A Comparison of Two Techniques for Choosing the Best Place to Put a Pacing Lead for Cardiac Resynchronisation Therapy (IDEAL-CRT)
Intracardiac Haemo-dynamics and Echocardiographic Assessment to Optimise Lead Placement for CRT
Cardiac resynchronisation therapy (CRT) using biventricular pacing (BiVP) is established as an effective treatment for heart failure. Unfortunately up to 45% of patients do not respond, with no improvement in symptoms or cardiac size. Reducing the proportion of non-responders has become the key research focus in CRT.
Targeting the position of the left ventricular (LV) pacing lead within the coronary vein network has previously been shown to increase the proportion of responders to CRT. Several techniques have been tried for targeting lead position, of which the best investigated are the use of speckle-tracking echocardiography to target the lead position to the site of latest mechanical activation of the left ventricle, and the use of invasive monitoring to select the pacing site at which the greatest acute haemodynamic response (AHR) to BiVP occurs. Both techniques are limited by groups of patients in whom the techniques are not possible or provide limited useful information.
The relationship between these two measures is unknown - there are no previous studies that have investigated correlation between the site of latest mechanical activation determined by echo and the site of maximal AHR. It is likely that a hybrid technique using both of these investigations might allow optimal lead positioning in more patients, or that if the information is shown to be equivalent, more streamlined techniques can be designed.
This study will also be able to contribute towards several important secondary questions. In particular the investigators will study the possibility of using non-invasive cardiac output monitoring (NICOM) to assess haemodynamic response rather than an intravascular pressure monitor wire. The investigators also wish to assess whether the site of latest mechanical activation is changed by right ventricular pacing.
Panoramica dello studio
Stato
Condizioni
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Oxfordshire
-
Oxford, Oxfordshire, Regno Unito, OX3 7AT
- Oxford University Hospitals NHS Trust
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- With ejection fraction <35%
- Participant is willing and able to give informed consent for participation in the study.
- Male or Female, aged 18 years or above.
- Indication for cardiac resynchronisation therapy
Exclusion Criteria:
- Left Ventricular Ejection Fraction >35%
- Severe peripheral vascular disease (that would make arterial access more risky)
- Haemodynamic instability (such that a longer procedure is inadvisable)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Patients
All included patients, having CRT implant procedure Will have both Pacing in vein at site of latest mechanical activation and Pacing in other suitable vein.
|
Pacing in vein at site of latest mechanical activation
Pacing in other suitable vein
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Acute haemodynamic response in area of latest mechanical activation and another vein
Lasso di tempo: Time 0 (during implant procedure)
|
To assess whether pacing at the site of latest mechanical activation produces the maximal acute haemodynamic response to biventricular pacing, when compared to other attainable Left Ventricular coronary venous pacing sites. Acute haemodynamic response measured as percentage change in left ventricular dP/dt max (maximum rate of change of left ventricular pressure) recorded by a left ventricular pressure wire, between baseline atrial pacing at 80 beats per minute and biventricular pacing in each vein |
Time 0 (during implant procedure)
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Maximum acute haemodynamic response between all available pacing vectors in the vein within the area of latest mechanical response
Lasso di tempo: Time 0 (during implant procedure)
|
To assess if further increases in acute haemodynamic response at the site of latest mechanical activation can be achieved with different pacing configurations.
|
Time 0 (during implant procedure)
|
|
Acute haemodynamic response by NICOM and pressure wire
Lasso di tempo: Time 0 (during implant procedure)
|
To compare results attained from non-invasive cardiac output monitoring (NICOM) to those from invasive monitoring
|
Time 0 (during implant procedure)
|
|
Area of latest mechanical activation in right ventricular pacing and intrinsic rhythm
Lasso di tempo: 1 day post procedure
|
To assess the effect of right ventricular pacing on the site of latest mechanical activation.
Assessed using speckle-tracking echocardiography.
|
1 day post procedure
|
Collaboratori e investigatori
Collaboratori
Investigatori
- Investigatore principale: Tim R Betts, MBChB, MD, Oxford University Hospitals
Pubblicazioni e link utili
Pubblicazioni generali
- McAlister FA, Ezekowitz J, Hooton N, Vandermeer B, Spooner C, Dryden DM, Page RL, Hlatky MA, Rowe BH. Cardiac resynchronization therapy for patients with left ventricular systolic dysfunction: a systematic review. JAMA. 2007 Jun 13;297(22):2502-14. doi: 10.1001/jama.297.22.2502.
- Khan FZ, Virdee MS, Palmer CR, Pugh PJ, O'Halloran D, Elsik M, Read PA, Begley D, Fynn SP, Dutka DP. Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial. J Am Coll Cardiol. 2012 Apr 24;59(17):1509-18. doi: 10.1016/j.jacc.2011.12.030. Epub 2012 Mar 7.
- Saba S, Marek J, Schwartzman D, Jain S, Adelstein E, White P, Oyenuga OA, Onishi T, Soman P, Gorcsan J 3rd. Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial. Circ Heart Fail. 2013 May;6(3):427-34. doi: 10.1161/CIRCHEARTFAILURE.112.000078. Epub 2013 Mar 8.
- Duckett SG, Ginks M, Shetty AK, Bostock J, Gill JS, Hamid S, Kapetanakis S, Cunliffe E, Razavi R, Carr-White G, Rinaldi CA. Invasive acute hemodynamic response to guide left ventricular lead implantation predicts chronic remodeling in patients undergoing cardiac resynchronization therapy. J Am Coll Cardiol. 2011 Sep 6;58(11):1128-36. doi: 10.1016/j.jacc.2011.04.042.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- NIHR CSP 146533
- 14/SC/0148 (Altro identificatore: UK NRES)
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .