- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01943227
Effect of Alveolar Minute Ventilation on Respiratory Gas Heat Content
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
California
-
Sacramento, California, États-Unis, 95817
- UC Davis Health System
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- age greater than 18 years
- scheduled for an elective surgical procedure with an anticipated duration of more than 2 hours requiring general anesthesia and positive pressure ventilation using an endotracheal tube
- patient status ASA 1, 2 or 3
- no significant cardio-vascular or respiratory disease
- supine surgical position
Exclusion Criteria:
- Adults unable to give primary consent
- age less than 18 years
- pregnancy
- prisoners
- pre-existing cardiac or pulmonary disease
- infusion of inotropic drugs
- positive end expiratory pressure (PEEP) requirements >8 cm H2O
- increased intra-abdominal pressure (e.g. planned surgical pneumoperitoneum or ascitis)
- intra-operative patient position other than supine
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cohorte
- Perspectives temporelles: Éventuel
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
6ml/kg
Enthalpy measured in patients receiving controlled positive pressure ventilation 6ml/kg Tidal volume. The VQm monitor samples the gas at a rate of 3 L/min, returning the analyzed gas to the circuit. As the exhaled gas passes through the analytical chamber, the temperature and humidity are measured essentially continuously (40Hz). These data are combined with pressure measurements to determine the exhaled gas volume and then the heat content (enthalpy) is calculated. |
controlled positive pressure ventilation 6ml/kg tidal volume
|
|
9ml/kg
Enthalpy measured in patients receiving controlled positive pressure ventilation 9ml/kg Tidal volume. The VQm monitor samples the gas at a rate of 3 L/min, returning the analyzed gas to the circuit. As the exhaled gas passes through the analytical chamber, the temperature and humidity are measured essentially continuously (40Hz). These data are combined with pressure measurements to determine the exhaled gas volume and then the heat content (enthalpy) is calculated. |
controlled positive pressure ventilation 9ml/kg tidal volume
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Airway Enthalpy
Délai: 12 months
|
This is a single site, prospective, non-blinded, non-randomized, non-interventional study designed to evaluate the effect of changes in alveolar minute ventilation on the measurement of respiratory heat loss (enthalpy) in Joules per minute.
|
12 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Neal Fleming, MD, PhD, Professor, Anesthesiology & Pain Medicine
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 483184
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .