Correlation of abdominal rSO2 with superior mesenteric artery velocities in preterm infants

M Gillam-Krakauer, C M Cochran, J C Slaughter, S Polavarapu, S J McElroy, M Hernanz-Schulman, B Engelhardt, M Gillam-Krakauer, C M Cochran, J C Slaughter, S Polavarapu, S J McElroy, M Hernanz-Schulman, B Engelhardt

Abstract

Objective: Near-infrared spectroscopy (NIRS) is used to monitor brain and kidney perfusion in at-risk premature and term neonates. Although NIRS holds potential for bedside monitoring of intestinal perfusion, there is insufficient evidence showing correlation with mesenteric blood flow. To determine if an association exists between abdominal regional oxygen saturation (A-rSO2) and mesenteric blood flow, we compared changes in A-rSO2 to changes in blood flow velocity in the superior mesenteric artery (SMA) before and after feedings in very-low birthweight infants.

Study design: A-rSO2 was continuously monitored midline below the umbilicus for 3 days in 18 stable 25 to 31 week bolus-fed infants (median BW 1203 g, median age 5 days). We compared change in SMA velocity from immediately before to 10 min and 60 to 120 min after feeding with change in A-rSO2 over the same time. Spearman's rank correlation was used to ascertain if a significant association existed.

Result: Change in A-rSO2 was significantly associated with change in systolic, diastolic, and mean SMA velocity from fasting to 60 to 120 min after feeding (P=0.016, 0.021, 0.010) and from 10 min after a feed to 60 to 120 min after feeding (P=0.009, 0.035, 0.032).

Conclusion: In very preterm infants, A-rSO2 reflects blood flow in the SMA and can provide non-invasive continuous monitoring of intestinal perfusion. Further studies are indicated to determine the sensitivity of NIRS to detect early intestinal pathology in this population.

Conflict of interest statement

Conflict of Interest: Dr. Engelhardt received an unrestricted educational grant from the Somanetics Corporation (now Covidien, Boulder, CO) which was used for equipment costs. Mrs. Cochrane and Drs. Gillam-Krakauer, Polavarapu, McElroy, Slaughter and Hernanz-Schulman declare no potential conflicts of interest. Covidien had no role in the design of the study, collection, or analysis of data. They have not been provided a copy of the manuscript.

References

    1. Crissinger KD. Animal models of necrotizing enterocolitis. J Pediatr Gastroenterol Nutr. 1995;20(1):17–22.
    1. Murdoch EM, Sinha AK, Shanmugalingam ST, Smith GC, Kempley ST. Doppler flow velocimetry in the superior mesenteric artery on the first day of life in preterm infants and the risk of neonatal necrotizing enterocolitis. Pediatrics. 2006;118(5):1999–2003.
    1. Robel-Tillig E, Knupfer M, Pulzer F, Vogtmann C. Blood flow parameters of the superior mesenteric artery as an early predictor of intestinal dysmotility in preterm infants. Pediatr Radiol. 2004;34(12):958–962.
    1. Hackett GA, Campbell S, Gamsu H, Cohen-Overbeek T, Pearce JM. Doppler studies in the growth retarded fetus and prediction of neonatal necrotising enterocolitis, haemorrhage, and neonatal morbidity. Br Med J (Clin Res Ed) 1987;294(6563):13–16.
    1. Meier SD, Eble BK, Stapleton GE, Morales DL, Chang AC, Andropoulos DB. Mesenteric oxyhemoglobin desaturation improves with patent ductus arteriosus ligation. J Perinatol. 2006;26(9):562–564.
    1. Papacci P, Giannantonio C, Cota F, Latella C, Semeraro CM, Fioretti M, et al. Neonatal colour doppler ultrasound study: Normal values of abdominal blood flow velocities in the neonate during the first month of life. Pediatr Radiol. 2009;39(4):328–335.
    1. Lane AJ, Coombs RC, Evans DH, Levin RJ. Effect of feed interval and feed type on splanchnic haemodynamics. Arch Dis Child Fetal Neonatal Ed. 1998;79(1):F49–F53.
    1. Leidig E. Doppler analysis of superior mesenteric artery blood flow in preterm infants. Arch Dis Child. 1989;64(4 Spec No):476–480.
    1. Martinussen M, Brubakk AM, Vik T, Yao AC. Mesenteric blood flow velocity and its relation to transitional circulatory adaptation in appropriate for gestational age preterm infants. Pediatr Res. 1996;39(2):275–280.
    1. Van Bel F, Van Zwieten PH, Guit GL, Schipper J. Superior mesenteric artery blood flow velocity and estimated volume flow: Duplex doppler us study of preterm and term neonates. Radiology. 1990;174(1):165–169.
    1. Fang S, Kempley ST, Gamsu HR. Prediction of early tolerance to enteral feeding in preterm infants by measurement of superior mesenteric artery blood flow velocity. Arch Dis Child Fetal Neonatal Ed. 2001;85(1):F42–F45.
    1. Havranek T, Thompson Z, Carver JD. Factors that influence mesenteric artery blood flow velocity in newborn preterm infants. J Perinatol. 2006;26(8):493–497.
    1. Cortez J, Gupta M, Amaram A, Pizzino J, Sawhney M, Sood BG. Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates. J Matern Fetal Neonatal Med. 2011;24(4):574–582.
    1. Petrova A, Bhatt M, Mehta R. Regional tissue oxygenation in preterm born infants in association with echocardiographically significant patent ductus arteriosus. J Perinatol. 2011;31(7):460–464.
    1. McNeill S, Gatenby JC, McElroy S, Engelhardt B. Normal cerebral, renal and abdominal regional oxygen saturations using near-infrared spectroscopy in preterm infants. J Perinatol. 2011;31(1):51–57.
    1. Mintzer JDJ, Gardner M, Master M, Chelala M, Alpan G, LaGamma E, Parvez B. Real-time cerebral, splanchnic, and renal near-infrared spectroscopy (nirs) in very low birthweight neonates: An analysis of baseline variability. E-PAS20114521.311. 2011
    1. Mittnacht AJ. Near infrared spectroscopy in children at high risk of low perfusion. Curr Opin Anaesthesiol. 2010;23(3):342–347.

Source: PubMed