- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT03498027
Febrile Whole Blood Specimen Collection and Testing
Febrile Whole Blood Specimen Collection and Testing Protocol to Demonstrate Product Specificity for the Applied Biosystems™ Bacillus Anthracis Detection Kit
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Whole blood samples will be collected from febrile patients presenting with fever of unknown origin and flu-like syndromes. Collection sites will be advised of collection requirements specific to patient population with the goal of collecting samples form patient between the ages of 2-89 years of age. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor. Samples must be shipped to MRIGlobal or designated study site on the day of collection.
Collection sites will consent patients and collect one (1) 4 mL whole blood sample from adults and either (1) 2 mL pediatric whole blood sample or 0.5 mL whole blood sample collected in a micro collection container from pediatric patients (anticoagulant: K2EDTA or defined alternative) from each patient enrolled into the study. Patients may not be enrolled in the study more than once. Patients considered for enrollment will be logged on an enrollment log. Log must be reviewed by the site prior to considering a patient for study enrollment to confirm enrollment status. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor.
Study site will accept or reject samples based on shipping verification procedures and then process samples acceptable for testing within 24 hours of receipt. Sample testing must be performed in accordance with the Applied Biosystems™ Bacillus anthracis Detection Kit instructions for use.
At study start, study site will test whole blood samples received from collection sites daily (e.g. Tuesday, Wednesday, Thursday, and Friday) using the Applied Biosystems™ Bacillus anthracis Detection Kit. No reference testing will be required since the study is designed only to demonstrate product specificity. Samples are assumed to be negative for Bacillus anthracis. A minimum of 50, but likely 100 febrile whole blood samples will be tested at MRIGlobal.
Data generated will demonstrate product specificity when testing febrile whole blood samples.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Florida
-
Tarpon Springs, Florida, États-Unis, 33319
- Boca Biolistics
-
-
Massachusetts
-
Fall River, Massachusetts, États-Unis, 02720
- New England Center for Clinical Research
-
Franklin, Massachusetts, États-Unis, 02038
- Medical Research Network
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Inclusion criteria to be documented on data form provided.
- Fever of unknown origin
- Flu like syndrome
Age ranges of study participants is as follows:
2-15 Years of age 15-21 Years of age 22-40 Years of age >40 Years of age
La description
Inclusion Criteria:
- Fever
Exclusion Criteria:
- None
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cas uniquement
- Perspectives temporelles: Éventuel
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Data Collection
|
The TaqMan® Bacillus anthracis Detection Kit is composed of the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software, secondary interpretative software, and lyophilized reagents for the detection of gene targets for B. anthracis.
The test assay is a multiplexed assay targeting gene targets for B. anthracis, in addition to an internal positive control.
Reagents are lyophilized as a fully formulated Mastermix and are stable at room temperature for up to two years.
The kit is specifically designed for performing real-time PCR using the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software , with nucleic acids extracted from clinical specimens using Qiagen's QIAamp® Blood Midi Kit manual extraction or Roche MagNAPure automated extraction methods.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Product Specificity
Délai: 1 day
|
Data generated will demonstrate product specificity when testing whole blood samples.
|
1 day
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- MRI-2017-004/5
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .