- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02061241
A Comparison of Two Techniques for Choosing the Best Place to Put a Pacing Lead for Cardiac Resynchronisation Therapy (IDEAL-CRT)
Intracardiac Haemo-dynamics and Echocardiographic Assessment to Optimise Lead Placement for CRT
Cardiac resynchronisation therapy (CRT) using biventricular pacing (BiVP) is established as an effective treatment for heart failure. Unfortunately up to 45% of patients do not respond, with no improvement in symptoms or cardiac size. Reducing the proportion of non-responders has become the key research focus in CRT.
Targeting the position of the left ventricular (LV) pacing lead within the coronary vein network has previously been shown to increase the proportion of responders to CRT. Several techniques have been tried for targeting lead position, of which the best investigated are the use of speckle-tracking echocardiography to target the lead position to the site of latest mechanical activation of the left ventricle, and the use of invasive monitoring to select the pacing site at which the greatest acute haemodynamic response (AHR) to BiVP occurs. Both techniques are limited by groups of patients in whom the techniques are not possible or provide limited useful information.
The relationship between these two measures is unknown - there are no previous studies that have investigated correlation between the site of latest mechanical activation determined by echo and the site of maximal AHR. It is likely that a hybrid technique using both of these investigations might allow optimal lead positioning in more patients, or that if the information is shown to be equivalent, more streamlined techniques can be designed.
This study will also be able to contribute towards several important secondary questions. In particular the investigators will study the possibility of using non-invasive cardiac output monitoring (NICOM) to assess haemodynamic response rather than an intravascular pressure monitor wire. The investigators also wish to assess whether the site of latest mechanical activation is changed by right ventricular pacing.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Oxfordshire
-
Oxford, Oxfordshire, Royaume-Uni, OX3 7AT
- Oxford University Hospitals NHS Trust
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- With ejection fraction <35%
- Participant is willing and able to give informed consent for participation in the study.
- Male or Female, aged 18 years or above.
- Indication for cardiac resynchronisation therapy
Exclusion Criteria:
- Left Ventricular Ejection Fraction >35%
- Severe peripheral vascular disease (that would make arterial access more risky)
- Haemodynamic instability (such that a longer procedure is inadvisable)
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Patients
All included patients, having CRT implant procedure Will have both Pacing in vein at site of latest mechanical activation and Pacing in other suitable vein.
|
Pacing in vein at site of latest mechanical activation
Pacing in other suitable vein
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Acute haemodynamic response in area of latest mechanical activation and another vein
Délai: Time 0 (during implant procedure)
|
To assess whether pacing at the site of latest mechanical activation produces the maximal acute haemodynamic response to biventricular pacing, when compared to other attainable Left Ventricular coronary venous pacing sites. Acute haemodynamic response measured as percentage change in left ventricular dP/dt max (maximum rate of change of left ventricular pressure) recorded by a left ventricular pressure wire, between baseline atrial pacing at 80 beats per minute and biventricular pacing in each vein |
Time 0 (during implant procedure)
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Maximum acute haemodynamic response between all available pacing vectors in the vein within the area of latest mechanical response
Délai: Time 0 (during implant procedure)
|
To assess if further increases in acute haemodynamic response at the site of latest mechanical activation can be achieved with different pacing configurations.
|
Time 0 (during implant procedure)
|
|
Acute haemodynamic response by NICOM and pressure wire
Délai: Time 0 (during implant procedure)
|
To compare results attained from non-invasive cardiac output monitoring (NICOM) to those from invasive monitoring
|
Time 0 (during implant procedure)
|
|
Area of latest mechanical activation in right ventricular pacing and intrinsic rhythm
Délai: 1 day post procedure
|
To assess the effect of right ventricular pacing on the site of latest mechanical activation.
Assessed using speckle-tracking echocardiography.
|
1 day post procedure
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Tim R Betts, MBChB, MD, Oxford University Hospitals
Publications et liens utiles
Publications générales
- McAlister FA, Ezekowitz J, Hooton N, Vandermeer B, Spooner C, Dryden DM, Page RL, Hlatky MA, Rowe BH. Cardiac resynchronization therapy for patients with left ventricular systolic dysfunction: a systematic review. JAMA. 2007 Jun 13;297(22):2502-14. doi: 10.1001/jama.297.22.2502.
- Khan FZ, Virdee MS, Palmer CR, Pugh PJ, O'Halloran D, Elsik M, Read PA, Begley D, Fynn SP, Dutka DP. Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial. J Am Coll Cardiol. 2012 Apr 24;59(17):1509-18. doi: 10.1016/j.jacc.2011.12.030. Epub 2012 Mar 7.
- Saba S, Marek J, Schwartzman D, Jain S, Adelstein E, White P, Oyenuga OA, Onishi T, Soman P, Gorcsan J 3rd. Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial. Circ Heart Fail. 2013 May;6(3):427-34. doi: 10.1161/CIRCHEARTFAILURE.112.000078. Epub 2013 Mar 8.
- Duckett SG, Ginks M, Shetty AK, Bostock J, Gill JS, Hamid S, Kapetanakis S, Cunliffe E, Razavi R, Carr-White G, Rinaldi CA. Invasive acute hemodynamic response to guide left ventricular lead implantation predicts chronic remodeling in patients undergoing cardiac resynchronization therapy. J Am Coll Cardiol. 2011 Sep 6;58(11):1128-36. doi: 10.1016/j.jacc.2011.04.042.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- NIHR CSP 146533
- 14/SC/0148 (Autre identifiant: UK NRES)
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .