- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01730820
Influence of Preload Dependence on the Effect of Phenylephrine on Cardiac Output
The perioperative hemodynamic management aims to ensure organ perfusion pressure and an oxygen arterial transport adapted to oxygen consumption. Phenylephrine is the α-adrenergic agonist widely used during anesthesia for arterial pressure control.
Several questions on phenylephrine global and regional hemodynamics effects remain unresolved.
The investigators assume that Phenylephrine may decrease cardiac output by increasing the afterload, while most likely could also make an increase or a stability of cardiac output by action on the venous return. The investigators propose an observational study assessing the influence of preload dependence, defined by the values of pulse pressure variation, on the effect of phenylephrine on cardiac output, measured beat by beat by esophageal Doppler.
The aim of the investigators work is to improve the understanding of phenylephrine action, a daily use therapeutic action, to improve the patients care.
Aperçu de l'étude
Statut
Les conditions
Type d'étude
Inscription (Anticipé)
Contacts et emplacements
Lieux d'étude
-
-
Basse Normandie
-
Caen, Basse Normandie, France, 1400
- Caen University hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Hypotension (SBP <90 mm Hg and / or MAP <60 mm Hg)
- Injection of a bolus of phenylephrine at the discretion of the anesthesiologist physician in charge of the patient.
Exclusion Criteria:
- Minor or major patient under guardianship
- Esophageal Diseases
- supra ventricular rhythm trouble
- Severe valvular
- Shunt intracardiac
- Vt <7ml/kg theoretical weight
- heart rate / respiratory rate <3.6
- Clinical hypepression of intra-abdominal
- Compliance <30 mL/cmH2O
- pulmonary hypertension, Right ventricular failure
- Spontaneous Ventilation
- Thorax open
- VG severe dysfunction (LVEF <40%)
- Prior Injection of ephedrine prior
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Perspectives temporelles: Éventuel
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
cardiac output
Délai: one year
|
Comparing cardiac output values before and after injection of a phenylephrine bolus, based on the existence of a preload dependency, defined by a measure of respiratory variation of pulse pressure greater than or equal to 13%.
|
one year
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Olivier REBET, M.D, University Hospital, Caen
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- NEO CO
- A12-D20-VOL12 (Autre identifiant: Basse Normandie FRANCE ethics committee)
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .