- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT03498027
Febrile Whole Blood Specimen Collection and Testing
Febrile Whole Blood Specimen Collection and Testing Protocol to Demonstrate Product Specificity for the Applied Biosystems™ Bacillus Anthracis Detection Kit
Обзор исследования
Статус
Условия
Вмешательство/лечение
Подробное описание
Whole blood samples will be collected from febrile patients presenting with fever of unknown origin and flu-like syndromes. Collection sites will be advised of collection requirements specific to patient population with the goal of collecting samples form patient between the ages of 2-89 years of age. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor. Samples must be shipped to MRIGlobal or designated study site on the day of collection.
Collection sites will consent patients and collect one (1) 4 mL whole blood sample from adults and either (1) 2 mL pediatric whole blood sample or 0.5 mL whole blood sample collected in a micro collection container from pediatric patients (anticoagulant: K2EDTA or defined alternative) from each patient enrolled into the study. Patients may not be enrolled in the study more than once. Patients considered for enrollment will be logged on an enrollment log. Log must be reviewed by the site prior to considering a patient for study enrollment to confirm enrollment status. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor.
Study site will accept or reject samples based on shipping verification procedures and then process samples acceptable for testing within 24 hours of receipt. Sample testing must be performed in accordance with the Applied Biosystems™ Bacillus anthracis Detection Kit instructions for use.
At study start, study site will test whole blood samples received from collection sites daily (e.g. Tuesday, Wednesday, Thursday, and Friday) using the Applied Biosystems™ Bacillus anthracis Detection Kit. No reference testing will be required since the study is designed only to demonstrate product specificity. Samples are assumed to be negative for Bacillus anthracis. A minimum of 50, but likely 100 febrile whole blood samples will be tested at MRIGlobal.
Data generated will demonstrate product specificity when testing febrile whole blood samples.
Тип исследования
Регистрация (Действительный)
Контакты и местонахождение
Места учебы
-
-
Florida
-
Tarpon Springs, Florida, Соединенные Штаты, 33319
- Boca Biolistics
-
-
Massachusetts
-
Fall River, Massachusetts, Соединенные Штаты, 02720
- New England Center for Clinical Research
-
Franklin, Massachusetts, Соединенные Штаты, 02038
- Medical Research Network
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Inclusion criteria to be documented on data form provided.
- Fever of unknown origin
- Flu like syndrome
Age ranges of study participants is as follows:
2-15 Years of age 15-21 Years of age 22-40 Years of age >40 Years of age
Описание
Inclusion Criteria:
- Fever
Exclusion Criteria:
- None
Учебный план
Как устроено исследование?
Детали дизайна
- Наблюдательные модели: Только для случая
- Временные перспективы: Перспективный
Когорты и вмешательства
Группа / когорта |
Вмешательство/лечение |
|---|---|
|
Data Collection
|
The TaqMan® Bacillus anthracis Detection Kit is composed of the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software, secondary interpretative software, and lyophilized reagents for the detection of gene targets for B. anthracis.
The test assay is a multiplexed assay targeting gene targets for B. anthracis, in addition to an internal positive control.
Reagents are lyophilized as a fully formulated Mastermix and are stable at room temperature for up to two years.
The kit is specifically designed for performing real-time PCR using the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software , with nucleic acids extracted from clinical specimens using Qiagen's QIAamp® Blood Midi Kit manual extraction or Roche MagNAPure automated extraction methods.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Product Specificity
Временное ограничение: 1 day
|
Data generated will demonstrate product specificity when testing whole blood samples.
|
1 day
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- MRI-2017-004/5
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .