- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT04690517
Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR Wearing PPE
Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR (Cardiopulmonary Resuscitation) Wearing PPE (Personnel Protective Equipment): A Prospective Comparative Study
It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal protective equipment (PPE) have increased. In those cases, existing methods such as auscultation and chest uprising have to be limited. Quantitative waveform capnography is recommended as the gold standard for confirming correct endotracheal tube placement in the 2010 American HeartAssociation (AHA) Guidelines for Cardiopulmonary resuscitation (CPR) and Emergency Cardiovascular Care (ECC), but it has some well-known limitations in cardiac arrest patients.
Ultrasonography is a non-invasive, real-time diagnostic tool commonly used during resuscitation. Especially, tracheal ultrasonography can be performed in real-time when the tube is passed through the trachea or esophagus. Previous prospective studies revealed that tracheal ultrasonography could feasibly and rapidly confirm tracheal intubation during emergency intubation.
There have already been several studies comparing the accuracy of tracheal ultrasound and capnography, but there was no study comparing the two tools under the constraints of PPE that is essential in pandemic situations as in this study. This study aimed to determine the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR with PPE.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Anticipé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Seoul, Corée, République de, 06351
- Recrutement
- Samsung Medical Center
-
Contact:
- Sooyeon Kang, fellow
- Numéro de téléphone: 82-10-3157-4718
- E-mail: syrei3.kang@samsung.com
-
Contact:
- Hee Yoon, Professor
- Numéro de téléphone: 82-10-9933-5581
- E-mail: wildhi.yoon@samsung.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- 1. cardiopulmonary arrest patients receiving emergency intubation and CPR
- 2. patients judged to need to wear PPE according to the judgement of the clinician
Exclusion Criteria:
- 1. sign for "do not resuscitate (DNR)"
- 2. patients unable to perform tracheal ultrasound due to trauma of the site
- 3. patients unable to perform tracheal ultrasound due to oropharynx cancer
- 4. patients unable to perform tracheal ultrasound due to placement of tracheal cannula
- 5. patients not used tracheal ultrasound for checking tube placement
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Tracheal ultrasound
The patients in cardiopulmonary arrest should be performed tracheal ultrasound when tube is passed through the trachea or esophagus.
|
When checking tracheal ultrasound, several signs are used in judgements.
Direct signs include reverberation artifact and double ring sign.
Indirect sign means checking the bilateral lung sliding.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Accuracy
Délai: during intubation procedure
|
The gold standard is direct visualization using laryngoscopy.
Tracheal ultrasound is performed regardless of whether it is in real-time or not.
|
during intubation procedure
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chaise d'étude: Hee Yoon, Professor, Samsung medical center, Emergency department
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Anticipé)
Achèvement de l'étude (Anticipé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 2020-11-115
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .