1434–1440. doi: 10.1007/s001340000627.
    1. Volpicelli G, Elbarbary M, Blaivas M, Lichtenstein DA, Mathis G, Kirkpatrick AW, Melniker L, Gargani L, Noble VE, Via G, Dean A, Tsung JW, Soldati G, Copetti R, Bouhemad B, Reissig A, Agricola E, Rouby JJ, Arbelot C, Liteplo A, Sargsyan A, Silva F, Hoppmann R, Breitkreutz R, Seibel A, Neri L, Storti E, Petrovic T. International Liaison Committee on Lung Ultrasound (ILC-LUS) for International Consensus Conference on Lung Ultrasound (ICC-LUS) International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38:577–591. doi: 10.1007/s00134-012-2513-4.
    1. Perbet S, Longeras F, Duchenne J, Constantin JM, Bazin JE. Interest of contrast test during ultrasound-guided reposition of a malpositioned venous sub-clavian central catheter. Ann Fr Anesth Reanim. 2009;28:1031–1032. doi: 10.1016/j.annfar.2009.10.005.
    1. Vezzani A, Brusasco C, Palermo S, Launo C, Mergoni M, Corradi F. Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: an alternative to chest radiography. Crit Care Med. 2010;38:533–538. doi: 10.1097/CCM.0b013e3181c0328f.
    1. Bout H, Gibert S, Arbelot C, Ouragini H, Bouhemad B, Rouby J-J. Valeur de l’échographie dans le contrôle du bon positionnement des cathéters veineux centraux. Ann Fr Anesth Reanim. 2008;27S:S83.
    1. Royston H. Multiple imputation of missing values. Stata J. 2004;4:227–241.

Source: PubMed

3
Tilaa