- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01730820
Influence of Preload Dependence on the Effect of Phenylephrine on Cardiac Output
The perioperative hemodynamic management aims to ensure organ perfusion pressure and an oxygen arterial transport adapted to oxygen consumption. Phenylephrine is the α-adrenergic agonist widely used during anesthesia for arterial pressure control.
Several questions on phenylephrine global and regional hemodynamics effects remain unresolved.
The investigators assume that Phenylephrine may decrease cardiac output by increasing the afterload, while most likely could also make an increase or a stability of cardiac output by action on the venous return. The investigators propose an observational study assessing the influence of preload dependence, defined by the values of pulse pressure variation, on the effect of phenylephrine on cardiac output, measured beat by beat by esophageal Doppler.
The aim of the investigators work is to improve the understanding of phenylephrine action, a daily use therapeutic action, to improve the patients care.
Visão geral do estudo
Status
Condições
Tipo de estudo
Inscrição (Antecipado)
Contactos e Locais
Locais de estudo
-
-
Basse Normandie
-
Caen, Basse Normandie, França, 1400
- Caen University hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Hypotension (SBP <90 mm Hg and / or MAP <60 mm Hg)
- Injection of a bolus of phenylephrine at the discretion of the anesthesiologist physician in charge of the patient.
Exclusion Criteria:
- Minor or major patient under guardianship
- Esophageal Diseases
- supra ventricular rhythm trouble
- Severe valvular
- Shunt intracardiac
- Vt <7ml/kg theoretical weight
- heart rate / respiratory rate <3.6
- Clinical hypepression of intra-abdominal
- Compliance <30 mL/cmH2O
- pulmonary hypertension, Right ventricular failure
- Spontaneous Ventilation
- Thorax open
- VG severe dysfunction (LVEF <40%)
- Prior Injection of ephedrine prior
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Perspectivas de Tempo: Prospectivo
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
cardiac output
Prazo: one year
|
Comparing cardiac output values before and after injection of a phenylephrine bolus, based on the existence of a preload dependency, defined by a measure of respiratory variation of pulse pressure greater than or equal to 13%.
|
one year
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Olivier REBET, M.D, University Hospital, Caen
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- NEO CO
- A12-D20-VOL12 (Outro identificador: Basse Normandie FRANCE ethics committee)
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .