A clear liquid diet is not mandatory for polyethylene glycol-based bowel preparation for afternoon colonoscopy in healthy outpatients

Yoon Suk Jung, Hyo Sun Seok, Dong Il Park, Chang Seok Song, Seong Eun Kim, Suck Ho Lee, Chang Soo Eun, Dong Soo Han, Yong Soo Kim, Chang Kyun Lee, Yoon Suk Jung, Hyo Sun Seok, Dong Il Park, Chang Seok Song, Seong Eun Kim, Suck Ho Lee, Chang Soo Eun, Dong Soo Han, Yong Soo Kim, Chang Kyun Lee

Abstract

Background/aims: A dietary regimen consisting of a clear liquid diet (CLD) for at least 24 hours is recommended for colonoscopy preparation. However, this requirement results in problems in patient compliance with bowel preparation. The aim of this study was to evaluate the efficacy of a CLD compared with a regular diet (RD) for colonoscopy preparation using a polyethylene glycol (PEG) solution.

Methods: This was a multicenter, randomized, investigator-blind prospective study. A total of 801 healthy outpatients undergoing afternoon colonoscopy were randomized to either a CLD or RD in addition to a 4 L PEG regimen.

Results: The quality of bowel cleansing was not different between the CLD and RD groups in terms of the proportion with excellent or good preparation. In addition, no significant differences were observed between the two groups for polyp and adenoma detection rates and overall adverse events. Good compliance with bowel preparation was higher in the RD group than in the CLD group.

Conclusions: A CLD for a full day prior to colonoscopy should not be mandatory for PEG-based bowel preparation. Dietary education concerning the avoidance of high-fiber foods for 3 days before colonoscopy is sufficient, at least for healthy outpatients.

Keywords: Afternoon colonoscopy; Bowel preparation; Clear liquid diet; Regular diet.

Conflict of interest statement

No potential conflict of interest relevant to this article was reported.

Figures

Fig. 1
Fig. 1
Enrollment flow chart.

References

    1. Labianca R, Merelli B. Screening and diagnosis for colorectal cancer: present and future. Tumori. 2010;96:889–901.
    1. Haseman JH, Lemmel GT, Rahmani EY, Rex DK. Failure of colonoscopy to detect colorectal cancer: evaluation of 47 cases in 20 hospitals. Gastrointest Endosc. 1997;45:451–455.
    1. Gorski TF, Rosen L, Riether R, Stasik J, Khubchandani I. Colorectal cancer after surveillance colonoscopy: false-negative examination or fast growth? Dis Colon Rectum. 1999;42:877–880.
    1. Faiss S. The missed colorectal cancer problem. Dig Dis. 2011;29(Suppl 1):60–63.
    1. Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79.
    1. Froehlich F, Wietlisbach V, Gonvers JJ, Burnand B, Vader JP. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc. 2005;61:378–384.
    1. Rex DK, Petrini JL, Baron TH, et al. Quality indicators for colonoscopy. Gastrointest Endosc. 2006;63(4 Suppl):S16–S28.
    1. Davis GR, Santa Ana CA, Morawski SG, Fordtran JS. Development of a lavage solution associated with minimal water and electrolyte absorption or secretion. Gastroenterology. 1980;78(5 Pt 1):991–995.
    1. El Sayed AM, Kanafani ZA, Mourad FH, et al. A randomized single-blind trial of whole versus split-dose polyethylene glycol-electrolyte solution for colonoscopy preparation. Gastrointest Endosc. 2003;58:36–40.
    1. Aoun E, Abdul-Baki H, Azar C, et al. A randomized single-blind trial of split-dose PEG-electrolyte solution without dietary restriction compared with whole dose PEG-electrolyte solution with dietary restriction for colonoscopy preparation. Gastrointest Endosc. 2005;62:213–218.
    1. Delegge M, Kaplan R. Efficacy of bowel preparation with the use of a prepackaged, low fibre diet with a low sodium, magnesium citrate cathartic vs. a clear liquid diet with a standard sodium phosphate cathartic. Aliment Pharmacol Ther. 2005;21:1491–1495.
    1. Rapier R, Houston C. A prospective study to assess the efficacy and patient tolerance of three bowel preparations for colonoscopy. Gastroenterol Nurs. 2006;29:305–308.
    1. Church JM. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy: timing is the key! Dis Colon Rectum. 1998;41:1223–1225.
    1. Park JS, Sohn CI, Hwang SJ, et al. Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy. Endoscopy. 2007;39:616–619.
    1. Hookey LC, Depew WT, Vanner SJ. A prospective randomized trial comparing low-dose oral sodium phosphate plus stimulant laxatives with large volume polyethylene glycol solution for colon cleansing. Am J Gastroenterol. 2004;99:2217–2222.
    1. Hwang KL, Chen WT, Hsiao KH, et al. Prospective randomized comparison of oral sodium phosphate and polyethylene glycol lavage for colonoscopy preparation. World J Gastroenterol. 2005;11:7486–7493.
    1. Katsinelos P, Pilpilidis I, Paroutoglou G, et al. The administration of cisapride as an adjuvant to PEG-electrolyte solution for colonic cleansing: a double-blind randomized study. Hepatogastroenterology. 2005;52:441–443.
    1. DiPalma JA, Wolff BG, Meagher A, Cleveland M. Comparison of reduced volume versus four liters sulfate-free electrolyte lavage solutions for colonoscopy colon cleansing. Am J Gastroenterol. 2003;98:2187–2191.
    1. Sharma VK, Chockalingham SK, Ugheoke EA, et al. Prospective, randomized, controlled comparison of the use of polyethylene glycol electrolyte lavage solution in four-liter versus two-liter volumes and pretreatment with either magnesium citrate or bisacodyl for colonoscopy preparation. Gastrointest Endosc. 1998;47:167–171.
    1. Park DI, Park SH, Lee SK, et al. Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial. J Gastroenterol Hepatol. 2009;24:988–991.
    1. Scott SR, Raymond PL, Thompson WO, Galt DJ. Efficacy and tolerance of sodium phosphates oral solution after diet liberalization. Gastroenterol Nurs. 2005;28:133–139.
    1. Soweid AM, Kobeissy AA, Jamali FR, et al. A randomized single-blind trial of standard diet versus fiber-free diet with polyethylene glycol electrolyte solution for colonoscopy preparation. Endoscopy. 2010;42:633–638.
    1. Jayanthi V, Ramathilakam B, Malathi S, Dinakaran N, Balasubramanian V. Comparison of polyethylene glycol versus combination of magnesium sulphate and bisacodyl for colon preparation. Trop Gastroenterol. 2000;21:18–19.
    1. Yoon JH, Park DI, Shin JE, et al. Comparison of bowel preparation depending on completion time of polyethylene glycol ingestion and start time of colonoscopy. Intest Res. 2010;8:24–29.
    1. Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol. 2001;96:1797–1802.
    1. Kim HS, Park DH, Kim JW, et al. Effectiveness of walking exercise as a bowel preparation for colonoscopy: a randomized controlled trial. Am J Gastroenterol. 2005;100:1964–1969.

Source: PubMed

3
Tilaa