Whole blood samples will be collected from febrile patients presenting with fever of unknown origin and flu-like syndromes. Collection sites will be advised of collection requirements specific to patient population with the goal of collecting samples form patient between the ages of 2-89 years of age. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor. Samples must be shipped to MRIGlobal or designated study site on the day of collection.
Collection sites will consent patients and collect one (1) 4 mL whole blood sample from adults and either (1) 2 mL pediatric whole blood sample or 0.5 mL whole blood sample collected in a micro collection container from pediatric patients (anticoagulant: K2EDTA or defined alternative) from each patient enrolled into the study. Patients may not be enrolled in the study more than once. Patients considered for enrollment will be logged on an enrollment log. Log must be reviewed by the site prior to considering a patient for study enrollment to confirm enrollment status. Samples collected will be de-identified and assigned a specific study number. Study numbers and labels will be provided to collection site by the study monitor.
Study site will accept or reject samples based on shipping verification procedures and then process samples acceptable for testing within 24 hours of receipt. Sample testing must be performed in accordance with the Applied Biosystems™ Bacillus anthracis Detection Kit instructions for use.
At study start, study site will test whole blood samples received from collection sites daily (e.g. Tuesday, Wednesday, Thursday, and Friday) using the Applied Biosystems™ Bacillus anthracis Detection Kit. No reference testing will be required since the study is designed only to demonstrate product specificity. Samples are assumed to be negative for Bacillus anthracis. A minimum of 50, but likely 100 febrile whole blood samples will be tested at MRIGlobal.
Data generated will demonstrate product specificity when testing febrile whole blood samples.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
Florida
-
Tarpon Springs, Florida, Estados Unidos, 33319
- Boca Biolistics
-
-
Massachusetts
-
Fall River, Massachusetts, Estados Unidos, 02720
- New England Center for Clinical Research
-
Franklin, Massachusetts, Estados Unidos, 02038
- Medical Research Network
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Inclusion criteria to be documented on data form provided.
- Fever of unknown origin
- Flu like syndrome
Age ranges of study participants is as follows:
2-15 Years of age 15-21 Years of age 22-40 Years of age >40 Years of age
Descrição
Inclusion Criteria:
- Fever
Exclusion Criteria:
- None
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: Caso-somente
- Perspectivas de Tempo: Prospectivo
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Data Collection
|
The TaqMan® Bacillus anthracis Detection Kit is composed of the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software, secondary interpretative software, and lyophilized reagents for the detection of gene targets for B. anthracis.
The test assay is a multiplexed assay targeting gene targets for B. anthracis, in addition to an internal positive control.
Reagents are lyophilized as a fully formulated Mastermix and are stable at room temperature for up to two years.
The kit is specifically designed for performing real-time PCR using the Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument with SDS Software , with nucleic acids extracted from clinical specimens using Qiagen's QIAamp® Blood Midi Kit manual extraction or Roche MagNAPure automated extraction methods.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Product Specificity
Prazo: 1 day
|
Data generated will demonstrate product specificity when testing whole blood samples.
|
1 day
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- MRI-2017-004/5
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .